Literature DB >> 9878969

Clinical methods for evaluating implant framework fit.

J Y Kan1, K Rungcharassaeng, K Bohsali, C J Goodacre, B R Lang.   

Abstract

STATEMENT OF PROBLEM: Passive fit of implant-supported-prosthesis frameworks has been suggested as a prerequisite for successful long-term osseointegration. However, there are no scientific guidelines as to what is passive fit and how to achieve and measure it.
PURPOSE: The purpose of this article is to discuss passive fit and to review the various clinical methods that have been suggested for evaluating implant framework fit.Methods. The dental literature was reviewed to identify the clinical methods that have been used to evaluate implant framework fit.
CONCLUSIONS: The suggested levels of passive fit are empirical. Numerous techniques have been advocated to evaluate the prosthesis-implant interface, but none individually provides objective results. It is suggested that clinicians use a combination of the available methods to minimize misfits.

Mesh:

Substances:

Year:  1999        PMID: 9878969     DOI: 10.1016/s0022-3913(99)70229-5

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  40 in total

1.  Evaluation of impression accuracy for a four-implant mandibular model--a digital approach.

Authors:  Michael Stimmelmayr; Kurt Erdelt; Jan-Frederik Güth; Arndt Happe; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-10-19       Impact factor: 3.573

2.  Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Daniel Edelhoff; Florian Beuer
Journal:  Clin Oral Investig       Date:  2011-06-04       Impact factor: 3.573

Review 3.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

4.  Accuracy of multi-unit implant impression: traditional techniques versus a digital procedure.

Authors:  Maria Menini; Paolo Setti; Francesco Pera; Paolo Pera; Paolo Pesce
Journal:  Clin Oral Investig       Date:  2017-09-30       Impact factor: 3.573

5.  Survival and success rates of soft-milled cobalt-chromium-ceramic full-arch screw-retained implant-supported prostheses: a 2- to 7-year follow-up retrospective study.

Authors:  S Levartovsky; A Arieli; N Fridenberg; S Matalon; R Pilo
Journal:  Clin Oral Investig       Date:  2021-02-22       Impact factor: 3.573

6.  Clinical study evaluating the discrepancy of two different impression techniques of four implants in an edentulous jaw.

Authors:  Michael Stimmelmayr; Jan-Frederik Güth; Kurt Erdelt; Arndt Happe; Markus Schlee; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-12-06       Impact factor: 3.573

7.  Influence of prosthetic screw material on joint stability in passive and non-passive implant-supported dentures.

Authors:  Aloísio Oro Spazzin; Guilherme Elias Pessanha Henriques; Mauro Antônio de Arruda Nóbilo; Rafael Leonardo Xediek Consani; Lourenço Correr-Sobrinho; Marcelo Ferraz Mesquita
Journal:  Open Dent J       Date:  2009-12-30

8.  Implants and all-ceramic restorations in a patient treated for aggressive periodontitis: a case report.

Authors:  Jin-Sun Hong; In-Sung Yeo; Sung-Hun Kim; Jai-Bong Lee; Jung-Suk Han; Jae-Ho Yang
Journal:  J Adv Prosthodont       Date:  2010-09-30       Impact factor: 1.904

9.  Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

Authors:  Ye-Kyu Rhee; Yoon-Hyuk Huh; Lee-Ra Cho; Chan-Jin Park
Journal:  J Adv Prosthodont       Date:  2015-12-30       Impact factor: 1.904

10.  Assessing fit at the implant-abutment junction with a radiographic device that does not require access to the implant body.

Authors:  Kevin C Lin; Chandur P K Wadhwani; Jing Cheng; Arun Sharma; Frederick Finzen
Journal:  J Prosthet Dent       Date:  2014-05-14       Impact factor: 3.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.