Literature DB >> 17848157

Transit time flowmetry in coronary surgery--an important tool in graft verification.

Emir Mujanović1, Emir Kabil, Jacob Bergsland.   

Abstract

The aim of this study was to analyze the Transit time flow measurement (TTFM) experience in the first 1000 CABG operations. First 1000 patients had coronary artery bypass grafting (CABG) performed in Cardiovascular Clinic, University Clinical Centre Tuzla, Bosnia and Herzegovina, between September, 1998 and September, 2003. CABG without use of cardiopulmonary bypass (CPB)-(OPCAB) was used as the preferential surgical method both because this method is reported to have equal or better results than CABG with use of CPB (ONCAB), and because of the significant cost savings realized. TTFM was routinely used in all grafts as a quality assurance measure. Criteria for a poor functioning graft were: low mean flow (MF), pulsatility index (PI) above 5 and a poor diastolic flow pattern. When no reversible cause of poor TTFM results were identified the graft was revised. A total of 1394 grafts in OPCAB group and 1478 in ONCAB group were performed. A total of 38 grafts (2,72%) in 37 patients (7,07%) were revised in OPCAB group, and 26 grafts (1,75%) in 26 patients (5,45%) in ONCAB group. 1 patient in OPCAB group needed 2 graft revisions. Graft revisions were more common in OPCAB, but with no significant difference (p=0,1035). The most frequently revised graft was LAD graft in both groups. Although the percentage of grafts revised are relatively low, it is still very important to record TTFM. More than 5% of patients in both groups needed graft revision. Although TTFM does not guarantee that grafts will stay open for a prolonged period of time we certainly believe that grafts that are occluded at the time of surgery will continue to stay occluded. TTFM is especially critical in OPCAB surgery where the technical challenge of grafting is higher then in ONCAB.

Entities:  

Mesh:

Year:  2007        PMID: 17848157      PMCID: PMC5736123          DOI: 10.17305/bjbms.2007.3059

Source DB:  PubMed          Journal:  Bosn J Basic Med Sci        ISSN: 1512-8601            Impact factor:   3.363


  7 in total

1.  Coronary artery bypass grafting (CABG) without cardiopulmonary bypass (CPB): a strategy for improving results in surgical revascularization.

Authors:  J Bergsland; S Schmid; J Yanulevich; S Hasnain; T Z Lajos; T A Salerno
Journal:  Heart Surg Forum       Date:  1998       Impact factor: 0.676

2.  A review of transit-time flow measurement for assessing graft patency.

Authors:  D J VanHimbergen; S C Koenig; S F Jaber; P B Cerrito; P A Spence
Journal:  Heart Surg Forum       Date:  1999       Impact factor: 0.676

Review 3.  Technical tips and pitfalls in OPCAB surgery: the buffalo experience.

Authors:  J Bergsland; G D'Ancona; H Karamanoukian; M Ricci; S Schmid; T A Salerno
Journal:  Heart Surg Forum       Date:  2000       Impact factor: 0.676

4.  Flow measurement in coronary surgery.

Authors:  G D'Ancona; H L Karamanoukian; T A Salerno; S Schmid; J Bergsland
Journal:  Heart Surg Forum       Date:  1999       Impact factor: 0.676

5.  Transit-time flow measurement for detection of early graft failure during myocardial revascularization.

Authors:  B H Walpoth; A Bosshard; I Genyk; B Kipfer; P A Berdat; O M Hess; U Althaus; T P Carrel
Journal:  Ann Thorac Surg       Date:  1998-09       Impact factor: 4.330

6.  Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG.

Authors:  S F Jaber; S C Koenig; B BhaskerRao; D J VanHimbergen; P B Cerrito; D J Ewert; L A Gray; P A Spence
Journal:  Ann Thorac Surg       Date:  1998-09       Impact factor: 4.330

7.  Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting.

Authors:  G D'Ancona; H L Karamanoukian; M Ricci; S Schmid; J Bergsland; T A Salerno
Journal:  Eur J Cardiothorac Surg       Date:  2000-03       Impact factor: 4.191

  7 in total
  1 in total

1.  Improving coronary artery bypass grafting: a systematic review and meta-analysis on the impact of adopting transit-time flow measurement.

Authors:  Daniel J F M Thuijs; Margreet W A Bekker; David P Taggart; A Pieter Kappetein; Teresa M Kieser; Daniel Wendt; Gabriele Di Giammarco; Gregory D Trachiotis; John D Puskas; Stuart J Head
Journal:  Eur J Cardiothorac Surg       Date:  2019-10-01       Impact factor: 4.191

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.