Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: a multicenter study. European Microny Study Group.

M Clarke1, B Liu, H Schüller, L Binner, C Kennergren, M Guerola, P Weinmann, O J Ohm.   

Abstract

Pacing threshold is affected by many factors. A pacing system able to confirm capture at each beat and automatically adjust its output close to the actual pacing threshold is highly desirable. This study evaluates the safety and efficacy of the Autocapture function of the Pacesetter Microny SR+. One hundred thirteen patients were recruited from 16 centers in 7 European countries and followed up for 1 year. All pacemakers were implanted with Pacesetter's low polarization, bipolar leads. The key feature of Autocapture is the immediate delivery of a 4.5 V safety backup pulse 62.5 ms after any ineffective ongoing low output pulse. Holter recordings confirmed total reliability of this feature without any exit block. The measured evoked response (ER) signal was stable over time. Acute and chronic pacing thresholds measured by VARIO and Autocapture tests correlated (r > 0.79) over the period of the study. The incidence of backup pulses was 1.1% during pacing. With Autocapture programmed ON, the overall total current consumption was 4.1 microA for VVI and 5.0 microA for VVIR pacing. This study proved that the Autocapture safely and reliably regulates the pacemaker's output according to the prevailing threshold thus providing maximum patient safety and prolonging service life.

Entities:  

Mesh:

Year:  1998        PMID: 9725155     DOI: 10.1111/j.1540-8159.1998.tb00244.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  12 in total

Review 1.  Threshold tracking pacing based on beat by beat evoked response detection: clinical benefits and potential problems.

Authors:  F Duru; U Bauersfeld; H Schüller; R Candinas
Journal:  J Interv Card Electrophysiol       Date:  2000-10       Impact factor: 1.900

Review 2.  Pacing technology: advances in pacing threshold management.

Authors:  Chu-pak Lau; Chung-wah Siu
Journal:  J Zhejiang Univ Sci B       Date:  2010-08       Impact factor: 3.066

3.  Algorithm for ventricular capture verification based on the mechanical evoked response.

Authors:  E Yaacoby; S Akselrod; M Eldar; M Glikson
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

4.  [Not Available].

Authors:  J Sperzel; W Ehrlich; J Carlsson; T Schwarz; A König; Q Zhu; J Neuzner
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2000-01

5.  Uncommon Sense: What Does This Aberrant Pacing Spike Indicate?

Authors:  Daniel J Chu; Stephen Pickett; John Allison; Yochai Birnbaum
Journal:  Tex Heart Inst J       Date:  2020-04-01

6.  Two pacing spikes on the QRS complex in a single-chamber pacemaker.

Authors:  Dinesh Choudhary; Shunmuga Sundaram; Anees Thajudeen; Narayanan Namboodiri
Journal:  Indian Heart J       Date:  2012-09-06

7.  Failure of automatic capture verification in an epicardial pacemaker system.

Authors:  Leonardo Liberman; Allan J Hordof; Daphne S Hsu; Robert H Pass
Journal:  J Interv Card Electrophysiol       Date:  2005-09       Impact factor: 1.900

8.  The influence of mental and physical stress on the autocapture function in children.

Authors:  Tevfik Karagoz; Alpay Celiker
Journal:  J Interv Card Electrophysiol       Date:  2003-08       Impact factor: 1.900

9.  Impact of automatic adjustment of stimulation outputs on pacemaker longevity in a new dual-chamber pacing system.

Authors:  Christiane Brockes; Mariette Rahn-Schönbeck; Firat Duru; Reto Candinas; Marko Turina
Journal:  J Interv Card Electrophysiol       Date:  2003-02       Impact factor: 1.900

10.  Automatic capture verification in pacemakers (autocapture)--utility and problems.

Authors:  Ruth Kam
Journal:  Indian Pacing Electrophysiol J       Date:  2004-04-01