Literature DB >> 9769011

Transit-time flow measurement for detection of early graft failure during myocardial revascularization.

B H Walpoth1, A Bosshard, I Genyk, B Kipfer, P A Berdat, O M Hess, U Althaus, T P Carrel.   

Abstract

BACKGROUND: A low-flow situation in arterial and venous grafts has been associated with high rates of perioperative infarction and mortality. This study was designed to look at intraoperative graft flow and resistance in patients with coronary artery disease.
METHODS: Coronary artery bypass graft flow was measured in 46 patients. Transit-time flow was used for coronary flow measurements at rest as well as after maximal vasodilation with adenosine infusion.
RESULTS: Forty-three of the 46 patients showed normal internal mammary artery graft flow (>20 mL/min); 3 patients had no or minimal graft flow. Redoing the graft anastomosis in these 3 patients resulted in normalization of graft flow. The mean flow increased significantly after correction from 0.5 +/- 0.7 mL/min to 15.7 +/- 9.6 mL/min (p < 0.02). Conversely, vascular resistance decreased significantly from 138 +/- 10 to 4.8 +/- 1.8 Ohmv (p < 0.0001), as did the pulsatility index (from 146.9 +/- 95.7 to 3.4 +/- 1.8; p < 0.001). After correction, coronary flow reserve was 2.5 +/- 1.1.
CONCLUSIONS: Measurements of intraoperative flow and resistance as well as derived variables allow assessment of early graft function and thus help prevent graft failure and reduce perioperative infarction. Transit-time volume flow might be a simple tool for quality control in coronary bypass procedures.

Entities:  

Mesh:

Year:  1998        PMID: 9769011     DOI: 10.1016/s0003-4975(98)00653-5

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  21 in total

Review 1.  Left internal mammary artery grafting to left anterior descending coronary artery by minimally invasive direct coronary artery bypass approach.

Authors:  A Diegeler
Journal:  Curr Cardiol Rep       Date:  1999-11       Impact factor: 2.931

2.  Intraoperative assessment and quantification of coronary artery graft patency performed on or off cardiopulmonary bypass.

Authors:  Eric D Rauch; Christopher Leach; Terry Barnes; Kurt Driscoll; Kurt Strutz; David W Holt
Journal:  J Extra Corpor Technol       Date:  2007-06

3.  Radial artery achieves better flowmetric results than saphenous vein in the elderly.

Authors:  Giuseppe Santarpino; Francesco Onorati; Cristian Scalas; Marco De Gori; Lucia Cristodoro; Saverio Zofrea; Attilio Renzulli
Journal:  Heart Vessels       Date:  2009-04-01       Impact factor: 2.037

4.  The application of intraoperative transit time flow measurement to accurately assess anastomotic quality in sequential vein grafting.

Authors:  Yang Yu; Fan Zhang; Ming-Xin Gao; Hai-Tao Li; Jing-Xing Li; Wei Song; Xin-Sheng Huang; Cheng-Xiong Gu
Journal:  Interact Cardiovasc Thorac Surg       Date:  2013-09-01

5.  Comparison of the waveforms of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency.

Authors:  Atsutoshi Hatada; Yoshitaka Okamura; Masahiro Kaneko; Takahiro Hisaoka; Shuji Yamamoto; Takeshi Hiramatsu; Yoshiharu Nishimura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2011-01-12

6.  The use of intraoperative graft assessment in guiding graft revision.

Authors:  Teresa M Kieser; David P Taggart
Journal:  Ann Cardiothorac Surg       Date:  2018-09

7.  Dobutamine stress echocardiography for the detection of myocardial viability in patients with left ventricular dysfunction taking beta blockers: accuracy and optimal dose.

Authors:  T Zaglavara; R Haaverstad; B Cumberledge; T Irvine; H Karvounis; G Parharidis; G Louridas; A Kenny
Journal:  Heart       Date:  2002-04       Impact factor: 5.994

8.  Detection of myocardial viability by dobutamine stress echocardiography: incremental value of diastolic wall thickness measurement.

Authors:  T Zaglavara; T Pillay; H Karvounis; R Haaverstad; G Parharidis; G Louridas; A Kenny
Journal:  Heart       Date:  2005-05       Impact factor: 5.994

9.  Comparison of intraoperative transit-time flow measurement with early postoperative magnetic resonance flow mapping in off-pump coronary artery surgery.

Authors:  Ilhan Sanisoglu; Mustafa Guden; Cem Balci; Ertan Sagbas; Cihan Duran; Belhhan Akpinar
Journal:  Tex Heart Inst J       Date:  2003

10.  Transit time flowmetry in coronary surgery--an important tool in graft verification.

Authors:  Emir Mujanović; Emir Kabil; Jacob Bergsland
Journal:  Bosn J Basic Med Sci       Date:  2007-08       Impact factor: 3.363

View more