Literature DB >> 10555178

Single breath-hold slice-following CSPAMM myocardial tagging.

M Stuber1, M A Spiegel, S E Fischer, M B Scheidegger, P G Danias, E M Pedersen, P Boesiger.   

Abstract

Myocardial tagging has shown to be a useful magnetic resonance modality for the assessment and quantification of local myocardial function. Many myocardial tagging techniques suffer from a rapid fading of the tags, restricting their application mainly to systolic phases of the cardiac cycle. However, left ventricular diastolic dysfunction has been increasingly appreciated as a major cause of heart failure. Subtraction based slice-following CSPAMM myocardial tagging has shown to overcome limitations such as fading of the tags. Remaining impediments to this technique, however, are extensive scanning times (approximately 10 min), the requirement of repeated breath-holds using a coached breathing pattern, and the enhanced sensitivity to artifacts related to poor patient compliance or inconsistent depths of end-expiratory breath-holds. We therefore propose a combination of slice-following CSPAMM myocardial tagging with a segmented EPI imaging sequence. Together with an optimized RF excitation scheme, this enables to acquire as many as 20 systolic and diastolic grid-tagged images per cardiac cycle with a high tagging contrast during a short period of sustained respiration.

Entities:  

Mesh:

Year:  1999        PMID: 10555178     DOI: 10.1007/bf02634597

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  17 in total

Review 1.  MRI of myocardial function: motion tracking techniques.

Authors:  E R McVeigh
Journal:  Magn Reson Imaging       Date:  1996       Impact factor: 2.546

2.  Navigator assessment of breath-hold duration: impact of supplemental oxygen and hyperventilation.

Authors:  P G Danias; M Stuber; R M Botnar; K V Kissinger; M L Chuang; W J Manning
Journal:  AJR Am J Roentgenol       Date:  1998-08       Impact factor: 3.959

3.  Adaptive correction of imaging plane position in segmented k-space cine cardiac MRI.

Authors:  M L Chuang; M H Chen; V C Khasgiwala; M V McConnell; R R Edelman; W J Manning
Journal:  J Magn Reson Imaging       Date:  1997 Sep-Oct       Impact factor: 4.813

4.  Noninvasive quantification of left ventricular rotational deformation in normal humans using magnetic resonance imaging myocardial tagging.

Authors:  M B Buchalter; J L Weiss; W J Rogers; E A Zerhouni; M L Weisfeldt; R Beyar; E P Shapiro
Journal:  Circulation       Date:  1990-04       Impact factor: 29.690

5.  Improved myocardial tagging contrast.

Authors:  S E Fischer; G C McKinnon; S E Maier; P Boesiger
Journal:  Magn Reson Med       Date:  1993-08       Impact factor: 4.668

6.  Diastolic myocardial wall stiffness of the left ventricle in chronic pressure overload.

Authors:  O M Hess; J F Lavelle; S Sasayama; W S Kemper; J Ross
Journal:  Eur Heart J       Date:  1982-08       Impact factor: 29.983

7.  Early contrast-enhanced MRI predicts late functional recovery after reperfused myocardial infarction.

Authors:  W J Rogers; C M Kramer; G Geskin; Y L Hu; T M Theobald; D A Vido; S Petruolo; N Reichek
Journal:  Circulation       Date:  1999-02-16       Impact factor: 29.690

Review 8.  Diastolic dysfunction in aortic stenosis.

Authors:  O M Hess; B Villari; H P Krayenbuehl
Journal:  Circulation       Date:  1993-05       Impact factor: 29.690

9.  Functional recovery of subepicardial myocardial tissue in transmural myocardial infarction after successful reperfusion: an important contribution to the improvement of regional and global left ventricular function.

Authors:  J Bogaert; A Maes; F Van de Werf; H Bosmans; M C Herregods; J Nuyts; W Desmet; L Mortelmans; G Marchal; F E Rademakers
Journal:  Circulation       Date:  1999 Jan 5-12       Impact factor: 29.690

10.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion.

Authors:  E A Zerhouni; D M Parish; W J Rogers; A Yang; E P Shapiro
Journal:  Radiology       Date:  1988-10       Impact factor: 11.105

View more
  32 in total

1.  Incompressible deformation estimation algorithm (IDEA) from tagged MR images.

Authors:  Xiaofeng Liu; Khaled Z Abd-Elmoniem; Maureen Stone; Emi Z Murano; Jiachen Zhuo; Rao P Gullapalli; Jerry L Prince
Journal:  IEEE Trans Med Imaging       Date:  2011-09-19       Impact factor: 10.048

2.  Torsion of the left ventricle during pacing with MRI tagging.

Authors:  Jonathan M Sorger; Bradley T Wyman; Owen P Faris; William C Hunter; Elliot R McVeigh
Journal:  J Cardiovasc Magn Reson       Date:  2003       Impact factor: 5.364

3.  Myocardial tagging with SSFP.

Authors:  Daniel A Herzka; Michael A Guttman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-02       Impact factor: 4.668

Review 4.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

Review 5.  Quantification of regional myocardial wall motion by cardiovascular magnetic resonance.

Authors:  Kai Jiang; Xin Yu
Journal:  Quant Imaging Med Surg       Date:  2014-10

6.  Strain-encoded breast MRI in phantom and ex vivo specimens with histological validation: preliminary results.

Authors:  Ahmed A Haruoni; Jakir Hossain; Riham El Khouli; Kant M Matsuda; David A Bluemke; Nael F Osman; Michael A Jacobs
Journal:  Med Phys       Date:  2012-12       Impact factor: 4.071

7.  Imaging three-dimensional myocardial mechanics using navigator-gated volumetric spiral cine DENSE MRI.

Authors:  Xiaodong Zhong; Bruce S Spottiswoode; Craig H Meyer; Christopher M Kramer; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

8.  Motion-robust, high-SNR liver fat quantification using a 2D sequential acquisition with a variable flip angle approach.

Authors:  Ruiyang Zhao; Yuxin Zhang; Xiaoke Wang; Timothy J Colgan; Jennifer L Rehm; Scott B Reeder; Kevin M Johnson; Diego Hernando
Journal:  Magn Reson Med       Date:  2020-04-03       Impact factor: 4.668

9.  Optimal configuration of respiratory navigator gating for the quantification of left ventricular strain using spiral cine displacement encoding with stimulated echoes (DENSE) MRI.

Authors:  Sean M Hamlet; Christopher M Haggerty; Jonathan D Suever; Gregory J Wehner; Kristin N Andres; David K Powell; Xiaodong Zhong; Brandon K Fornwalt
Journal:  J Magn Reson Imaging       Date:  2016-07-26       Impact factor: 4.813

Review 10.  Quantification in cardiac MRI: advances in image acquisition and processing.

Authors:  Anil K Attili; Andreas Schuster; Eike Nagel; Johan H C Reiber; Rob J van der Geest
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.