Literature DB >> 29076815

Transvenous lead extraction: Can it be simple yet safe?

Antonios P Antoniadis, Vassilios P Vassilikos1.   

Abstract

Entities:  

Mesh:

Year:  2017        PMID: 29076815      PMCID: PMC5731526          DOI: 10.14744/AnatolJCardiol.2017.25858

Source DB:  PubMed          Journal:  Anatol J Cardiol        ISSN: 2149-2263            Impact factor:   1.596


× No keyword cloud information.
The clinical need for lead extraction procedures has increased in recent years. Increasing device implant rates are related to a subsequent need for repeated generator replacements, lead revisions, and system upgrades. These, in turn, have collectively led to a respective rise in the rates of systemic infections and other lead-related problems which may mandate lead extraction. Traditionally, lead extraction procedures encompass clinical challenges and risks which dictate careful pre-procedure planning within a multi-disciplinary team (1). Factors thought to preclude a straightforward extraction procedure are a prolonged length of time since the initial lead implantation, the presence of defibrillator leads, female gender, old age, left ventricular dysfunction, systemic infection, a poor overall clinical status of the patient, and significant co-morbidities (2). Fibrous adhesions preferentially develop in the venous insertion site, the subclavian vein, the superior vena cava and the tip-endocardial interface (3, 4). These areas are particularly prone to damage during an extraction procedure, which can then lead to catastrophic complications, even in the hands of the most experienced operators. Extraction procedures are performed in the cardiac electrophysiology/catheterization laboratory, in the operating theatre, or in a hybrid laboratory. Under all circumstances, it is imperative that onsite cardiothoracic surgical backup and anesthetic cover is available. The Heart Rhythm Society consensus statement on lead extraction procedures highlights the importance of establishing a robust clinical indication for lead extraction prior to the procedure. A confirmation that the clinical risk deriving from leaving the existing leads in situ is indeed higher than the risk of the extraction procedure per se, is essential to justify the rationale for proceeding to an extraction procedure (5). The majority of lead extractions are performed via the transvenous approach, although open chest extraction may be required in specific cases (6). Tools and techniques utilized for lead extractions typically range from simple traction with regular stylets to locking stylets (7), telescoping sheaths, and more advanced technologies, such as powered mechanical sheaths, namely operating with radiofrequency, manual rotational force, or laser energy. The latter, sophisticated methods, laser extraction in particular, are associated with higher procedural success, greater time-efficiency, and an equal safety profile (8, 9). One should not disregard, however, the financial constraints which may inhibit a more widespread use of powered mechanical sheaths for lead extraction procedures. In the modern era of increased cost-awareness, the routine use of cutting-edge, yet costly modalities may be prohibitive, especially in certain countries with limited resources. In this context, the need for clinically efficient, cost-effective means of lead extraction that do not compromise patient safety is particularly timely and relevant. In this issue of the Anatolian Journal of Cardiology, an article entitled “Cardiac implantable electronic device lead extraction with use of the lead-locking device (LLD) system: keeping it simple, safe and inexpensive with mechanical tools and local anaesthesia,” Manolis et al. (10) report a single-center experience on the use of an LLD for lead extraction procedures. Over a 10-year period, the use of LLDs was required in 92 of 98 leads and yielded a procedural success of 98%, while it was supplemented with the use of telescopic sheaths in 28% of patients. No major complications were recorded. The results of this study are encouraging, but have to be interpreted in the appropriate context. Clearly, patient safety is the first clinical priority, and should overcome any financial aspects relating to procedural costs. On the other hand, the availability of adequate resources and staff training to employ more advanced technologies may simply not exist in some countries, and a referral to a foreign center may not be straightforward. It is important to recognize that an extraction procedure may be feasible with the use of more conventional tools which mitigate not only clinical risks but also costs. However, it is equally critical to be able to identify the subset of patients at high-risk for procedural complications during a lead extraction procedure, who will benefit from being referred to a high-volume center where the most contemporary facilities are available. Therefore, the development of clinical scores to enable an accurate risk-stratification of a patient requiring a lead extraction procedure is of utmost importance. The Lead Extraction Difficulty (LED) score was developed for this purpose and is defined as: number of extracted leads within a procedure + lead age (years from implant) + 1 if dual-coil – 1 if vegetation. An LED score greater than 10 could predict a complex procedure (i.e., with increased fluoroscopy time) with a sensitivity of 78.3% and a specificity of 76.7 % (11). More recently, a new risk score model named IKAR (I=infective indications, K=kidney dysfunction, A=age ≥56, R=removal of high voltage lead) was published. Patients with IKAR score ≥3 points exhibited 79% mortality, as compared with 16% in patients with a score of 1–2 (12). Lead extraction procedures are possible nowadays with a discernible but limited number of risks. Notwithstanding the considerable progress achieved, lead extraction still remains a high-risk procedure, and should only be performed in appropriate centers. A uniform classification scheme of outcomes and quality measures is essential for the meaningful evaluation of results reported in different studies. Prospective multicenter registries are reasonably expected to provide additional insights with regard to standard management strategies as well as short- and long-term outcomes (13).
  11 in total

1.  Percutaneous extraction of transvenous defibrillator leads using the VascoExtor pacing lead removal system.

Authors:  V P Vassilikos; T N Maounis; J Chiladakis; D V Cokkinos; A S Manolis
Journal:  J Interv Card Electrophysiol       Date:  1999-10       Impact factor: 1.900

2.  Clinical study of the laser sheath for lead extraction: the total experience in the United States.

Authors:  Charles L Byrd; Bruce L Wilkoff; Charles J Love; T Duncan Sellers; Christopher Reiser
Journal:  Pacing Clin Electrophysiol       Date:  2002-05       Impact factor: 1.976

3.  Predicting the difficulty of a lead extraction procedure: the LED index.

Authors:  Luca Bontempi; Francesca Vassanelli; Manuel Cerini; Antonio D'Aloia; Enrico Vizzardi; Alessio Gargaro; Francesco Chiusso; Rashad Mamedouv; Alessandro Lipari; Antonio Curnis
Journal:  J Cardiovasc Med (Hagerstown)       Date:  2014-08       Impact factor: 2.160

4.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

Authors:  Bruce L Wilkoff; Charles J Love; Charles L Byrd; Maria Grazia Bongiorni; Roger G Carrillo; George H Crossley; Laurence M Epstein; Richard A Friedman; Charles E H Kennergren; Przemyslaw Mitkowski; Raymond H M Schaerf; Oussama M Wazni
Journal:  Heart Rhythm       Date:  2009-05-22       Impact factor: 6.343

Review 5.  Extraction of transvenous pacing and ICD leads.

Authors:  Macy C Smith; Charles J Love
Journal:  Pacing Clin Electrophysiol       Date:  2008-06       Impact factor: 1.976

6.  Cardiac implantable electronic device lead extraction in patients with underlying infection using open thoracotomy or percutaneous techniques.

Authors:  Divyang Patel; Faris Khan; Hemal Shah; Sanjoy Bhattacharya; Evan Adelstein; Samir Saba
Journal:  Cardiol J       Date:  2014-05-20       Impact factor: 2.737

7.  Five-years experience with intravascular lead extraction. U.S. Lead Extraction Database.

Authors:  H J Smith; N E Fearnot; C L Byrd; B L Wilkoff; C J Love; T D Sellers
Journal:  Pacing Clin Electrophysiol       Date:  1994-11       Impact factor: 1.976

8.  Risk score to assess mortality risk in patients undergoing transvenous lead extraction.

Authors:  Ewa Oszczygieł; Andrzej Kutarski; Andrzej Oszczygieł; Beata Mańkowska-Załuska; Michał Chudzik; Jerzy Krzysztof Wranicz; Iwona Cygankiewicz
Journal:  Pacing Clin Electrophysiol       Date:  2017-07-21       Impact factor: 1.976

9.  ELECTRa (European Lead Extraction ConTRolled) Registry--shedding light on transvenous lead extraction real-world practice in Europe.

Authors:  Maria Grazia Bongiorni; Simone L Romano; Charles Kennergren; Christian Butter; Jean Claude Deharo; Andrzej Kutarsky; Christopher Aldo Rinaldi; Aldo P Maggioni; Carina Blomström-Lundqvist; Angelo Auricchio
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2013-08-14

10.  Cardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia.

Authors:  Antonis S Manolis; Georgios Georgiopoulos; Sofia Metaxa; Spyridon Koulouris; Dimitris Tsiachris
Journal:  Anatol J Cardiol       Date:  2017-08-11       Impact factor: 1.596

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.