Theoretical considerations of monitor unit calculations for intensity modulated beam treatment planning.

A Boyer1, L Xing, C M Ma, B Curran, R Hill, A Kania, A Bleier.   

Abstract

A treatment planning system to compute intensity modulated radiotherapy (IMRT) treatments using inverse planning was investigated. The system was designed to optimize the intensity patterns required to treat a specified target volume with specified normal structure constraints. A beam model that uses the convolution of pencil beams was used to compute the dose distributions. A multileaf collimator leaf-setting sequence intended to produce the intensity pattern was computed along with the monitor units required to deliver each of a number of fixed-gantry modulated fields. Computer calculations are commonly verified using an independent manual procedure. It is difficult to calculate treatment delivery monitor units for this variant of IMRT using manual methods. Since manual calculations are not feasible, it is important both to understand and to verify the calculation of treatment monitor units by the planning system algorithm. A formal analysis was made of the dose calculation model and the monitor unit calculation embedded in the algorithm. Experimental verification of the dose delivered by plans computed with the methodology demonstrated an agreement of better than 4% between the dose model and measurements.

Mesh:

Substances:

Year:  1999        PMID: 10076972     DOI: 10.1118/1.598502

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Independent calculation of monitor units for VMAT and SPORT.

Authors:  Xin Chen; Karl Bush; Aiping Ding; Lei Xing
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

2.  Monitor unit calculations for external photon and electron beams: Report of the AAPM Therapy Physics Committee Task Group No. 71.

Authors:  John P Gibbons; John A Antolak; David S Followill; M Saiful Huq; Eric E Klein; Kwok L Lam; Jatinder R Palta; Donald M Roback; Mark Reid; Faiz M Khan
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

3.  Optimized point dose measurement for monitor unit verification in intensity modulated radiation therapy using 6 MV photons by three different methodologies with different detector-phantom combinations: A comparative study.

Authors:  Biplab Sarkar; Bhaswar Ghosh; Sukumaran Mahendramohan; Ayan Basu; Jyotirup Goswami; Amitabh Ray
Journal:  J Med Phys       Date:  2010-07

4.  Quasi-independent monitor unit calculation for intensity modulated sequential tomotherapy.

Authors:  Jen-San Tsai; Mark J Engler; James Liu
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

5.  Dosimetric verification of inverse planned step and shoot multileaf collimator fields from a commercial treatment planning system.

Authors:  M A MacKenzie; M Lachaine; B Murray; B G Fallone; D Robinson; G C Field
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

6.  Dosimetric validation and clinical implementation of two 3D dose verification systems for quality assurance in volumetric-modulated arc therapy techniques.

Authors:  Francisco Clemente-Gutiérrez; Consuelo Pérez-Vara
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

7.  Independent calculation of dose from a helical TomoTherapy unit.

Authors:  John P Gibbons; Koren Smith; Dennis Cheek; Isaac Rosen
Journal:  J Appl Clin Med Phys       Date:  2009-02-05       Impact factor: 2.102

8.  Shielding evaluation for IMRT implementation in an existing accelerator vault.

Authors:  R A Price; O Chibani; C-M Ma
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.