Literature DB >> 8646836

Application of autoregressive and Fast Fourier Transform spectral analysis to tricuspid and mitral valve stenosis.

I Güler1, S Kara, N F Güler, M K Kiymik.   

Abstract

Tricuspid and mitral valve flow area was determined from an apical four-chamber view. Doppler signals were recorded from normal subjects and patients with tricuspid and mitral valve stenosis by using a pulsed Doppler unit. The location of sample volume was chosen at the ventricular side of the valve orifice and within the right ventricular tract. This was done with the aid of an integrated cardiac imaging facility. The analog signal at the output of the Doppler unit was sampled and digitized using an analog/digital interface board and transferred to a personal computer. The data were then analyzed using the Fast Fourier Transform (FTT) and autoregressive (AR) modeling methods of spectral analysis and all the sonograms were obtained. Statistical comparison between the FFT and AR methods was made. The results show that the AR method offers a superior performance over the FFT method as regards the assessment of tricuspid and mitral valve stenosis.

Entities:  

Mesh:

Year:  1996        PMID: 8646836     DOI: 10.1016/0169-2607(95)01702-x

Source DB:  PubMed          Journal:  Comput Methods Programs Biomed        ISSN: 0169-2607            Impact factor:   5.428


  12 in total

1.  Software development for medical instrumentation.

Authors:  N F Güler
Journal:  J Med Syst       Date:  2001-02       Impact factor: 4.460

2.  Tissue blood flow assessment of pulsed Doppler ultrasound using autoregressive modeling.

Authors:  O F Bay; I Güler
Journal:  J Med Syst       Date:  1999-02       Impact factor: 4.460

3.  Determination of stenosis and occlusion in arteries with the application of FFT, AR, and ARMA methods.

Authors:  Elif Derya Ubeyli; Inan Güler
Journal:  J Med Syst       Date:  2003-04       Impact factor: 4.460

4.  Application of FFT-analyzed umbilical artery doppler signals to fuzzy algorithm.

Authors:  Fýrat Hardalaç; Aydan Biri; Ayhan Sucak
Journal:  J Med Syst       Date:  2004-12       Impact factor: 4.460

5.  The derivation of theoretical ultrasonic Doppler blood flow spectrum.

Authors:  N F Güler; S Ozer
Journal:  J Med Syst       Date:  1998-10       Impact factor: 4.460

6.  Design parameters of pulsed wave ultrasonic Doppler blood flowmeter.

Authors:  I Güler; Y Savaş
Journal:  J Med Syst       Date:  1998-08       Impact factor: 4.460

7.  Classification of aorta insufficiency and stenosis using neuro-fuzzy system.

Authors:  Necaattin Barşçi; Ergün Topal; Firat Hardalaç; Inan Güler
Journal:  J Med Syst       Date:  2005-04       Impact factor: 4.460

8.  Correlation dimension analysis of Doppler signals in children with aortic valve disorders.

Authors:  Derya Yılmaz; N Fatma Güler
Journal:  J Med Syst       Date:  2009-05-15       Impact factor: 4.460

9.  Comparison of short-time Fourier transform and Eigenvector MUSIC methods using discrete wavelet transform for diagnosis of atherosclerosis.

Authors:  Fatma Latifoğlu; Sadik Kara; Erkan Imal
Journal:  J Med Syst       Date:  2009-06       Impact factor: 4.460

10.  A classification system for stenosis from mitral valve Doppler signals using adaptive network based fuzzy inference system.

Authors:  Mahmut Tokmakçi
Journal:  J Med Syst       Date:  2007-10       Impact factor: 4.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.