Literature DB >> 9848049

Perceived fidelity of compressed and reconstructed radiological images: a preliminary exploration of compression, luminance, and viewing distance.

T K Pilgram1, R M Slone, E Muka, J R Cox, G J Blaine.   

Abstract

The authors' goal was to explore the impact of image compression algorithm and ratio, image luminance, and viewing distance on radiologists' perception of reconstructed image fidelity. Five radiologists viewed 16 sets of four hard-copy chest radiographs prepared for secondary interpretation. Each set included one uncompressed, and three compressed and reconstructed images prepared using three different algorithms but the same compression ratio. The sets were prepared using two subjects, four compression ratios (10:1, 20:1, 30:1, 40:1), and two luminance levels (2,400 cd/m2, standard lightbox illumination, and 200 cd/m2, simulating a typical CRT display). Readers ranked image quality and evaluated obviousness and clinical importance of differences. Viewing distances for image screening, inspection, and comparison were recorded. At 10:1 compression, the compressed and uncompressed images were nearly indistinguishable; the three algorithms were very similar, and differences were rated "not obvious" and "not important." At higher compression, readers consistently preferred uncompressed images, with notable differences between algorithms. The obviousness and clinical importance of differences were rated higher at lightbox luminance. Viewing distances appeared to be idiosyncratic.

Mesh:

Year:  1998        PMID: 9848049      PMCID: PMC3453155          DOI: 10.1007/bf03178079

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  8 in total

1.  Data compression: effect on diagnostic accuracy in digital chest radiography.

Authors:  H MacMahon; K Doi; S Sanada; S M Montner; M L Giger; C E Metz; N Nakamori; F F Yin; X W Xu; H Yonekawa
Journal:  Radiology       Date:  1991-01       Impact factor: 11.105

2.  Selection of processing algorithms for digital image compression: a rank-order study.

Authors:  J M Holbert; M Staiger; T S Chang; J D Towers; C A Britton
Journal:  Acad Radiol       Date:  1995-04       Impact factor: 3.173

3.  An analytical look at the effects of compression on medical images.

Authors:  K Persons; P Palisson; A Manduca; B J Erickson; V Savcenko
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

4.  Image data compression.

Authors:  J M Bramble; H K Huang; M D Murphy
Journal:  Invest Radiol       Date:  1988-10       Impact factor: 6.016

5.  Irreversible data compression in chest imaging using computed radiography: an evaluation.

Authors:  T Mori; H Nakata
Journal:  J Thorac Imaging       Date:  1994       Impact factor: 3.000

6.  Application of wavelet compression to digitized radiographs.

Authors:  M A Goldberg; M Pivovarov; W W Mayo-Smith; M P Bhalla; J G Blickman; R T Bramson; G W Boland; H J Llewellyn; E Halpern
Journal:  AJR Am J Roentgenol       Date:  1994-08       Impact factor: 3.959

7.  The effect of irreversible image compression on diagnostic accuracy in thoracic imaging.

Authors:  D R Aberle; F Gleeson; J W Sayre; K Brown; P Batra; D A Young; B K Stewart; B K Ho; H K Huang
Journal:  Invest Radiol       Date:  1993-05       Impact factor: 6.016

8.  Clinical evaluation of irreversible image compression: analysis of chest imaging with computed radiography.

Authors:  T Ishigaki; S Sakuma; M Ikeda; Y Itoh; M Suzuki; S Iwai
Journal:  Radiology       Date:  1990-06       Impact factor: 11.105

  8 in total
  5 in total

1.  Diagnostic accuracy of film-based, TIFF, and wavelet compressed digital temporomandibular joint images.

Authors:  C J Trapnell; W C Scarfe; J H Cook; A M Silvejra; F J Regennitter; B S Haskell
Journal:  J Digit Imaging       Date:  2000-02       Impact factor: 4.056

2.  Seamless multiresolution display of portable wavelet-compressed images.

Authors:  M E Hovanes; J R Deal; A H Rowberg
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

3.  Proposal of a quality-index or metric for soft copy display systems: contrast sensitivity study.

Authors:  Jihong Wang; Ken Compton; Qi Peng
Journal:  J Digit Imaging       Date:  2003-09-11       Impact factor: 4.056

4.  Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold.

Authors:  Kyoung Ho Lee; Young Hoon Kim; Bo Hyoung Kim; Kil Joong Kim; Tae Jung Kim; Hyuk Jung Kim; Seokyung Hahn
Journal:  Eur Radiol       Date:  2006-11-22       Impact factor: 5.315

5.  Contrast sensitivity of digital imaging display systems: contrast threshold dependency on object type and implications for monitor quality assurance and quality control in PACS.

Authors:  Jihong Wang; Jun Xu; Veera Baladandayuthapani
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.