Literature DB >> 2931884

Measurement of blood flow by ultrasound: accuracy and sources of error.

R W Gill.   

Abstract

Doppler ultrasound has now developed to the point where the rate of flow of blood in a given vessel can be measured with appropriate instrumentation. The theoretical basis of Doppler flow measurement is reviewed in this paper, with particular emphasis on the potential and actual sources of error. Three distinct approaches are identified, and the strengths and weaknesses of each discussed. The separate errors involved in estimating the vessel cross-sectional area, the angle of approach, and the Doppler shift are analyzed, together with the question of the uniformity of scattering from the blood. In vivo and in vitro tests of the accuracy obtained using a number of Doppler flow measuring instruments are then reviewed. It is concluded that the Doppler methods are capable of good absolute accuracy when suitably designed equipment is used in appropriate situations, with systematic errors of 6% of less. There are, however, considerable random errors, attributable primarily to errors in measuring the cross-sectional area and the angle of approach. Repeating the measurement of flow several times and averaging the results can reduce these random errors to an acceptable level.

Mesh:

Year:  1985        PMID: 2931884     DOI: 10.1016/0301-5629(85)90035-3

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  105 in total

1.  Mechanisms of blood pressure increase induced by dopamine in hypotensive preterm neonates.

Authors:  J Zhang; D J Penny; N S Kim; V Y Yu; J J Smolich
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1999-09       Impact factor: 5.747

2.  Handgrip exercise increases postocclusion hyperaemic brachial artery dilatation.

Authors:  S Agewall; G A Whalley; R N Doughty; N Sharpe
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

3.  In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI.

Authors:  Fabian Rengier; Michael Delles; Roland Unterhinninghofen; Sebastian Ley; Matthias Müller-Eschner; Sasan Partovi; Philipp Geisbüsch; Rüdiger Dillmann; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

Review 4.  Review of optical coherence tomography based angiography in neuroscience.

Authors:  Utku Baran; Ruikang K Wang
Journal:  Neurophotonics       Date:  2016-01-20       Impact factor: 3.593

5.  Measurement of normal portal venous blood flow by Doppler ultrasound.

Authors:  H S Brown; M Halliwell; M Qamar; A E Read; J M Evans; P N Wells
Journal:  Gut       Date:  1989-04       Impact factor: 23.059

6.  Changes in mesenteric venous flow due to celiac sprue.

Authors:  L Bolondi; S Li Bassi; S Gaiani; G Zironi; G F Paparo; L Barbara
Journal:  Dig Dis Sci       Date:  1992-06       Impact factor: 3.199

7.  Hepatic perfusion changes in patients with liver metastases: comparison with those patients with cirrhosis.

Authors:  E Leen; J A Goldberg; J R Anderson; J Robertson; B Moule; T G Cooke; C S McArdle
Journal:  Gut       Date:  1993-04       Impact factor: 23.059

8.  A Survey of Challenges and Opportunities in Sensing and Analytics for Risk Factors of Cardiovascular Disorders.

Authors:  Nathan C Hurley; Erica S Spatz; Harlan M Krumholz; Roozbeh Jafari; Bobak J Mortazavi
Journal:  ACM Trans Comput Healthc       Date:  2020-12-30

9.  Efficient method for volumetric assessment of peak blood flow velocity using 4D flow MRI.

Authors:  Michael J Rose; Kelly Jarvis; Varun Chowdhary; Alex J Barker; Bradley D Allen; Joshua D Robinson; Michael Markl; Cynthia K Rigsby; Susanne Schnell
Journal:  J Magn Reson Imaging       Date:  2016-05-18       Impact factor: 4.813

10.  Minimizing Measurement Variability in Carotid Ultrasound Evaluations.

Authors:  Jon-Emile S Kenny; Maxime Cannesson; Igor Barjaktarevic
Journal:  J Ultrasound Med       Date:  2020-08-24       Impact factor: 2.153

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.