Literature DB >> 9728307

Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw--a randomised prospective trial.

S R Park1, J S Kang, H S Kim, W H Lee, Y H Kim.   

Abstract

The Gamma AP (Asia-Pacific) locking nail (GAPN) is a modification of the standard Gamma locking nail made especially for use in Oriental patients. We made a randomised prospective comparison of the compression hip screw (CHS) and the Gamma AP locking nail for the internal fixation of 60 intertrochanteric fractures of the hip in elderly patients by comparing perioperative details and analysing the radiographic and clinical results. The operation time for the GAPN group was shorter than for the CHS group and the intraoperative blood loss was lower. The Gamma AP nail enabled earlier mobilisation. We found no significant difference in the time to union and the length of sliding of the lag screw between the two groups. The decrease in the neck shaft angle in the Gamma nail group was significantly smaller than in the CHS patients. There were no significant mechanical complications, such as fracture of the femoral shaft or failure of fixation in the Gamma nail group. On the basis of our observations we conclude that the Gamma AP locking nail is more efficient than the CHS in the treatment of intertrochanteric fractures in geriatric patients.

Entities:  

Mesh:

Year:  1998        PMID: 9728307      PMCID: PMC3619600          DOI: 10.1007/s002640050231

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  25 in total

1.  Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices.

Authors:  L Audigé; B Hanson; M F Swiontkowski
Journal:  Int Orthop       Date:  2003-05-07       Impact factor: 3.075

2.  Failure of knee arthroplasty secondary to inadequate technique in cephalomedullary nailing of a subtrochanteric hip fracture.

Authors:  Rhys Gareth Ellis Clement; Richard Burnett
Journal:  BMJ Case Rep       Date:  2012-04-02

3.  The treatment of transtrochanteric fractures of the femur with a minimally invasive technique using an extramedullary implant MINUS System.

Authors:  Rogério Naim Sawaia; William Dias Belangero
Journal:  Int Orthop       Date:  2007-01-12       Impact factor: 3.075

4.  Are short femoral nails superior to the sliding hip screw? A meta-analysis of 24 studies involving 3,279 fractures.

Authors:  Henry Wynn Jones; Philip Johnston; Martyn Parker
Journal:  Int Orthop       Date:  2006-02-22       Impact factor: 3.075

5.  A meta-analysis of the Gamma nail and dynamic hip screw in treating peritrochanteric fractures.

Authors:  Ming Liu; Zhiming Yang; Fuxing Pei; Fuguo Huang; Shiqiang Chen; Zhou Xiang
Journal:  Int Orthop       Date:  2009-04-29       Impact factor: 3.075

6.  Cephalomedullary nail versus sliding hip screw for fixation of AO 31 A1/2 intertrochanteric femoral fracture: a 12-year comparison of failure, complications, and mortality.

Authors:  Casey S Whale; D Andrew Hulet; Michael J Beebe; David L Rothberg; Chong Zhang; Angela P Presson; Ami R Stuart; Erik N Kubiak
Journal:  Curr Orthop Pract       Date:  2016 Nov-Dec

7.  3066 consecutive Gamma Nails. 12 years experience at a single centre.

Authors:  Alicja J Bojan; Claudia Beimel; Andreas Speitling; Gilbert Taglang; Carl Ekholm; Anders Jönsson
Journal:  BMC Musculoskelet Disord       Date:  2010-06-26       Impact factor: 2.362

8.  Tip-apex distance of intramedullary devices as a predictor of cut-out failure in the treatment of peritrochanteric elderly hip fractures.

Authors:  Jeffrey A Geller; Comron Saifi; Todd A Morrison; William Macaulay
Journal:  Int Orthop       Date:  2009-07-18       Impact factor: 3.075

9.  Effect of varus and valgus alignment on implant loading after proximal femur fracture fixation.

Authors:  Meir Marmor; Kate Liddle; Jenni Buckley; Amir Matityahu
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-04-27

10.  Unstable subtrochanteric fractures--gamma nail versus dynamic condylar screw.

Authors:  Andrés J Pakuts
Journal:  Int Orthop       Date:  2003-08-26       Impact factor: 3.075