Does arthritis progress in the retained compartments after 'Oxford' medial unicompartmental arthroplasty? A clinical and radiological study with a minimum ten-year follow-up.

A E Weale1, D W Murray, R Crawford, V Psychoyios, A Bonomo, G Howell, J O'Connor, J W Goodfellow.   

Abstract

We determined the outcome of 56 'Oxford' unicompartmental replacements performed for anteromedial osteoarthritis of the knee between 1982 and 1987. Of these, 24 were in patients who had died without revision, one was lost to follow-up and two had been revised. Of the remaining 29 knees, 26 were examined clinically and radiologically, two were only examined clinically and one patient was contacted by telephone. The mean age of the patients was 80.3 years. At a mean follow-up of 11.4 years (10 to 14) the measurements of the knee score, range of movement and degree of deformity were not significantly different from those made one to two years after operation, except that the range of flexion had improved. Comparison of fluoroscopically-controlled radiographs at a similar interval of time showed no change in the appearance of the lateral compartments. The retained articular cartilage continued to function for ten or more years which suggests that anteromedial osteoarthritis may be considered as a focal disorder of the knee. This justifies continued efforts to develop methods of treatment which preserve intact joint structures.

Entities:  

Mesh:

Year:  1999        PMID: 10530837     DOI: 10.1302/0301-620x.81b5.9197

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  20 in total

1.  The impact of a high tibial valgus osteotomy and unicondylar medial arthroplasty on the treatment for knee osteoarthritis: a meta-analysis.

Authors:  Gunter Spahn; Gunther O Hofmann; Lars Victor von Engelhardt; Mengxia Li; Henning Neubauer; Hans Michael Klinger
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-11       Impact factor: 4.342

2.  [The bicompartmental knee joint prosthesis Journey Deuce: failure analysis and optimization strategies].

Authors:  M Müller; G Matziolis; R Falk; H Hommel
Journal:  Orthopade       Date:  2012-11       Impact factor: 1.087

3.  [Medial unicompartmental knee replacement using the "Oxford Uni" meniscal bearing knee].

Authors:  P R Aldinger; M Clarius; D W Murray; J W Goodfellow; S J Breusch
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

Review 4.  [Revision of unicompartmental knee arthroplasty].

Authors:  S Kirschner; J Lützner; S Fickert; K-P Günther
Journal:  Orthopade       Date:  2006-02       Impact factor: 1.087

5.  [Pre- and postoperative radioligical evaluation of knee joint endoprothesis. Orthopedist's view].

Authors:  F Mazoochian; C Glaser; A Fottner; S M Hauptmann; M Triantafyllou; C von Schulze Pellengahr; M F Reiser; V Jansson
Journal:  Radiologe       Date:  2006-09       Impact factor: 0.635

6.  Clinical and functional comparison of uni- and bicondylar sledge prostheses.

Authors:  S Fuchs; C O Tibesku; D Frisse; M Genkinger; H Laass; D Rosenbaum
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-12-24       Impact factor: 4.342

7.  MR imaging of the knee in patients with medial unicompartmental arthroplasty: comparison among sequences at 1.5 T.

Authors:  A Aliprandi; F Perona; M Bandirali; P Randelli; P Cabitza; F Sardanelli
Journal:  Radiol Med       Date:  2009-02-04       Impact factor: 3.469

8.  Pulsed lavage reduces the incidence of radiolucent lines under the tibial tray of Oxford unicompartmental knee arthroplasty: pulsed lavage versus syringe lavage.

Authors:  Michael Clarius; Christian Hauck; Joern B Seeger; Andrew James; David W Murray; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-02-14       Impact factor: 3.075

9.  Effect of arthritis in other compartment after unicompartmental arthroplasty.

Authors:  Ali Mofidi; Bo Lu; Johannes F Plate; Jason E Lang; Gary G Poehling; Riyaz H Jinnah
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-06-16

10.  Patient-perceived outcome measures following unicompartmental knee arthroplasty with mini-incision.

Authors:  I Jahromi; N P Walton; P J Dobson; P L Lewis; D G Campbell
Journal:  Int Orthop       Date:  2004-06-26       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.