The Dotter retriever and pigtail catheter: efficacy in extraction of chronic transvenous pacemaker leads.

R E Espinosa1, D L Hayes, R E Vlietstra, M J Osborn, M D McGoon.   

Abstract

Several techniques exist for percutaneous extraction of chronic pacemaker leads. To establish the efficacy of the Dotter retriever and pigtail catheter, we reviewed the removal of 59 endocardial pacemaker leads in 42 patients (mean age 71 years). The mean duration of lead implantation was 44 months (range 1-169 months). Thirty-two leads were withdrawn with simple traction alone, and five leads were abandoned when traction failed. The remaining 22 leads were manipulated with a Dotter retriever or pigtail catheter, or both. Twelve leads were dislodged from the endocardium with simple traction (10) or with traction transmitted through an entwining pigtail catheter (2), but they could not be fully withdrawn. Eleven of these leads (92%) were then successfully extracted with the Dotter retriever. Seven of the remaining 10 leads were successfully dislodged and removed by the Dotter retriever. Overall, 9 of 12 leads (75%) that could not be dislodged from the endocardium with simple traction were removed with a Dotter retriever or pigtail catheter, or both. Three patients in whom no catheter method worked required thoracotomy for removal of infected leads. No complications resulted from use of the Dotter retriever or pigtail catheter. We conclude that the Dotter retriever and pigtail catheter have moderate efficacy for dislodging chronic endocardial leads. Once mobilized, however, the leads can be withdrawn with great success with the Dotter retriever. Newer technology should not result in the abandonment of this proven technique.

Entities:  

Mesh:

Year:  1993        PMID: 7508618     DOI: 10.1111/j.1540-8159.1993.tb02347.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  4 in total

1.  Percutaneous extraction of transvenous defibrillator leads using the VascoExtor pacing lead removal system.

Authors:  V P Vassilikos; T N Maounis; J Chiladakis; D V Cokkinos; A S Manolis
Journal:  J Interv Card Electrophysiol       Date:  1999-10       Impact factor: 1.900

2.  Extraction of permanent pacing leads: there are still controversies.

Authors:  D L Hayes
Journal:  Heart       Date:  1996-06       Impact factor: 5.994

Review 3.  Endovascular extraction techniques for pacemaker and ICD lead extraction: Part 1.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2001-04       Impact factor: 2.380

4.  Percutaneous extraction of transvenous permanent pacemaker/defibrillator leads.

Authors:  Stylianos Paraskevaidis; Dimitrios Konstantinou; Vassilios Vassilikos; Efstratios Theofilogiannakos; Lilian Mantziari; Athanasia Megarisiotou; Ioannis Galitsianos; Charalambos Karvounis
Journal:  Biomed Res Int       Date:  2014-05-26       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.