Literature DB >> 9763327

The mucosal attachment at different abutments. An experimental study in dogs.

I Abrahamsson1, T Berglundh, P O Glantz, J Lindhe.   

Abstract

The present experiment was performed to examine if the material used in the abutment part of an implant system influenced the quality of the mucosal barrier that formed following implant installation. 5 beagle dogs were included in the study. The mandibular premolars and the 1st, 2nd and 3rd maxillary premolars were extracted. Three fixtures of the Brånemark System were installed in each mandibular quadrant (a total of 6 fixtures per animal). Abutment connection was performed after 3 months of healing. In each dog the following types of abutments were used: 2 "control abutments" (c.p. titanium), 2 "ceramic abutments" (highly sintered Al2O3), 1 "gold abutment", and 1 "short titanium abutment". This "short titanium abutment" was provided with an outer structure made of dental porcelain fused to gold. Following abutment connection a plaque control program was initiated and maintained for 6 months. The animals were sacrificed and perfused with a fixative. The mandibles were removed and each implant region was dissected, demineralized in EDTA and embedded in EPON. Semithin sections representing the mesial, distal, buccal and lingual aspects of the peri-implant tissues were produced and subjected to histological examination. The findings from the analysis demonstrated that the material used in the abutment portion of the implant influenced the location and the quality of the attachment that occurred between the periimplant mucosa and the implant. Abutments made of c.p. titanium or ceramic allowed the formation of a mucosal attachment which included one epithelial and one connective tissue portion that were about 2 mm and 1-1.5 mm high, respectively. At sites where abutments made of gold alloy or dental porcelain were used, no proper attachment formed at the abutment level, but the soft tissue margin receded and bone resorption occurred. The abutment fixture junction was hereby occasionally exposed and the mucosal barrier became established to the fixture portion of the implant. It was suggested that the observed differences were the result of varying adhesive properties of the materials studied or by variations in their resistance to corrosion.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9763327     DOI: 10.1111/j.1600-051x.1998.tb02513.x

Source DB:  PubMed          Journal:  J Clin Periodontol        ISSN: 0303-6979            Impact factor:   8.728


  41 in total

1.  On the surface elemental composition of non-corroded and corroded dental ceramic materials in vitro.

Authors:  P Milleding; S Karlsson; L Nyborg
Journal:  J Mater Sci Mater Med       Date:  2003-06       Impact factor: 3.896

2.  Effects of hydrophilicity and microtopography of titanium implant surfaces on initial supragingival plaque biofilm formation. A pilot study.

Authors:  F Schwarz; A Sculean; M Wieland; N Horn; E Nuesry; C Bube; J Becker
Journal:  Mund Kiefer Gesichtschir       Date:  2007-12

3.  Fracture behavior of straight or angulated zirconia implant abutments supporting anterior single crowns.

Authors:  Frank P Nothdurft; Klaus E Doppler; Kurt J Erdelt; Andreas W Knauber; Peter R Pospiech
Journal:  Clin Oral Investig       Date:  2010-01-19       Impact factor: 3.573

4.  Histological findings of failed gold micro shunts in primary open-angle glaucoma.

Authors:  Luca Agnifili; Ciro Costagliola; Michele Figus; Giovanna Iezzi; Adriano Piattelli; Paolo Carpineto; Rodolfo Mastropasqua; Marco Nardi; Leonardo Mastropasqua
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-23       Impact factor: 3.117

5.  Comparative assessment of the interfacial soft and hard tissues investing implants and natural teeth in the macaque mandible.

Authors:  Chong Huat Siar; Chooi Gait Toh; Georgios E Romanos; Kok Han Ng
Journal:  Clin Oral Investig       Date:  2014-11-21       Impact factor: 3.573

6.  Fracture behavior of zirconia implant abutments is influenced by superstructure-geometry.

Authors:  Frank P Nothdurft; Konrad Neumann; Andreas W Knauber
Journal:  Clin Oral Investig       Date:  2013-09-20       Impact factor: 3.573

7.  Effect of different abutment materials (zirconia or titanium) on the crestal bone height in 1 year.

Authors:  Vinayak Bharate; Yogesh Kumar; Dheeraj Koli; Gunjan Pruthi; Veena Jain
Journal:  J Oral Biol Craniofac Res       Date:  2019-10-24

8.  A new method using insert-based systems (IBS) to improve cell behavior study on flexible and rigid biomaterials.

Authors:  Charlotte Grenade; Nicolas Moniotte; Eric Rompen; Alain Vanheusden; Amélie Mainjot; Marie-Claire De Pauw-Gillet
Journal:  Cytotechnology       Date:  2016-03-25       Impact factor: 2.058

9.  Bio-inspired stable antimicrobial peptide coatings for dental applications.

Authors:  Kyle V Holmberg; Mahsa Abdolhosseini; Yuping Li; Xi Chen; Sven-Ulrik Gorr; Conrado Aparicio
Journal:  Acta Biomater       Date:  2013-06-19       Impact factor: 8.947

10.  Wound models for periodontal and bone regeneration: the role of biologic research.

Authors:  Anton Sculean; Iain L C Chapple; William V Giannobile
Journal:  Periodontol 2000       Date:  2015-06       Impact factor: 7.589

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.