Literature DB >> 9787354

Positive correlation between Tono-Pen intraocular pressure and central corneal thickness.

A A Dohadwala1, R Munger, K F Damji.   

Abstract

OBJECTIVE: To examine the relationship between intraocular pressure (IOP) readings taken by the Tono-Pen tonometer (Mentor O&O, Norwell, MA) and central corneal thickness (CCT).
DESIGN: Prospective cross-sectional population study. PARTICIPANTS: There were 651 eyes of 332 healthy subjects. MAIN OUTCOME MEASURES: A questionnaire was given to each subject requesting information on gender, age, race, and other factors that can influence IOP. The IOP then was measured using the Tono-Pen followed by measurements of CCT using an ultrasonic pachymeter.
RESULTS: The IOP was found to increase by 2.9 mmHg/100 microns CCT in males and 1.2 mmHg/100 microns in females. For males, CCT was found to be statistically significant in predicting IOP (P < 0.001 in the right and left eyes) and diabetes was of borderline significance (P = 0.012 in the right eye, P = 0.089 in the left eye). For females, CCT was of borderline significance (P = 0.064 in the right eye, P = 0.019 in the left eye). In females, a family history of glaucoma (P = 0.021 in the right eye, P = 0.022 in the left eye) and hypertension (P = 0.010 in the right eye, P = < 0.001 in the left eye) were also significant in the prediction of IOP. Race was found to be a significant predictor of CCT (P < 0.001 in both right and left eyes) for both males and females.
CONCLUSION: Clinicians should be aware that, as with the Goldmann applanation tonometer, the Tono-Pen has a systematic error in IOP readings caused by its dependence on CCT. Tono-Pen IOP readings are positively correlated to CCT in males and, to a lesser extent, in females as well. The CCT measurements should be considered to ensure proper interpretation of IOP measurements in the diagnosis and management of disorders in which the CCT or IOP readings are outside normal limits.

Entities:  

Mesh:

Year:  1998        PMID: 9787354     DOI: 10.1016/S0161-6420(98)91029-6

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  21 in total

1.  The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen XL, and Goldmann applanation tonometry.

Authors:  P-A Tonnu; T Ho; T Newson; A El Sheikh; K Sharma; E White; C Bunce; D Garway-Heath
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

2.  Central corneal thickness in southern Egypt.

Authors:  Engy Mohamed Mostafa
Journal:  Int Ophthalmol       Date:  2013-11-22       Impact factor: 2.031

3.  Central corneal thickness does not correlate with TonoLab-measured IOP in several mouse strains with single transgenic mutations of matricellular proteins.

Authors:  Ayan Chatterjee; Dong-Jin Oh; Min Hyung Kang; Douglas J Rhee
Journal:  Exp Eye Res       Date:  2013-06-24       Impact factor: 3.467

Review 4.  Tonometers-which one should I use?

Authors:  Kanza Aziz; David S Friedman
Journal:  Eye (Lond)       Date:  2018-02-19       Impact factor: 3.775

5.  Comparative evaluation of TonoPen AVIA, Goldmann applanation tonometry and non-contact tonometry.

Authors:  Shibal Bhartiya; Shveta Jindal Bali; Reetika Sharma; Neha Chaturvedi; Tanuj Dada
Journal:  Int Ophthalmol       Date:  2011-07-15       Impact factor: 2.031

Review 6.  The thick and thin of the central corneal thickness in glaucoma.

Authors:  Graham W Belovay; Ivan Goldberg
Journal:  Eye (Lond)       Date:  2018-02-15       Impact factor: 3.775

7.  The effect of corneal thickness on intraocular pressure measurement in patients with corneal pathology.

Authors:  A C Browning; A Bhan; A P Rotchford; S Shah; H S Dua
Journal:  Br J Ophthalmol       Date:  2004-11       Impact factor: 4.638

8.  Central corneal thickness in Japanese children.

Authors:  Akiko Hikoya; Miho Sato; Kinnichi Tsuzuki; Yuka Maruyama Koide; Ryo Asaoka; Yoshihiro Hotta
Journal:  Jpn J Ophthalmol       Date:  2009-01-30       Impact factor: 2.447

9.  Comparison of intraocular tonometry using three different non-invasive tonometers in children.

Authors:  Julia Lasseck; Thomas Jehle; Nicolas Feltgen; Wolf Alexander Lagrèze
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-06-14       Impact factor: 3.117

10.  Relationship of central corneal thickness to postural IOP changes in patients with and without glaucoma in southern India.

Authors:  Stephen J Moster; Ghasem Fakhraie; Rengaraj Venketesh; Mark L Moster; Yuanjun Zhao; Marlene R Moster
Journal:  Int Ophthalmol       Date:  2012-05-11       Impact factor: 2.031

View more