Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy.

L Cozzi1, A Fogliata, F Buffa, S Bieri.   

Abstract

The Hounsfield units into density conversion for a commercial treatment planning system (TPS) is discussed. The impact of an average calibration table provided by the manufacturer on computed doses was investigated when a customer calibration could not be included in the TPS. The maximum error determined on the computed monitor units per Gy was found to be about 2%, being below 1% on average. The relative importance of the parameters used for CT image acquisition is also discussed. The applied voltage was the most relevant parameter leading to errors in the reconstructed Hounsfield numbers of about 300 units for high densities.

Mesh:

Year:  1998        PMID: 9925254     DOI: 10.1016/s0167-8140(98)00072-3

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  20 in total

1.  Computed tomography as a source of electron density information for radiation treatment planning.

Authors:  Witold Skrzyński; Sylwia Zielińska-Dabrowska; Marta Wachowicz; Wioletta Slusarczyk-Kacprzyk; Paweł F Kukołowicz; Wojciech Bulski
Journal:  Strahlenther Onkol       Date:  2010-05-17       Impact factor: 3.621

2.  Hounsfield units variations: impact on CT-density based conversion tables and their effects on dose distribution.

Authors:  B Zurl; R Tiefling; P Winkler; P Kindl; K S Kapp
Journal:  Strahlenther Onkol       Date:  2013-11-09       Impact factor: 3.621

3.  Can CT scan protocols used for radiotherapy treatment planning be adjusted to optimize image quality and patient dose? A systematic review.

Authors:  Anne T Davis; Antony L Palmer; Andrew Nisbet
Journal:  Br J Radiol       Date:  2017-05-23       Impact factor: 3.039

Review 4.  Emerging role of MRI in radiation therapy.

Authors:  Hersh Chandarana; Hesheng Wang; R H N Tijssen; Indra J Das
Journal:  J Magn Reson Imaging       Date:  2018-09-08       Impact factor: 4.813

5.  Current state of the art brachytherapy treatment planning dosimetry algorithms.

Authors:  P Papagiannis; E Pantelis; P Karaiskos
Journal:  Br J Radiol       Date:  2014-07-16       Impact factor: 3.039

6.  Acoustic and ultrasonographic characterization of polychloroprene, beeswax, and carbomer-gel to mimic soft-tissue for diagnostic ultrasound.

Authors:  Debjani Phani; Rajasekhar Konduru Varadarajulu; Anjali Thomas; Raghukumar Paramu; M Suheshkumar Singh; V S Shaiju; Venugopal Muraleedharan; Raghuram Kesavan Nair
Journal:  Phys Eng Sci Med       Date:  2020-08-18

7.  Quantitative assessment of irradiated lung volume and lung mass in breast cancer patients treated with tangential fields in combination with deep inspiration breath hold (DIBH).

Authors:  Brigitte Zurl; Heidi Stranzl; Peter Winkler; Karin Sigrid Kapp
Journal:  Strahlenther Onkol       Date:  2010-02-22       Impact factor: 3.621

8.  Physical density estimations of single- and dual-energy CT using material-based forward projection algorithm: a simulation study.

Authors:  Kai-Wen Li; Daiyu Fujiwara; Akihiro Haga; Huisheng Liu; Li-Sheng Geng
Journal:  Br J Radiol       Date:  2021-09-29       Impact factor: 3.039

9.  Radiotherapy dose calculation on KV cone-beam CT image for lung tumor using the CIRS calibration.

Authors:  Changsheng Ma; Jianping Cao; Yong Yin; Jian Zhu
Journal:  Thorac Cancer       Date:  2014-01-02       Impact factor: 3.500

Review 10.  Computed tomography imaging parameters for inhomogeneity correction in radiation treatment planning.

Authors:  Indra J Das; Chee-Wai Cheng; Minsong Cao; Peter A S Johnstone
Journal:  J Med Phys       Date:  2016 Jan-Mar
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.