Literature DB >> 28261847

Improved field-mapping and artifact correction in multispectral imaging.

Brady Quist1,2, Xinwei Shi1,2, Hans Weber1, Brian A Hargreaves1,2.   

Abstract

PURPOSE: To develop a method for improved B0 field-map estimation, deblurring, and image combination for multispectral imaging near metal.
METHODS: A goodness-of-fit field-map estimation technique is proposed that uses only the multispectral imaging (MSI) data to estimate the field map. Using the improved field map, a novel deblurring technique is proposed that also employs a new image combination scheme to reduce the effects of noise and other residual MSI artifacts. The proposed field-map estimation and deblurring techniques are compared to the current methods in phantoms and/or in vivo from subjects with knee, hip, and spinal metallic implants.
RESULTS: Phantom experiments validate that the goodness-of-fit field-map estimation is less sensitive to noise and bias than the conventional center-of-mass technique, which reduces distortion in the deblurring methods. The new deblurring approach also is substantially less sensitive to noise and distortion than the current deblurring method, as demonstrated in phantoms and in vivo, and is able to find a good tradeoff between deblurring and distortion.
CONCLUSION: The proposed methods not only enable field-mapping with reduced noise sensitivity but are able to create deblurred images with less distortion and better signal-to-noise ratio with no additional scan time, thereby enabling improved visualization of underlying anatomy near metallic implants. Magn Reson Med 78:2022-2034, 2017.
© 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  MRI of arthroplasty; field-mapping; image artifacts; metal implants

Mesh:

Substances:

Year:  2017        PMID: 28261847      PMCID: PMC5796784          DOI: 10.1002/mrm.26597

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  19 in total

1.  Complications of total hip arthroplasty: MR imaging-initial experience.

Authors:  L M White; J K Kim; M Mehta; N Merchant; M E Schweitzer; W B Morrison; C R Hutchison; A E Gross
Journal:  Radiology       Date:  2000-04       Impact factor: 11.105

2.  Imaging near metal with a MAVRIC-SEMAC hybrid.

Authors:  K M Koch; A C Brau; W Chen; G E Gold; B A Hargreaves; M Koff; G C McKinnon; H G Potter; K F King
Journal:  Magn Reson Med       Date:  2011-01       Impact factor: 4.668

3.  MRI of hip prostheses using single-point methods: in vitro studies towards the artifact-free imaging of individuals with metal implants.

Authors:  P Ramos-Cabrer; J P M van Duynhoven; A Van der Toorn; K Nicolay
Journal:  Magn Reson Imaging       Date:  2004-10       Impact factor: 2.546

4.  Correction of MR image distortions induced by metallic objects using a 3D cubic B-spline basis set: application to stereotactic surgical planning.

Authors:  S Skare; J L R Andersson
Journal:  Magn Reson Med       Date:  2005-07       Impact factor: 4.668

5.  New MR imaging methods for metallic implants in the knee: artifact correction and clinical impact.

Authors:  Christina A Chen; Weitian Chen; Stuart B Goodman; Brian A Hargreaves; Kevin M Koch; Wenmaio Lu; Anja C Brau; Christine E Draper; Scott L Delp; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2011-05       Impact factor: 4.813

6.  Characterizing the limits of MRI near metallic prostheses.

Authors:  Matthew R Smith; Nathan S Artz; Curtis Wiens; Diego Hernando; Scott B Reeder
Journal:  Magn Reson Med       Date:  2014-12-05       Impact factor: 4.668

7.  Magnetic resonance imaging after total hip arthroplasty: evaluation of periprosthetic soft tissue.

Authors:  Hollis G Potter; Bryan J Nestor; Carolyn M Sofka; Stephanie T Ho; Lance E Peters; Eduardo A Salvati
Journal:  J Bone Joint Surg Am       Date:  2004-09       Impact factor: 5.284

8.  MRI of early symptomatic metal-on-metal total hip arthroplasty: a retrospective review of radiological findings in 20 hips.

Authors:  A P Toms; T J Marshall; J Cahir; C Darrah; J Nolan; S T Donell; T Barker; J K Tucker
Journal:  Clin Radiol       Date:  2007-10-24       Impact factor: 2.350

9.  SEMAC: Slice Encoding for Metal Artifact Correction in MRI.

Authors:  Wenmiao Lu; Kim Butts Pauly; Garry E Gold; John M Pauly; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

10.  Metallic implant geometry and susceptibility estimation using multispectral B0 field maps.

Authors:  Xinwei Shi; Daehyun Yoon; Kevin M Koch; Brian A Hargreaves
Journal:  Magn Reson Med       Date:  2016-07-06       Impact factor: 4.668

View more
  2 in total

1.  Dipole modeling of multispectral signal for detecting metallic biopsy markers during MRI-guided breast biopsy: a pilot study.

Authors:  Sarah Eskreis-Winkler; Katherine Simon; Melissa Reichman; Pascal Spincemaille; Thanh Nguyen; Youngwook Kee; Junghun Cho; Paul J Christos; Michele Drotman; Martin R Prince; Elizabeth A Morris; Yi Wang
Journal:  Magn Reson Med       Date:  2019-10-21       Impact factor: 4.668

2.  Multispectral Imaging for Metallic Biopsy Marker Detection During MRI-Guided Breast Biopsy: A Feasibility Study for Clinical Translation.

Authors:  Sarah Eskreis-Winkler; Katherine Simon; Melissa Reichman; Pascal Spincemaille; Thanh D Nguyen; Paul J Christos; Michele Drotman; Martin R Prince; Katja Pinker; Elizabeth J Sutton; Elizabeth A Morris; Yi Wang
Journal:  Front Oncol       Date:  2021-03-22       Impact factor: 6.244

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.