Literature DB >> 10464807

Radiation safety considerations for diagnostic radiology personnel.

L Brateman1.   

Abstract

In radiation protection, the guiding philosophy is ALARA (as low as reasonably achievable), and states have regulatory authority. Dose limits are in part based on effective dose equivalent and differences in tissue sensitivities. In diagnostic radiology, the main source of occupational dose is scattered radiation from the patient--particularly from fluoroscopically guided procedures. Personnel stand near patients for long times, and angulated geometries with C-arm equipment may result in high personnel doses from backscatter. For all procedures, judicious applications of time, distance, and shielding affect dose. Appropriate use includes collimating properly, optimizing beam-on time, minimizing distances between image intensifier and patient, ensuring sufficient distance between patient and x-ray tube, and optimizing exposure rates for image quality and dose. Although dose limits typically regulate maximum whole-body dose, protective clothing worn by fluoroscopists reduces personnel risks; weighting factors can be applied to estimate effective dose equivalent. Pregnant personnel have lower limits, which apply only with voluntary declaration of pregnancy. With appropriate precautions, fetal doses can typically remain within recommended limits without changes in occupational tasks. Radiation workers in each state must ensure that regulations are appropriate. Then, for protection of both employee and employers, the rules can and must be followed.

Entities:  

Mesh:

Year:  1999        PMID: 10464807     DOI: 10.1148/radiographics.19.4.g99jl231037

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  11 in total

1.  Radiation organ doses received in a nationwide cohort of U.S. radiologic technologists: methods and findings.

Authors:  Steven L Simon; Dale L Preston; Martha S Linet; Jeremy S Miller; Alice J Sigurdson; Bruce H Alexander; Deukwoo Kwon; R Craig Yoder; Parveen Bhatti; Mark P Little; Preetha Rajaraman; Dunstana Melo; Vladimir Drozdovitch; Robert M Weinstock; Michele M Doody
Journal:  Radiat Res       Date:  2014-10-31       Impact factor: 2.841

2.  The principle of digital subtraction angiography and radiological protection.

Authors:  K Okamoto; J Ito; K Sakai; S Yoshimura
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

3.  Occupational radiation exposure from C arm fluoroscopy during common orthopaedic surgical procedures and its prevention.

Authors:  Anupam Mahajan; Sumant Samuel; Atul K Saran; M K Mahajan; M K Mam
Journal:  J Clin Diagn Res       Date:  2015-03-01

4.  Radiation-reducing planning of cardiac catheterisation.

Authors:  E Kuon; J B Dahm; D M Robinson; K Empen; M Günther; W Wucherer
Journal:  Z Kardiol       Date:  2005-10

Review 5.  Established and emerging dose reduction methods in cardiac computed tomography.

Authors:  Gary R Small; Mustapha Kazmi; Robert A Dekemp; Benjamin J W Chow
Journal:  J Nucl Cardiol       Date:  2011-08       Impact factor: 5.952

6.  ALARA, image gently and CT-induced cancer.

Authors:  Mervyn D Cohen
Journal:  Pediatr Radiol       Date:  2015-02-14

7.  Relationships Between Radiation Exposure Dose, Time, and Projection in Videofluoroscopic Swallowing Studies.

Authors:  Heather Shaw Bonilha; Janina Wilmskoetter; Sameer Tipnis; Janet Horn; Bonnie Martin-Harris; Walter Huda
Journal:  Am J Speech Lang Pathol       Date:  2019-05-21       Impact factor: 2.408

8.  Suprapatellar intramedullary nailing of tibial shaft fractures in pregnancy. A report of two cases.

Authors:  Attilio Basile; Laura Palmieri; Riccardo Lanzetti; Pasquale Sessa; Marco Spoliti; Alessio Giai Via; Gennaro Pipino
Journal:  BMC Pregnancy Childbirth       Date:  2022-06-28       Impact factor: 3.105

9.  Comparison of radiation exposure to physicians between anteroposterior and lateral real-time fluoroscopy when performing lumbar transforaminal epidural steroid injections: A randomized controlled trial.

Authors:  Seung Hee Yoo; Won-Joong Kim; Mi Jin Jue; Min Jin Lee
Journal:  Medicine (Baltimore)       Date:  2022-07-08       Impact factor: 1.817

10.  Implementation of a competency check-off in diagnostic fluoroscopy for radiology trainees: impact on reducing radiation for three common fluoroscopic exams in children.

Authors:  Sweta Shah; Stephane L Desouches; Lisa H Lowe; Nima Kasraie; Brenton Reading
Journal:  Pediatr Radiol       Date:  2014-07-24
View more