Literature DB >> 9688034

Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses.

G Rankin1, M Stokes.   

Abstract

OBJECTIVE: To provide a practical guide to appropriate statistical analysis of a reliability study using real-time ultrasound for measuring muscle size as an example.
DESIGN: Inter-rater and intra-rater (between-scans and between-days) reliability.
SUBJECTS: Ten normal subjects (five male) aged 22-58 years.
METHOD: The cross-sectional area (CSA) of the anterior tibial muscle group was measured using real-time ultrasonography. MAIN OUTCOME MEASURES: Intraclass correlation coefficients (ICCs) and the 95% confidence interval (CI) for the ICCs, and Bland and Altman method for assessing agreement, which includes calculation of the mean difference between measures (d), the 95% CI for d, the standard deviation of the differences (SDdiff), the 95% limits of agreement and a reliability coefficient.
RESULTS: Inter-rater reliability was high, ICC (3,1) was 0.92 with a 95% CI of 0.72 --> 0.98. There was reasonable agreement between measures on the Bland and Altman test, as d was -0.63 cm2, the 95% CI for d was -1.4 --> 0.14 cm2, the SDdiff was 1.08 cm2, the 95% limits of agreement -2.73 --> 1.53 cm2 and the reliability coefficient was 2.4. Between-scans repeatability was high, ICCs (1,1) were 0.94 and 0.93 with 95% CIs of 0.8 --> 0.99 and 0.75 --> 0.98, for days 1 and 2 respectively. Measures showed good agreement on the Bland and Altman test: d for day 1 was 0.15 cm2 and for day 2 it was -0.32 cm2, the 95% CIs for d were -0.51 --> 0.81 cm2 for day 1 and -0.98 --> 0.34 cm2 for day 2; SDdiff was 0.93 cm2 for both days, the 95% imits of agreement were -1.71 --> 2.01 cm2 for day 1 and -2.18 --> 1.54 cm2 for day 2; the reliability coefficient was 1.80 for day 1 and 1.88 for day 2. The between-days ICC (1,2) was 0.92 and the 95% CI 0.69 --> 0.98. The d was -0.98 cm2, the SDdiff was 1.25 cm2 with 95% limits of agreement of -3.48 --> 1.52 cm2 and the reliability coefficient 2.8. The 95% CI for d (-1.88 --> -0.08 cm2) and the distribution graph showed a bias towards a larger measurement on day 2.
CONCLUSIONS: The ICC and Bland and Altman tests are appropriate for analysis of reliability studies of similar design to that described, but neither test alone provides sufficient information and it is recommended that both are used.

Mesh:

Year:  1998        PMID: 9688034     DOI: 10.1191/026921598672178340

Source DB:  PubMed          Journal:  Clin Rehabil        ISSN: 0269-2155            Impact factor:   3.477


  171 in total

1.  Ultrasonographic assessment of human skeletal muscle size.

Authors:  Neil D Reeves; Constantinos N Maganaris; Marco V Narici
Journal:  Eur J Appl Physiol       Date:  2003-11-25       Impact factor: 3.078

2.  Evaluation of the reliability of two field hockey specific sprint and dribble tests in young field hockey players.

Authors:  K A P M Lemmink; M T Elferink-Gemser; C Visscher
Journal:  Br J Sports Med       Date:  2004-04       Impact factor: 13.800

3.  Response of thermocouples interfaced to electrothermometers when immersed in 5 water bath temperatures.

Authors:  Blaine C Long; Lisa S Jutte; Kenneth L Knight
Journal:  J Athl Train       Date:  2010 Jul-Aug       Impact factor: 2.860

4.  Letter to the Editor concerning "The validity and reliability of "Spinal Mouse" assessment of spinal curvatures in the frontal plane in pediatric adolescent idiopathic thoraco-lumbar curves" by Livanelioglu A, Kaya F, Nabiyev V, Demirkiran G, Fırat T (2015) Eur Spine J Apr 22 [Epub ahead of print].

Authors:  Johnny Padulo; Nicola Luigi Bragazzi; Salvatore Motta; Luca P Ardigò
Journal:  Eur Spine J       Date:  2015-08-11       Impact factor: 3.134

5.  Answer to the Letter to the Editor of L. P. Ardigò et al. concerning "The validity and reliability of "Spinal Mouse" assessment of spinal curvatures in the frontal plane in pediatric adolescent idiopathic thoracolumbar curves" by Livanelioglu A, Kaya F, Nabiyev V, Demirkiran G, Fırat T (2015) Eur Spine J Apr 22 [Epub ahead of print].

Authors:  Ayse Livanelioglu
Journal:  Eur Spine J       Date:  2015-08-13       Impact factor: 3.134

6.  Test-retest reliability of HeartQoL and its comparability to the MacNew heart disease health-related quality of life questionnaire.

Authors:  Wan Ling Lee; Karuthan Chinna; Awang Bulgiba; Khatijah Lim Abdullah; Imran Zainal Abidin; Stefan Höfer
Journal:  Qual Life Res       Date:  2015-08-09       Impact factor: 4.147

7.  The validation of a novel activity monitor in the measurement of posture and motion during everyday activities.

Authors:  P M Grant; C G Ryan; W W Tigbe; M H Granat
Journal:  Br J Sports Med       Date:  2006-09-15       Impact factor: 13.800

8.  Muscle thickness changes during abdominal hollowing: an assessment of between-day measurement error in controls and patients with chronic low back pain.

Authors:  Anne F Mannion; Natascha Pulkovski; Deborah Gubler; Mark Gorelick; David O'Riordan; Thanasis Loupas; Peter Schenk; Hans Gerber; Haiko Sprott
Journal:  Eur Spine J       Date:  2008-01-15       Impact factor: 3.134

9.  A home balance exercise program improves walking in people with cerebellar ataxia.

Authors:  Jennifer L Keller; Amy J Bastian
Journal:  Neurorehabil Neural Repair       Date:  2014-02-13       Impact factor: 3.919

10.  The association of nutritional status and gender with cross-sectional area of the multifidus muscle in establishing normative data.

Authors:  Todd Watson; Sue McPherson; Kathy Starr
Journal:  J Man Manip Ther       Date:  2008
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.