Literature DB >> 9674684

A clinical study of space closure with nickel-titanium closed coil springs and an elastic module.

R H Samuels1, S J Rudge, L H Mair.   

Abstract

A previous study has shown that a 150-gram nickel-titanium closed coil spring (Sentalloy, GAC International Inc.) closed spaces more quickly and more consistently than an elastic module (Alastik, Unitec/3M). This study used the same friction sensitive sliding mechanics of pitting the six anterior teeth against the second bicuspid and first molars, to examine the rate of space closure of 100-gram and 200-gram nickel-titanium closed coil springs. The results for the three springs and elastic module were compared. The nickel-titanium closed coil springs produced a more consistent space closure than the elastic module. The 150- and 200-gram springs produced a faster rate of space closure than the elastic module or the 100-gram spring. No significant difference was noted between the rates of closure for the 150- and the 200-gram springs.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9674684     DOI: 10.1016/s0889-5406(98)70241-0

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  21 in total

1.  An indigenously designed apparatus for measuring orthodontic force.

Authors:  S P Saravana Dinesh; A V Arun; K K Shantha Sundari; Christine Samantha; K Ambika
Journal:  J Clin Diagn Res       Date:  2013-10-24

2.  Mass retraction movement of the anterior upper teeth using orthodontic mini-implants as anchorage.

Authors:  Leonardo Henrique de Lima Araújo; Elton Gonçalves Zenóbio; Wellington Pacheco; Maurício Greco Cosso; Flávio Ricardo Manzi; Jamil Awad Shibli
Journal:  Oral Maxillofac Surg       Date:  2011-01-28

3.  Comparing patient-centered outcomes and efficiency of space closure between nickel-titanium closed-coil springs and elastomeric power chains during orthodontic treatment.

Authors:  Serene A Badran; Juman M Al-Zaben; Lina M Al-Taie; Haya Tbeishi; Mahmoud K Al-Omiri
Journal:  Angle Orthod       Date:  2022-07-01       Impact factor: 2.684

4.  In-vivo force decay of nickel-titanium closed-coil springs.

Authors:  Crystal Cox; Tung Nguyen; Lorne Koroluk; Ching-Chang Ko
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-04       Impact factor: 2.650

5.  Combined Use of Retraction and Torque Arch with Mini-Screws: A Cephalometric Study.

Authors:  Mihri Amasyalı; Fidan Alakuş Sabuncuoğlu; Şeniz Karaçay; Mehmet Doğru; Handan Altuğ
Journal:  Turk J Orthod       Date:  2017-01-11

6.  Forces of various nickel titanium closed coil springs.

Authors:  Anthony Louis Maganzini; Alan M Wong; Mairaj K Ahmed
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

7.  Effect of micro-osteoperforations on rate of space closure by mini-implant supported maxillary anterior en-masse retraction: A randomized clinical trial.

Authors:  Pradeep Raghav; Amit Kumar Khera; Pranav Bhasin
Journal:  J Oral Biol Craniofac Res       Date:  2021-01-22

8.  Open-coil retraction spring.

Authors:  Pavankumar Janardan Vibhute
Journal:  Case Rep Dent       Date:  2011-09-29

9.  Crevicular Alkaline Phosphatase Activity and Rate of Tooth Movement of Female Orthodontic Subjects under Different Continuous Force Applications.

Authors:  Rohaya Megat Abdul Wahab; Maryati Md Dasor; Sahidan Senafi; Asma Alhusna Abang Abdullah; Zulham Yamamoto; Abdul Aziz Jemain; Shahrul Hisham Zainal Ariffin
Journal:  Int J Dent       Date:  2013-05-02

10.  Force-degradation pattern of six different orthodontic elastomeric chains.

Authors:  Ah Mirhashemi; A Saffarshahroudi; A Sodagar; M Atai
Journal:  J Dent (Tehran)       Date:  2012-12-31
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.