Literature DB >> 9853488

Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: a retrieval study of 16 specimens.

V Psychoyios1, R W Crawford, J J O'Connor, D W Murray.   

Abstract

Many designs of unicompartmental knee replacement show early and mid-term failure due to polyethylene wear. We studied the wear rate of congruent polyethylene meniscal bearings retrieved from failed Oxford unicompartmental knee replacements. We examined 16 bearings, 0.8 to 12.8 years after implantation, measuring their thickness and comparing it with that of 14 unused bearings. The mean rate of penetration, which included the effects of wear at both upper and lower surfaces, was 0.036 mm per year (maximum 0.08). Bearings as thin as 3.5 mm wore no faster than thicker models, but ten with evidence of impingement had greater wear. The six bearings with no impingement showed a mean rate of penetration of 0.01 mm per year. In unicompartmental knee replacement, careful implantation of fully congruous meniscal bearings can avoid failure due to polyethylene wear.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9853488     DOI: 10.1302/0301-620x.80b6.8176

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  25 in total

1.  Dynamic in-vivo tibio-femoral and bearing motions in mobile bearing knee arthroplasty.

Authors:  S Fantozzi; A Leardini; S A Banks; M Marcacci; S Giannini; F Catani
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-07-09       Impact factor: 4.342

2.  [AMC unicondylar prosthesis].

Authors:  G Saxler; D Temmen; G Bontemps
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

3.  [Medial unicompartmental knee replacement using the "Oxford Uni" meniscal bearing knee].

Authors:  P R Aldinger; M Clarius; D W Murray; J W Goodfellow; S J Breusch
Journal:  Orthopade       Date:  2004-11       Impact factor: 1.087

4.  The Oxford unicompartmental knee prosthesis: an independent 10-year survival analysis.

Authors:  Peter Vorlat; Guy Putzeys; Dominique Cottenie; Tom Van Isacker; Nicole Pouliart; Frank Handelberg; Pierre-Paul Casteleyn; Filip Gheysen; René Verdonk
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-05-14       Impact factor: 4.342

5.  Severe metallosis after unicompartmental knee arthroplasty.

Authors:  Vicente Sanchis-Alfonso
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-10-07       Impact factor: 4.342

6.  Muscle activity around the knee and gait performance in unicompartmental knee arthroplasty patients: a comparative study on fixed- and mobile-bearing designs.

Authors:  Fabio Catani; Maria Grazia Benedetti; Luca Bianchi; Valentina Marchionni; Sandro Giannini; Alberto Leardini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-08-10       Impact factor: 4.342

7.  Clinical results of unicompartmental arthroplasty for knee osteoarthritis using a tibial component with screw fixation.

Authors:  Tomihisa Koshino; Koji Sato; Yusuke Umemoto; Yasushi Akamatsu; Ken Kumagai; Tomoyuki Saito
Journal:  Int Orthop       Date:  2014-10-24       Impact factor: 3.075

Review 8.  [Implant with a mobile or a fixed bearing in unicompartmental knee joint replacemen].

Authors:  G Matziolis; S Tohtz; B Gengenbach; C Perka
Journal:  Orthopade       Date:  2007-12       Impact factor: 1.087

9.  The risk of bearing dislocation in lateral unicompartmental knee arthroplasty using a mobile biconcave design.

Authors:  Sebastiaan Schelfaut; Lucas Beckers; Peter Verdonk; Johan Bellemans; Jan Victor
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-08-28       Impact factor: 4.342

10.  Oxford phase 3 unicondylar knee arthroplasty through a minimally invasive approach: long-term results.

Authors:  Omar Faour-Martín; Jose Antonio Valverde-García; Miguel Angel Martín-Ferrero; Aurelio Vega-Castrillo; María Angeles de la Red Gallego; Cesar C Suárez de Puga; Luis Amigo-Liñares
Journal:  Int Orthop       Date:  2013-03-17       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.