Megavoltage CT on a tomotherapy system.

K J Ruchala1, G H Olivera, E A Schloesser, T R Mackie.   

Abstract

A megavoltage computed tomography (MVCT) system was developed on the University of Wisconsin tomotherapy benchtop. This system can operate either axially or helically, and collect transmission data without any bounds on delivered dose. Scan times as low as 12 s per slice are possible, and scans were run with linac output rates of 100 MU min(-1), although the system can be tuned to deliver arbitrarily low dose rates. Images were reconstructed with clinically reasonable doses ranging from 8 to 12 cGy. These images delineate contrasts below 2% and resolutions of 3.0 mm. Thus, the MVCT image quality of this system should be sufficient for verifying the patient's position and anatomy prior to radiotherapy. Additionally, synthetic data were used to test the potential for improved MVCT contrast using maximum-likelihood (ML) reconstruction. Specifically, the maximum-likelihood expectation-maximization (ML-EM) algorithm and a transmission ML algorithm were compared with filtered backprojection (FBP). It was found that for expected clinical MVCT doses enough imaging photons are used such that little benefit is conferred by the improved noise model of ML algorithms. For significantly lower doses, some quantitative improvement is achieved through ML reconstruction. Nonetheless, the image quality at those lower doses is not satisfactory for radiotherapy verification.

Entities:  

Mesh:

Year:  1999        PMID: 10533931     DOI: 10.1088/0031-9155/44/10/316

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  41 in total

1.  Feasibility of intrafraction whole-body motion tracking for total marrow irradiation.

Authors:  Manju Sharma; Troy Dos Santos; Nikolaos P Papanikolopoulos; Susanta Kumar Hui
Journal:  J Biomed Opt       Date:  2011-05       Impact factor: 3.170

2.  Assessing the intrinsic precision of 3D/3D rigid image registration results for patient setup in the absence of a ground truth.

Authors:  Jian Wu; Martin J Murphy
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

3.  Influence of the type of imaging on the delineation process during the treatment planning.

Authors:  Weronika Jackowiak; Bartosz Bąk; Anna Kowalik; Adam Ryczkowski; Małgorzata Skórska; Małgorzata Paszek-Widzińska
Journal:  Rep Pract Oncol Radiother       Date:  2015-06-18

4.  Breathing-synchronized delivery: a potential four-dimensional tomotherapy treatment technique.

Authors:  Tiezhi Zhang; Weiguo Lu; Gustavo H Olivera; Harry Keller; Robert Jeraj; Rafael Manon; Minesh Mehta; Thomas R Mackie; Bhudatt Paliwal
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-06-14       Impact factor: 7.038

5.  Deformable registration of abdominal kilovoltage treatment planning CT and tomotherapy daily megavoltage CT for treatment adaptation.

Authors:  Deshan Yang; Summer R Chaudhari; S Murty Goddu; David Pratt; Divya Khullar; Joseph O Deasy; Issam El Naqa
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

6.  Megavoltage CT imaging quality improvement on TomoTherapy via tensor framelet.

Authors:  Hao Gao; X Sharon Qi; Yu Gao; Daniel A Low
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

7.  Erratum to: Molecular and cellular mechanisms that initiate pain and itch.

Authors:  Jialie Luo; Jing Feng; Shenbin Liu; Edgar T Walters; Hongzhen Hu
Journal:  Cell Mol Life Sci       Date:  2015-09       Impact factor: 9.261

8.  Comparative analysis of image guidance in two institutions for prostate cancer patients.

Authors:  Tomasz Piotrowski; Slav Yartsev; George Rodrigues; Tomasz Bajon
Journal:  Rep Pract Oncol Radiother       Date:  2014-01-02

9.  Improved oncologic outcomes with image-guided intensity-modulated radiation therapy using helical tomotherapy in locally advanced hepatocellular carcinoma.

Authors:  Hong In Yoon; Ik Jae Lee; Kwang-Hyub Han; Jinsil Seong
Journal:  J Cancer Res Clin Oncol       Date:  2014-05-09       Impact factor: 4.553

10.  A piecewise-focused high DQE detector for MV imaging.

Authors:  Josh Star-Lack; Daniel Shedlock; Dennis Swahn; Dave Humber; Adam Wang; Hayley Hirsh; George Zentai; Daren Sawkey; Isaac Kruger; Mingshan Sun; Eric Abel; Gary Virshup; Mihye Shin; Rebecca Fahrig
Journal:  Med Phys       Date:  2015-09       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.