Literature DB >> 26549992

Influence of the type of imaging on the delineation process during the treatment planning.

Weronika Jackowiak1, Bartosz Bąk2, Anna Kowalik3, Adam Ryczkowski3, Małgorzata Skórska3, Małgorzata Paszek-Widzińska2.   

Abstract

AIM: The aim of this study was to compare the intra- and interobserver contouring variability for structures with density of organ at risk in two types of tomography: kilovoltage computed tomography (KVCT) versus megavoltage computed tomography (MVCT). The intra- and interobserver differences were examined on both types of tomography for structures which simulate human tissue or organs.
MATERIALS AND METHODS: Six structures with density of the liver, bone, trachea, lung, soft tissue and muscle were created and used. For the measurements, the special water phantom with all structures was designed. To evaluate interobserver variability, five observers delineated the structures in both types of computed tomography (CT).
RESULTS: Intraobserver variability was in the range of 1-14% and was the largest for the liver. The observers segmented larger volumes on MVCT compared with KVCT for the trachea (79.56 ccm vs.74.91 ccm), lung (87.61 vs. 82.50), soft tissue (154.24 vs. 145.47) and muscle (164.01 vs. 157.89). For the liver (98.13 vs. 99.38) and bone (51.86 vs. 67.97), the volume on MVCT was smaller than KVCT. The statistically significant differences between observers were observed for structures with density of the liver, bone and soft tissue on KVCT and for the liver, lung and soft tissue on MVCT. For the structures with density of the trachea and muscles, there were no significant differences for both types of tomography.
CONCLUSIONS: During the contouring process the interobserver and intraobserver contouring uncertainty was larger on MVCT, especially for structures with HU near 80, compared with KVCT.

Entities:  

Keywords:  Delineation; Interobserver variability; Kilovoltage computed tomography; Megavoltage computed tomography

Year:  2015        PMID: 26549992      PMCID: PMC4597094          DOI: 10.1016/j.rpor.2015.05.004

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  27 in total

1.  Megavoltage CT image reconstruction during tomotherapy treatments.

Authors:  K J Ruchala; G H Olivera; J M Kapatoes; E A Schloesser; P J Reckwerdt; T R Mackie
Journal:  Phys Med Biol       Date:  2000-12       Impact factor: 3.609

Review 2.  Image guidance for precise conformal radiotherapy.

Authors:  Thomas Rockwell Mackie; Jeff Kapatoes; Ken Ruchala; Weiguo Lu; Chuan Wu; Gustavo Olivera; Lisa Forrest; Wolfgang Tome; Jim Welsh; Robert Jeraj; Paul Harari; Paul Reckwerdt; Bhudatt Paliwal; Mark Ritter; Harry Keller; Jack Fowler; Minesh Mehta
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

3.  Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unit.

Authors:  Sanford L Meeks; Joseph F Harmon; Katja M Langen; Twyla R Willoughby; Thomas H Wagner; Patrick A Kupelian
Journal:  Med Phys       Date:  2005-08       Impact factor: 4.071

4.  Planning target margin calculations for prostate radiotherapy based on intrafraction and interfraction motion using four localization methods.

Authors:  Chris Beltran; Michael G Herman; Brian J Davis
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-10-04       Impact factor: 7.038

5.  Impact of the spinal cord position uncertainty on the dose received during head and neck helical tomotherapy.

Authors:  Tomasz Piotrowski; Joanna Kaźmierska; Adam Sokołowski; Małgorzata Skórska; Agata Jodda; Adam Ryczkowski; Witold Cholewiński; Bartosz Bąk
Journal:  J Med Imaging Radiat Oncol       Date:  2013-04-01       Impact factor: 1.735

6.  Dual-energy (spectral) CT: applications in abdominal imaging.

Authors:  Alvin C Silva; Brian G Morse; Amy K Hara; Robert G Paden; Norio Hongo; William Pavlicek
Journal:  Radiographics       Date:  2011 Jul-Aug       Impact factor: 5.333

7.  Feasibility of CBCT-based target and normal structure delineation in prostate cancer radiotherapy: multi-observer and image multi-modality study.

Authors:  Carola Lütgendorf-Caucig; Irina Fotina; Markus Stock; Richard Pötter; Gregor Goldner; Dietmar Georg
Journal:  Radiother Oncol       Date:  2010-12-20       Impact factor: 6.280

8.  3D Variation in delineation of head and neck organs at risk.

Authors:  Charlotte L Brouwer; Roel J H M Steenbakkers; Edwin van den Heuvel; Joop C Duppen; Arash Navran; Henk P Bijl; Olga Chouvalova; Fred R Burlage; Harm Meertens; Johannes A Langendijk; Aart A van 't Veld
Journal:  Radiat Oncol       Date:  2012-03-13       Impact factor: 3.481

9.  Tomotherapy as a tool in image-guided radiation therapy (IGRT): theoretical and technological aspects.

Authors:  S Yartsev; T Kron; J Van Dyk
Journal:  Biomed Imaging Interv J       Date:  2007-01-01

10.  Evaluation of tomotherapy MVCT image enhancement program for tumor volume delineation.

Authors:  Spencer Martin; George Rodrigues; Quan Chen; Simon Pavamani; Nancy Read; Belal Ahmad; Alex Hammond; Varagur Venkatesan; James Renaud; Slav Yartsev
Journal:  J Appl Clin Med Phys       Date:  2011-04-12       Impact factor: 2.102

View more
  2 in total

1.  Influence of the contrast agents on treatment planning dose calculations of prostate and rectal cancers.

Authors:  Sahel Heydarheydari; Negin Farshchian; Abbas Haghparast
Journal:  Rep Pract Oncol Radiother       Date:  2016-05-06

2.  Autosegmentation of the rectum on megavoltage image guidance scans.

Authors:  L E A Shelley; M P F Sutcliffe; K Harrison; J E Scaife; M A Parker; M Romanchikova; S J Thomas; R Jena; N G Burnet
Journal:  Biomed Phys Eng Express       Date:  2019-01-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.