Assessing fit at the implant-abutment junction with a radiographic device that does not require access to the implant body.

Kevin C Lin1, Chandur P K Wadhwani2, Jing Cheng3, Arun Sharma4, Frederick Finzen5.   

Abstract

STATEMENT OF PROBLEM: Radiograph paralleling devices provide an excellent means of obtaining orthogonal radiographs for the evaluation of the fit of implant restorations. Unfortunately, the clinical applicability of such devices is a significant issue because access to the implant body must be obtained at each radiographic appointment.
PURPOSE: The purpose of the study was to investigate whether the fit or microgap at the implant-abutment junction could be more accurately and confidently assessed with a novel radiograph paralleling device that did not require access to the implant body once a proper registration index was made.
MATERIAL AND METHODS: Microgaps of 0, 50, and 100 μm were introduced at the implant-abutment junction of a provisional implant crown in a manikin-typodont assembly. Dental assistants made 54 radiographs (18 per microgap) of the crown with and without a radiograph paralleling device; 9 clinicians then evaluated the standardized radiographs for the presence of misfit. The Cochran-Mantel-Haenszel test and the corresponding odds ratios were used to evaluate the effectiveness of the paralleling device in helping clinicians better assess misfit from the radiographs made.
RESULTS: The use of the device led to a higher percentage of accuracy under all conditions (79.0% vs 70.4% at the 0-μm gap, 77.8% vs 16.1% at the 50-μm gap, and 100% vs 92.6% at the 100-μm gap); the improvement was statistically significant at the 50-μm gap (P<.001) and 100-μm gap (P=.049) but not at the 0-μm gap (P=.364). The odds ratio (95% confidence interval) of obtaining correct versus wrong answers with the device compared with without the device was 18.64 (7.94-43.77) at the 50-μm gap and 5.40 (0.25-114.25) at the 100-μm gap.
CONCLUSIONS: The study indicated that the paralleling device helped the clinician more accurately assess the implant-abutment junction with the 50- and 100-μm gaps.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2014        PMID: 24836280      PMCID: PMC5567837          DOI: 10.1016/j.prosdent.2014.03.016

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  17 in total

1.  Proposed method for the standardized measurement of marginal bone height on periapical radiographs with the Brånemark System.

Authors:  L Galasso
Journal:  Clin Implant Dent Relat Res       Date:  2000       Impact factor: 3.932

2.  On estimating the relation between blood group and disease.

Authors:  B WOOLF
Journal:  Ann Hum Genet       Date:  1955-06       Impact factor: 1.670

3.  A modified periapical radiographic holder used for standardized implant assessment.

Authors:  Nicholas Naffah; Jose Johann Chidiac
Journal:  J Prosthet Dent       Date:  2004-04       Impact factor: 3.426

4.  Estimation of angulation of Brånemark titanium fixtures from radiographic thread images.

Authors:  I P Sewerin
Journal:  Clin Oral Implants Res       Date:  1991 Jan-Mar       Impact factor: 5.977

5.  A radiograph positioning technique to evaluate prosthetic misfit and bone loss around implants.

Authors:  Kevin C Lin; Chandur P K Wadhwani; Arun Sharma; Frederick Finzen
Journal:  J Prosthet Dent       Date:  2013-11-14       Impact factor: 3.426

6.  Errors in radiographic assessment of marginal bone height around osseointegrated implants.

Authors:  I P Sewerin
Journal:  Scand J Dent Res       Date:  1990-10

7.  Factors influencing the preservation of the periimplant marginal bone.

Authors:  Frederic Hermann; Henriette Lerner; Ady Palti
Journal:  Implant Dent       Date:  2007-06       Impact factor: 2.454

8.  Radiographic verification of implant abutment seating.

Authors:  S M Cameron; A Joyce; J S Brousseau; M H Parker
Journal:  J Prosthet Dent       Date:  1998-03       Impact factor: 3.426

9.  An alternative holder for radiographic evaluation of tissue-integrated prostheses.

Authors:  J F Cox; M Pharoah
Journal:  J Prosthet Dent       Date:  1986-09       Impact factor: 3.426

10.  Radiographic assessment of the marginal fit of cast restorations.

Authors:  W Weyns; J De Boever
Journal:  J Prosthet Dent       Date:  1984-04       Impact factor: 3.426

View more
  1 in total

Review 1.  Etiology and Measurement of Peri-Implant Crestal Bone Loss (CBL).

Authors:  Adrien Naveau; Kouhei Shinmyouzu; Colman Moore; Limor Avivi-Arber; Jesse Jokerst; Sreenivas Koka
Journal:  J Clin Med       Date:  2019-02-01       Impact factor: 4.241

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.