Algorithm for ventricular capture verification based on the mechanical evoked response.

E Yaacoby1, S Akselrod, M Eldar, M Glikson.   

Abstract

Automatic pacemaker capture verification is important for maintaining safety and low energy consumption in pacemaker patients. A new algorithm was developed, based on impedance measurement between pacing electrode poles, which reflects the distribution of the conducting medium between the poles and changes with effective contraction. Data acquired during pacemaker implant in 17 subjects were analysed, with intracardiac impedance recorded while pacing was performed in the ventricle at varying energies, resulting in multiple-captured and non-captured beats. The impedance signals of all captured/non-captured beats were analysed using three different algorithms, based on the morphology of the impedance signal. The algorithm decision for each beat was compared with an actual capture or non-capture, as determined from the simultaneous recording of surface ECG. Two of the three algorithms (Z1 and Zn) were based on impedance values, and one (Z'n) was based on the first derivative of the impedance. Z1 was based on a single sample, whereas Z'n and Z'n were based on several samples in each beat. The total accuracy for each was Z1: 43%, Zn: 87%, Z'n: 92%. It was concluded that impedance-based capture verification is feasible, that a multiple rather than single sample approach for signal classification is both feasible and superior, and that first derivative analysis with multiple samples (Z'n) provides the best results.

Entities:  

Mesh:

Year:  2005        PMID: 16255434     DOI: 10.1007/bf02344733

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  15 in total

1.  Intracardiac impedance plethysmography.

Authors:  R F RUSHMER; D K CRYSTAL; C WAGNER; R M ELLIS
Journal:  Am J Physiol       Date:  1953-07

2.  Feasibility of using intracardiac impedance measurements for capture detection.

Authors:  E Alt; C Kriegler; P Fotuhi; R Willhaus; W Combs; M Heinz; D Hayes
Journal:  Pacing Clin Electrophysiol       Date:  1992-11       Impact factor: 1.976

3.  Feasibility of measuring relative right ventricular volumes and ejection fraction with implantable rhythm control devices.

Authors:  R Chirife; D F Ortega; A I Salazar
Journal:  Pacing Clin Electrophysiol       Date:  1993-08       Impact factor: 1.976

4.  Measurement of ventricular volume by intracardiac impedance: theoretical and empirical approaches.

Authors:  R W Salo; T G Wallner; B D Pederson
Journal:  IEEE Trans Biomed Eng       Date:  1986-02       Impact factor: 4.538

5.  Continuous measurement of ventricular stroke volume by electrical impedance.

Authors:  L A Geddes; H E Hoff; A Mello; C Palmer
Journal:  Cardiovasc Res Cent Bull       Date:  1966 Apr-Jun

6.  Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: a multicenter study. European Microny Study Group.

Authors:  M Clarke; B Liu; H Schüller; L Binner; C Kennergren; M Guerola; P Weinmann; O J Ohm
Journal:  Pacing Clin Electrophysiol       Date:  1998-08       Impact factor: 1.976

7.  Clinical experience with an automatic threshold tracking algorithm study.

Authors:  Charles Kennergren; Berit Larsson; Asa Uhrenius; Fredrik Gadler
Journal:  Pacing Clin Electrophysiol       Date:  2003-12       Impact factor: 1.976

8.  Instantaneous measurement of left and right ventricular stroke volume and pressure-volume relationships with an impedance catheter.

Authors:  R G McKay; J R Spears; J M Aroesty; D S Baim; H D Royal; G V Heller; W Lincoln; R W Salo; E Braunwald; W Grossman
Journal:  Circulation       Date:  1984-04       Impact factor: 29.690

9.  A new pacemaker algorithm for continuous capture verification and automatic threshold determination: elimination of pacemaker afterpotential utilizing a triphasic charge balancing system.

Authors:  G K Feld; C J Love; J Camerlo; R Marsella
Journal:  Pacing Clin Electrophysiol       Date:  1992-02       Impact factor: 1.976

10.  Continuous ventricular volume assessment for diagnosis and pacemaker control.

Authors:  R W Salo; B D Pederson; A L Olive; W C Lincoln; T G Wallner
Journal:  Pacing Clin Electrophysiol       Date:  1984-11       Impact factor: 1.976

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.