Literature DB >> 15682368

Gated SPECT assessment of left ventricular function is sensitive to small patient motions and to low rates of triggering errors: a comparison with equilibrium radionuclide angiography.

Wassila Djaballah1, Marc A Muller, Anne C Bertrand, Pierre Y Marie, Bernard Chalon, Karim Djaballah, Pierre Olivier, Andreï Codreanu, Gilles Karcher, Alain Bertrand.   

Abstract

BACKGROUND: Patient displacements and errors in R-wave detection are the main causes of inaccurate acquisition for gated single photon emission computed tomography (SPECT) and equilibrium radionuclide angiography (RNA). This study aimed to compare the influences of both factors between gated SPECT and RNA determinations of left ventricular ejection fraction. METHODS AND
RESULTS: On gated SPECT and RNA acquisitions, recorded in 20 patients with coronary artery disease, we simulated the consequences of (1) 3-dimensional patient displacements of low (6.7 mm), moderate (13.4 mm), and high amplitude (20.1 mm) and (2) an erroneous triggering on T waves in 10% to 40% of recorded beats. Absolute values of left ventricular ejection fraction changes from baseline were higher with gated SPECT compared with RNA for patient displacements of low amplitude (5.0% +/- 3.8% vs 1.2% +/- 0.9%, P < .001) or moderate amplitude (10.0% +/- 6.2% vs 3.0% +/- 2.3%, P = .001) but not for patient displacements of high amplitude (12% +/- 9% vs 9% +/- 7%, P = not significant) and inaccurate triggering (for 20% T-wave triggering, 8.9% +/- 3.6% vs 7.9% +/- 3.0%; P = not significant).
CONCLUSION: Contrary to RNA, gated SPECT is vulnerable to small patient displacements, and thus, specific efforts might be useful for limiting this potential cause of erroneous results. Both techniques may be affected by low rates of triggering errors, suggesting that small acceptance windows on cycle length should be recommended not only for RNA but also for gated SPECT.

Entities:  

Mesh:

Year:  2005        PMID: 15682368     DOI: 10.1016/j.nuclcard.2004.08.008

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  33 in total

1.  201Tl SPECT abnormalities, documented at rest in dilated cardiomyopathy, are related to a lower than normal myocardial thickness but not to an excess in myocardial wall stress.

Authors:  Nathalie Hassan; Jean-Marie Escanyé; Yves Juillière; Pierre-Yves Marie; Nicolas David; Pierre Olivier; Adey Ayalew; Gilles Karcher; Jean-François Stolz; Alain Bertrand
Journal:  J Nucl Med       Date:  2002-04       Impact factor: 10.057

2.  Performance of OSEM and depth-dependent resolution recovery algorithms for the evaluation of global left ventricular function in 201Tl gated myocardial perfusion SPECT.

Authors:  Doumit Daou; Isabelle Pointurier; Carlos Coaguila; Didier Vilain; Abdel Wahab Benada; Rachida Lebtahi; Thierry Fourme; Michel Slama; Dominique Le Guludec
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

Review 3.  Automatic analysis of ventricular function by nuclear imaging.

Authors:  G Germano
Journal:  Curr Opin Cardiol       Date:  1998-11       Impact factor: 2.161

4.  Long-term prediction of major ischemic events by exercise thallium-201 single-photon emission computed tomography. Incremental prognostic value compared with clinical, exercise testing, catheterization and radionuclide angiographic data.

Authors:  P Y Marie; N Danchin; J F Durand; L Feldmann; A Grentzinger; P Olivier; G Karcher; Y Juillière; J M Virion; D Beurrier
Journal:  J Am Coll Cardiol       Date:  1995-10       Impact factor: 24.094

5.  Determination of left ventricular volume and mass with use of biphasic spin-echo MR imaging: comparison with cine MR.

Authors:  G R Caputo; J Suzuki; C Kondo; H Cho; R A Quaife; C B Higgins; D L Parker
Journal:  Radiology       Date:  1990-12       Impact factor: 11.105

6.  Dipyridamole and exercise SPET provide different estimates of myocardial ischaemic areas: role of the severity of coronary stenoses and of the increase in heart rate during exercise.

Authors:  N David; P Y Marie; M Angioi; R M Rodriguez; N Hassan; P Olivier; A Grentzinger; G Karcher; O Claudon; Y Juillière; N Danchin; A Bertrand
Journal:  Eur J Nucl Med       Date:  2000-07

7.  Gated myocardial perfusion tomography for the assessment of left ventricular function and volumes: comparison with echocardiography.

Authors:  E Cwajg; J Cwajg; Z X He; W S Hwang; F Keng; S F Nagueh; M S Verani
Journal:  J Nucl Med       Date:  1999-11       Impact factor: 10.057

8.  Accuracy of left ventricular ejection fraction determined by gated myocardial perfusion SPECT with Tl-201 and Tc-99m sestamibi: comparison with first-pass radionuclide angiography.

Authors:  Z X He; E Cwajg; J S Preslar; J J Mahmarian; M S Verani
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

9.  Quantitative evaluation of a comprehensive motion, resolution, and attenuation correction program: initial experience.

Authors:  P Rigo; P Van Boxem; J Foulon; M Safi; J Engdahl; J Links
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

10.  Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion.

Authors:  R Eisner; A Churchwell; T Noever; D Nowak; K Cloninger; D Dunn; W Carlson; J Oates; J Jones; D Morris
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

View more
  3 in total

1.  Left ventricular ejection fraction determined with the simulation of a very low-dose CZT-SPECT protocol and an additional count-calibration on planar radionuclide angiographic data.

Authors:  Hubert Tissot; Véronique Roch; Olivier Morel; Nicolas Veran; Mathieu Perrin; Marine Claudin; Antoine Verger; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2019-02-27       Impact factor: 5.952

2.  Nitrate-enhanced gated SPECT in patients with primary angioplasty for acute myocardial infarction: evidence of a reversible and nitrate-sensitive impairment of myocardial perfusion.

Authors:  Wassila Djaballah; Marc A Muller; Michael Angioï; Frédéric Moulin; Andrei Codreanu; Damien Mandry; Gérard Ethevenot; Gilles Karcher; Etienne Aliot; Pierre Y Marie
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07-31       Impact factor: 9.236

3.  Motion correction and myocardial perfusion SPECT using manufacturer provided software. Does it affect image interpretation?

Authors:  Teresa Massardo; Rodrigo Jaimovich; Ricardo Faure; Manuel Muñoz; Rita Alay; Héctor Gatica
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-11-14       Impact factor: 9.236

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.