Literature DB >> 9722850

Mammography of a phantom and breast tissue with synchrotron radiation and a linear-array silicon detector.

F Arfelli1, V Bonvicini, A Bravin, G Cantatore, E Castelli, L Dalla Palma, M Di Michiel, R Longo, A Olivo, S Pani, D Pontoni, P Poropat, M Prest, A Rashevsky, G Tromba, A Vacchi.   

Abstract

A linear-array, silicon pixel detector, capable of counting single photons, was applied to mammography by using a synchrotron radiation beam. Images were obtained of both a mammographic phantom and a breast-tissue sample. The phantom image was acquired with a mean glandular dose of 0.32 mGy. This detector combined with a synchrotron radiation beam allows acquisition of high-contrast, low-dose images of soft tissues.

Mesh:

Substances:

Year:  1998        PMID: 9722850     DOI: 10.1148/radiology.208.3.9722850

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Multimodal hard X-ray imaging of a mammography phantom at a compact synchrotron light source.

Authors:  Simone Schleede; Martin Bech; Klaus Achterhold; Guillaume Potdevin; Martin Gifford; Rod Loewen; Cecile Limborg; Ronald Ruth; Franz Pfeiffer
Journal:  J Synchrotron Radiat       Date:  2012-05-10       Impact factor: 2.616

2.  Innovative radiographic system to improve the sharpness of radiographs: could a phase-shift effect contribute to improved image-quality for plain computed radiographs for general use?

Authors:  Junji Tanaka; Hiromi Oda; Toshihide Mimura; Chika Honda; Hiromu Oohara; Hiroaki Kawasaki; Atsushi Kondo; Yukihito Wada
Journal:  Jpn J Radiol       Date:  2010-01-30       Impact factor: 2.374

3.  Radiologic-pathological correlation of punctate hyperechoic foci by ultrasound in stereotactic vacuum-assisted breast biopsy samples.

Authors:  Hiroko Okazaki; Fumio Tsujimoto; Ichirou Maeda; Tomoyuki Ohta; Yoshihide Kanemaki; Kyoko Okamoto; Hiroshi Shimamoto; Yukari Yabuki; Haruki Ogata; Tomohiko Ohta; Mamoru Fukuda; Yasuo Nakajima
Journal:  Jpn J Radiol       Date:  2009-12-25       Impact factor: 2.374

4.  A phase sensitive x-ray breast tomosynthesis system: Preliminary patient images with cancer lesions.

Authors:  Muhammad U Ghani; Laurie L Fajardo; Farid Omoumi; Aimin Yan; Peter Jenkins; Molly Wong; Yuhua Li; Michael E Peterson; Edward J Callahan; Stephen L Hillis; Bin Zheng; Xizeng Wu; Hong Liu
Journal:  Phys Med Biol       Date:  2021-10-29       Impact factor: 3.609

5.  Visualising liver fibrosis by phase-contrast X-ray imaging in common bile duct ligated mice.

Authors:  Xi Zhang; Xin-Rong Yang; Yu Chen; Hai-Qing Li; Rui-Min Li; Qing-Xi Yuan; Pei-Ping Zhu; Wan-Xia Huang; Wei-Jun Peng
Journal:  Eur Radiol       Date:  2012-08-19       Impact factor: 5.315

  5 in total