Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold.

Kyoung Ho Lee1, Young Hoon Kim, Bo Hyoung Kim, Kil Joong Kim, Tae Jung Kim, Hyuk Jung Kim, Seokyung Hahn.   

Abstract

To estimate the visually lossless threshold for Joint Photographic Experts Group (JPEG) 2000 compression of contrast-enhanced abdominal computed tomography (CT) images, 100 images were compressed to four different levels: a reversible (as negative control) and irreversible 5:1, 10:1, and 15:1. By alternately displaying the original and the compressed image on the same monitor, six radiologists independently determined if the compressed image was distinguishable from the original image. For each reader, we compared the proportion of the compressed images being rated distinguishable from the original images between the reversible compression and each of the three irreversible compressions using the exact test for paired proportions. For each reader, the proportion was not significantly different between the reversible (0-1%, 0/100 to 1/100) and irreversible 5:1 compression (0-3%). However, the proportion significantly increased with the irreversible 10:1 (95-99%) and 15:1 compressions (100%) versus reversible compression in all readers (P < 0.001); 100 and 95% of the 5:1 compressed images were rated indistinguishable from the original images by at least five of the six readers and all readers, respectively. Irreversibly 5:1 compressed abdominal CT images are visually lossless and, therefore, potentially acceptable for primary interpretation.

Mesh:

Substances:

Year:  2006        PMID: 17119972     DOI: 10.1007/s00330-006-0509-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  25 in total

1.  Assessment of visually lossless irreversible image compression: comparison of three methods by using an image-comparison workstation.

Authors:  R M Slone; D H Foos; B R Whiting; E Muka; D A Rubin; T K Pilgram; K S Kohm; S S Young; P Ho; D D Hendrickson
Journal:  Radiology       Date:  2000-05       Impact factor: 11.105

Review 2.  Data explosion: the challenge of multidetector-row CT.

Authors:  G D Rubin
Journal:  Eur J Radiol       Date:  2000-11       Impact factor: 3.528

3.  Evaluation of JPEG and wavelet compression of body CT images for direct digital teleradiologic transmission.

Authors:  A Kalyanpur; V P Neklesa; C R Taylor; A R Daftary; J A Brink
Journal:  Radiology       Date:  2000-12       Impact factor: 11.105

4.  Dose and pitch relationship for a particular multislice CT scanner.

Authors:  M Mahesh; J C Scatarige; J Cooper; E K Fishman
Journal:  AJR Am J Roentgenol       Date:  2001-12       Impact factor: 3.959

Review 5.  3-D imaging with MDCT.

Authors:  Geoffrey D Rubin
Journal:  Eur J Radiol       Date:  2003-03       Impact factor: 3.528

6.  Impact of multislice CT on PACS resources.

Authors:  Eric P Tamm; Steve Thompson; Steven L Venable; Kevin McEnery
Journal:  J Digit Imaging       Date:  2002-03-19       Impact factor: 4.056

7.  Two-sided confidence intervals for the single proportion: comparison of seven methods.

Authors:  R G Newcombe
Journal:  Stat Med       Date:  1998-04-30       Impact factor: 2.373

8.  Simplified exact analysis of case-referent studies: matched pairs; dichotomous exposure.

Authors:  F D Liddell
Journal:  J Epidemiol Community Health       Date:  1983-03       Impact factor: 3.710

9.  Effects of JPEG and wavelet compression of spiral low-dose ct images on detection of small lung cancers.

Authors:  F Li; S Sone; S Takashima; K Kiyono; Z G Yang; M Hasegawa; S Kawakami; A Saito; K Hanamura; K Asakura
Journal:  Acta Radiol       Date:  2001-03       Impact factor: 1.701

10.  Effect of CT digital image compression on detection of coronary artery calcification.

Authors:  L M Zheng; S Sone; Y Itani; Q Wang; K Hanamura; K Asakura; F Li; Z G Yang; J C Wang; T Funasaka
Journal:  Acta Radiol       Date:  2000-03       Impact factor: 1.701

View more
  3 in total

1.  Full-field digital mammography image data storage reduction using a crop tool.

Authors:  Bong Joo Kang; Sung Hun Kim; Yeong Yi An; Byung Gil Choi
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-06-10       Impact factor: 2.924

2.  Three-Dimensional Adaptive Image Compression Concept for Medical Imaging: Application to Computed Tomography Angiography for Peripheral Arteries.

Authors:  Guillaume Fahrni; David C Rotzinger; Chiaki Nakajo; Jamshid Dehmeshki; Salah Dine Qanadli
Journal:  J Cardiovasc Dev Dis       Date:  2022-04-27

3.  Development of an algorithm to automatically compress a CT image to visually lossless threshold.

Authors:  Chang-Mo Nam; Kyong Joon Lee; Yousun Ko; Kil Joong Kim; Bohyoung Kim; Kyoung Ho Lee
Journal:  BMC Med Imaging       Date:  2018-12-17       Impact factor: 1.930

  3 in total