Literature DB >> 9809271

The derivation of theoretical ultrasonic Doppler blood flow spectrum.

N F Güler1, S Ozer.   

Abstract

This paper deals with theoretical aspects of blood flow and the ultrasonic Doppler spectrum. Blood flow in the vessel can be considered as a pipe flow with a circular cross-section. Blood flow is, in general, complex and pulsatile. Navier-Stokes and the continuity equations are the governing equations for the blood flow, and the Navier's equations for the blood vessel. If the flow is pulsatile with a large Womersely number, the velocity profile becomes blunt due to the inertia forces. Since the ultrasonic Doppler flowmeter detects the velocities of blood cells across the vessel, Doppler power spectrum is dependent on the velocity profile. If the velocity profile is blunt, the Doppler power spectrum will be narrow banded. If the flow is sinusoidal, the Womersely number is only a parameter describing the pulsatility. Blood flow waveforms, however, differ from the sinusoidal wave. They consist of a steady flow component and many harmonics with amplitudes and phases. In this study, the influence of the harmonic contents and the Womersely number on velocity profiles and the Doppler power spectrum are examined.

Entities:  

Mesh:

Year:  1998        PMID: 9809271     DOI: 10.1023/a:1020573926616

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  7 in total

1.  Calculation of Doppler spectral power density functions.

Authors:  G K Aldis; R S Thompson
Journal:  IEEE Trans Biomed Eng       Date:  1992-10       Impact factor: 4.538

2.  Method for the calculation of velocity, rate of flow and viscous drag in arteries when the pressure gradient is known.

Authors:  J R WOMERSLEY
Journal:  J Physiol       Date:  1955-03-28       Impact factor: 5.182

3.  Application of autoregressive and Fast Fourier Transform spectral analysis to tricuspid and mitral valve stenosis.

Authors:  I Güler; S Kara; N F Güler; M K Kiymik
Journal:  Comput Methods Programs Biomed       Date:  1996-01       Impact factor: 5.428

4.  Effects of transducer beam geometry and flow velocity profile on the Doppler power spectrum: a theoretical study.

Authors:  P A Bascom; R S Cobbold
Journal:  Ultrasound Med Biol       Date:  1990       Impact factor: 2.998

5.  Theory of ultrasound Doppler-spectra velocimetry for arbitrary beam and flow configurations.

Authors:  D Censor; V L Newhouse; T Vontz; H V Ortega
Journal:  IEEE Trans Biomed Eng       Date:  1988-09       Impact factor: 4.538

Review 6.  Measurement of blood flow by ultrasound: accuracy and sources of error.

Authors:  R W Gill
Journal:  Ultrasound Med Biol       Date:  1985 Jul-Aug       Impact factor: 2.998

7.  Comparison of time-frequency distribution techniques for analysis of simulated Doppler ultrasound signals of the femoral artery.

Authors:  Z Guo; L G Durand; H C Lee
Journal:  IEEE Trans Biomed Eng       Date:  1994-04       Impact factor: 4.538

  7 in total
  1 in total

1.  Tissue blood flow assessment of pulsed Doppler ultrasound using autoregressive modeling.

Authors:  O F Bay; I Güler
Journal:  J Med Syst       Date:  1999-02       Impact factor: 4.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.