Literature DB >> 9846905

Finite element analysis of non-axial versus axial loading of oral implants in the mandible of the dog.

L Barbier1, J Vander Sloten, G Krzesinski, E Schepers, G Van der Perre.   

Abstract

The influence of axial and non-axial occlusal loads on the bone remodelling phenomena around oral implants in an animal experiment is simulated in a finite element analysis. The axial and non-axial loading conditions were introduced by inserting a bilaterally supported fixed partial prosthesis and a cantilever fixed partial prosthesis on two IMZ implants in the mandible of beagle dogs. Earlier quantitative and qualitative histological analyses revealed a statistically significant different remodelling response between both loading conditions. Two-dimensional and three-dimensional models are built to analyse and compare von Mises equivalent stress, maximum principal stress, maximum principal strain and strain energy density distributions, first around a free-standing implant and subsequently around the implants of the two prosthesis designs under the respective resultant in vivo loads. Strong correlations between the calculated stress distributions in the surrounding bone tissue and the remodelling phenomena in the comparative animal model are observed. It is concluded that the highest bone remodelling events coincide with the regions of highest equivalent stress and that the major remodelling differences between axial and non-axial loading are largely determined by the horizontal stress component of the engendered stresses.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9846905     DOI: 10.1046/j.1365-2842.1998.00318.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  16 in total

1.  Microchemical transformation of bioactive glass particles of narrow size range, a 0-24 months study.

Authors:  A Huygh; E J G Schepers; L Barbier; P Ducheyne
Journal:  J Mater Sci Mater Med       Date:  2002-03       Impact factor: 3.896

2.  Impact of peri-implant bone resorption, prosthetic materials, and crown to implant ratio on the stress distribution of short implants: a finite element analysis.

Authors:  Pinar Ercal; Aysegul Erten Taysi; Demet Cagil Ayvalioglu; Meltem Mert Eren; Soner Sismanoglu
Journal:  Med Biol Eng Comput       Date:  2021-03-17       Impact factor: 2.602

3.  Three-dimensional finite element analysis of platform switched implant.

Authors:  Se-Young Moon; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

4.  Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

Authors:  W Aunmeungtong; P Khongkhunthian; P Rungsiyakull
Journal:  Oral Implantol (Rome)       Date:  2016-11-16

5.  Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading.

Authors:  Sarah C Woodford; Dale L Robinson; Cornelia Edelmann; Albert Mehl; Oliver Röhrle; Peter Vee Sin Lee; David C Ackland
Journal:  Ann Biomed Eng       Date:  2021-01-06       Impact factor: 3.934

6.  Influence of Implant Surface Topography and Loading Condition on Stress Distribution in Bone Around Implants: A Comparative 3D FEA.

Authors:  Ravindra C Savadi; Jatin Agarwal; Rolly Shrivastava Agarwal; V Rangarajan
Journal:  J Indian Prosthodont Soc       Date:  2011-10-19

7.  Angulated abutments and perimplants stress: F.E.M. analysis.

Authors:  P Cardelli; M Montani; M Gallio; M Biancolini; C Brutti; A Barlattani
Journal:  Oral Implantol (Rome)       Date:  2009-12-10

8.  Evaluation of Stress Pattern Caused by Mini-Implant in Mandibular Alveolar Bone with Different Angulations and Retraction Forces: A Three-Dimensional Finite Element Study.

Authors:  Manreet Sidhu; Vinay Kumar Chugh; Kuldeep Dmello; Anurag Mehta; Ankita Chugh; Pradeep Tandon
Journal:  Turk J Orthod       Date:  2020-07-18

Review 9.  Biomechanics of oral mucosa.

Authors:  Junning Chen; Rohana Ahmad; Wei Li; Michael Swain; Qing Li
Journal:  J R Soc Interface       Date:  2015-08-06       Impact factor: 4.118

10.  Periodontal ligament influence on the stress distribution in a removable partial denture supported by implant: a finite element analysis.

Authors:  Carlos Marcelo Archangelo; Eduardo Passos Rocha; João Antônio Pereira; Manoel Martin Junior; Rodolfo Bruniera Anchieta; Amilcar Chagas Freitas Júnior
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.