Literature DB >> 2343125

Clinical evaluation of irreversible image compression: analysis of chest imaging with computed radiography.

T Ishigaki1, S Sakuma, M Ikeda, Y Itoh, M Suzuki, S Iwai.   

Abstract

To implement a picture archiving and communication system, clinical evaluation of irreversible image compression with a newly developed modified two-dimensional discrete cosine transform (DCT) and bit-allocation technique was performed for chest images with computed radiography (CR). CR images were observed on a cathode-ray-tube monitor in a 1,024 X 1,536 matrix. One original and five reconstructed versions of the same images with compression ratios of 3:1, 6:1, 13:1, 19:1, and 31:1 were ranked according to quality. Test images with higher spatial frequency were ranked better than those with lower spatial frequency and the acceptable upper limit of the compression ratio was 19:1. In studies of receiver operating characteristics for scoring the presence or absence of nodules and linear shadows, the images with a compression ratio of 25:1 showed a statistical difference as compared with the other images with a compression ratio of 20:1 or less. Both studies show that plain CR chest images with a compression ratio of 10:1 are acceptable and, with use of an improved DCT technique, the upper limit of the compression ratio is 20:1.

Entities:  

Mesh:

Year:  1990        PMID: 2343125     DOI: 10.1148/radiology.175.3.2343125

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Image compression and chest radiograph interpretation: image perception comparison between uncompressed chest radiographs and chest radiographs stored using 10:1 JPEG compression.

Authors:  D P Beall; P D Shelton; T V Kinsey; M C Horton; B J Fortman; S Achenbach; V Smirnoff; D L Courneya; B Carpenter; J T Gironda
Journal:  J Digit Imaging       Date:  2000-05       Impact factor: 4.056

2.  Irreversible compression of medical images.

Authors:  Bradley J Erickson
Journal:  J Digit Imaging       Date:  2002-04-30       Impact factor: 4.056

3.  Image data compression using a new floating-point digital signal processor.

Authors:  E L Siegel; A W Templeton; K L Hensley; M A McFadden; K G Baxter; M D Murphey; P E Cronin; R G Gesell; S J Dwyer
Journal:  J Digit Imaging       Date:  1991-08       Impact factor: 4.056

4.  Clinical evaluation of irreversible data compression for computed radiography of the hand.

Authors:  K Uchida; H Watanabe; T Aoki; K Nakamura; H Nakata
Journal:  J Digit Imaging       Date:  1998-08       Impact factor: 4.056

5.  Perceived fidelity of compressed and reconstructed radiological images: a preliminary exploration of compression, luminance, and viewing distance.

Authors:  T K Pilgram; R M Slone; E Muka; J R Cox; G J Blaine
Journal:  J Digit Imaging       Date:  1998-11       Impact factor: 4.056

6.  Clinical evaluation of irreversible data compression for computed radiography in excretory urography.

Authors:  K Uchida; K Nakamura; H Watanabe; K Egashira; Y Ishino; M Murakami; H Nakata
Journal:  J Digit Imaging       Date:  1996-08       Impact factor: 4.056

7.  Evaluation of irreversible compression of digitized posterior-anterior chest radiographs.

Authors:  B J Erickson; A Manduca; K R Persons; F Earnest; T E Hartman; G F Harms; L R Brown
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

8.  Evaluation of the medical diagnostic imaging support system based on 2 years of clinical experience.

Authors:  D V Smith; S Smith; G N Bender; J R Carter; Y Kim; M A Cawthon; R G Leckie; J C Weiser; J Romlein; F Goeringer
Journal:  J Digit Imaging       Date:  1995-05       Impact factor: 4.056

9.  Building a medical multimedia database system to integrate clinical information: an application of high-performance computing and communications technology.

Authors:  H J Lowe; B G Buchanan; G F Cooper; J K Vries
Journal:  Bull Med Libr Assoc       Date:  1995-01

10.  Clinical evaluation of irreversible data compression for computed radiography of the chest.

Authors:  K Egashira; H Nakata; H Watanabe; K Uchida; K Nakamura; Y Ishino; K Horino; R Yoshikawa
Journal:  J Digit Imaging       Date:  1998-11       Impact factor: 4.056

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.