Pulse oximetry: principles and limitations.

J E Sinex1.   

Abstract

The pulse oximeter has become an essential tool in the modern practice of emergency medicine. However, despite the reliance placed on the information this monitor offers, the underlying principles and associated limitations of pulse oximetry are poorly understood by medical practitioners. This article reviews the principles of pulse oximetry, with an eye toward recognizing the limitations of this tool. Among these are performance limitations in the settings of carboxyhemoglobinemia, methemoglobinemia, motion artifact, hypotension, vasoconstriction, and anemia. The accuracy of pulse oximetry is discussed in light of these factors, with further discussion of applications for pulse oximetry in emergency medicine, including both oximetric and plethysmographic operation. The pulse oximeter is an invaluable instrument for emergency medicine practice, but as with any test the data it offers must be critically appraised for proper interpretation and utilization.

Entities:  

Mesh:

Year:  1999        PMID: 9928703     DOI: 10.1016/s0735-6757(99)90019-0

Source DB:  PubMed          Journal:  Am J Emerg Med        ISSN: 0735-6757            Impact factor:   2.469


  68 in total

1.  Acute cardiogenic pulmonary oedema with multiorgan dysfunction--still to learn more about nitrobenzene poisoning.

Authors:  Avinash Agrawal; Manish Gutch; Rahul Arora; Nirdesh Jain
Journal:  BMJ Case Rep       Date:  2011-12-20

2.  The sounds of saturation.

Authors:  David C Santamore; Thomas G Cleaver
Journal:  J Clin Monit Comput       Date:  2004-04       Impact factor: 2.502

3.  First reported case of hemoglobin lansing in Asia detected by false low oxygen saturation on pulse oximetry.

Authors:  Kenji Ishitsuka; Junji Uchino; Junko Kato; Mikihiro Ikuta; Kentaro Watanabe; Akira Matsunaga; Kazuo Tamura
Journal:  Int J Hematol       Date:  2012-05-26       Impact factor: 2.490

4.  The use (or otherwise) of pulse in general practice.

Authors:  Georgia Ingram; Neil Munro
Journal:  Br J Gen Pract       Date:  2005-07       Impact factor: 5.386

5.  Investigation of photoplethysmographic signals and blood oxygen saturation values on healthy volunteers during cuff-induced hypoperfusion using a multimode PPG/SpO₂ sensor.

Authors:  M Shafique; P A Kyriacou; S K Pal
Journal:  Med Biol Eng Comput       Date:  2012-05-04       Impact factor: 2.602

6.  Evaluation of a pulse oximeter sensor tester.

Authors:  Shuba Dugani; Iljaz Hodzovic; Seema Sindhakar; Aida Nadra; Clare Dunstan; Anthony Richard Wilkes; John Mecklenburgh
Journal:  J Clin Monit Comput       Date:  2011-05-18       Impact factor: 2.502

7.  Rebuttal to the con statement.

Authors:  Buddha Basnyat
Journal:  High Alt Med Biol       Date:  2014-12       Impact factor: 1.981

8.  Quantitative real-time pulse oximetry with ultrafast frequency-domain diffuse optics and deep neural network processing.

Authors:  Yanyu Zhao; Mattew B Applegate; Raeef Istfan; Ashvin Pande; Darren Roblyer
Journal:  Biomed Opt Express       Date:  2018-11-05       Impact factor: 3.732

9.  Pulse Oximetry Is Insensitive for Detection of Hepatopulmonary Syndrome in Patients Evaluated for Liver Transplantation.

Authors:  Kimberly A Forde; Michael B Fallon; Michael J Krowka; Michael Sprys; David S Goldberg; Karen L Krok; Mamta Patel; Grace Lin; Jae K Oh; Carl D Mottram; Paul D Scanlon; Steven M Kawut
Journal:  Hepatology       Date:  2018-12-18       Impact factor: 17.425

10.  Detection of pulsus paradoxus by pulse oximetry in pediatric patients after cardiac surgery.

Authors:  Hamid Amoozgar; Hossein Ghodsi; Mohammad Borzoee; Ahmad Ali Amirghofran; Gholamhossein Ajami; Zahra Serati
Journal:  Pediatr Cardiol       Date:  2008-07-30       Impact factor: 1.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.