Literature DB >> 9829238

Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise.

J Hsieh1.   

Abstract

The quality of a computed tomography (CT) image is often degraded by streaking artifacts resulting from excessive x-ray quantum noise. Often, a patient has to be rescanned at a higher technique or at a larger slice thickness in order to obtain an acceptable image for diagnosis. This results in a higher dose to the patient, a degraded cross plane resolution, or a reduced patient throughput. In this paper, we propose an adaptive filtering approach in Radon space based on the local statistical properties of the CT projections. We first model the noise characteristics of a projection sample undergoing important preprocessing steps. A filter is then designed such that its parameters are dynamically adjusted to adapt to the local noise characteristics. Because of the adaptive nature of the filter, a proper balance between streak artifact suppression and spatial resolution preservation is achieved. Phantom and clinical studies have been conducted to evaluate the robustness of our approach. Results demonstrate that the adaptive filtering approach is effective in reducing or eliminating quantum noise induced artifacts in CT. At the same time, the impact on the spatial resolution is kept at a low level.

Entities:  

Mesh:

Year:  1998        PMID: 9829238     DOI: 10.1118/1.598410

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  62 in total

1.  A pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images.

Authors:  Oliver Watzke; Willi A Kalender
Journal:  Eur Radiol       Date:  2004-03-11       Impact factor: 5.315

2.  Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT.

Authors:  Andreas Maier; Lars Wigstrom; Hannes G Hofmann; Joachim Hornegger; Lei Zhu; Norbert Strobel; Rebecca Fahrig
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Low-dose computed tomography image restoration using previous normal-dose scan.

Authors:  Jianhua Ma; Jing Huang; Qianjin Feng; Hua Zhang; Hongbing Lu; Zhengrong Liang; Wufan Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

4.  Evaluation of the accuracy of CT numbers in statistical correction of nonlinearity for polychromatic X-ray CT projection data.

Authors:  Shin-ichiro Iwamoto; Akira Shiozaki
Journal:  Radiol Phys Technol       Date:  2008-07-03

5.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

6.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

7.  Penalized weighted least-squares approach to sinogram noise reduction and image reconstruction for low-dose X-ray computed tomography.

Authors:  Jing Wang; Tianfang Li; Hongbing Lu; Zhengrong Liang
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

8.  Multiscale penalized weighted least-squares sinogram restoration for low-dose X-ray computed tomography.

Authors:  Jing Wang; Zhengrong Liang; Hongbing Lu
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2006

9.  Improvement of image quality of multislice spiral CT scans of the head and neck region using a raw data-based multidimensional adaptive filtering (MAF) technique.

Authors:  Ulrich Baum; Katharina Anders; Gregor Steinbichler; Michael Lell; Holger Greess; Thomas Riedel; Marc Kachelriess; Willi A Kalender; Werner A Bautz
Journal:  Eur Radiol       Date:  2004-08-24       Impact factor: 5.315

10.  Dedicated breast computed tomography: volume image denoising via a partial-diffusion equation based technique.

Authors:  Jessie Q Xia; Joseph Y Lo; Kai Yang; Carey E Floyd; John M Boone
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.