Literature DB >> 35348615

Comparing patient-centered outcomes and efficiency of space closure between nickel-titanium closed-coil springs and elastomeric power chains during orthodontic treatment.

Serene A Badran, Juman M Al-Zaben, Lina M Al-Taie, Haya Tbeishi, Mahmoud K Al-Omiri.   

Abstract

OBJECTIVES: To compare patient-reported pain, discomfort, and difficulty in maintaining proper brushing between nickel-titanium closed-coil springs (CS) and elastomeric power chains (PC) when used for space closure. The secondary aims were to compare plaque control and efficiency of space closure between these two force delivery systems.
MATERIALS AND METHODS: A total of 48 patients who required extractions of upper first premolars and distal movement of upper canines had the CS randomly allocated to either the right or left side. Blinding was applied at data collection and analysis. Primary outcomes were pain intensity measured on visual analog scale, pain onset and duration, discomfort, and difficulty in maintaining proper brushing from the start of canine retraction at baseline and at 6 and 12 weeks thereafter. Secondary outcomes were plaque scores and the rate of space closure.
RESULTS: No significant differences in mean pain scores, pain onset, and duration at different time intervals between CS and PC were observed. The CS side was significantly less comfortable than the PC (P < .0001) and more difficult to keep clean (P = .008). No significant differences in plaque scores were observed between CS and PC groups at any time interval. CS produced a faster rate of space closure than did PC (P = .008).
CONCLUSIONS: CS were less tolerated than PC by patients but produced an average of 0.5 mm more movement than did the PC during the 12-week study period.
© 2022 by The EH Angle Education and Research Foundation, Inc.

Entities:  

Keywords:  Canine retraction; Elastomeric power chain; Ni-Ti coil springs; Patient-centered outcomes; Plaque scores

Mesh:

Substances:

Year:  2022        PMID: 35348615      PMCID: PMC9235384          DOI: 10.2319/120721-906

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.684


  21 in total

1.  PERIODONTAL DISEASE IN PREGNANCY. II. CORRELATION BETWEEN ORAL HYGIENE AND PERIODONTAL CONDTION.

Authors:  J SILNESS; H LOE
Journal:  Acta Odontol Scand       Date:  1964-02       Impact factor: 2.331

Review 2.  Intraoral aging of orthodontic materials: the picture we miss and its clinical relevance.

Authors:  Theodore Eliades; Christoph Bourauel
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-04       Impact factor: 2.650

3.  A clinical comparison between nickel titanium springs and elastomeric chains.

Authors:  Jim Bokas; Michael Woods
Journal:  Aust Orthod J       Date:  2006-05

4.  Efficacy of elastic memory chains versus nickel-titanium coil springs in canine retraction: A two-center split-mouth randomized clinical trial.

Authors:  Mashallah Khanemasjedi; Mehrnaz Moradinejad; Pedram Javidi; Ozra Niknam; Nima Haghighat Jahromi; Vahid Rakhshan
Journal:  Int Orthod       Date:  2017-11-16

Review 5.  Effectiveness of nickel-titanium springs vs elastomeric chains in orthodontic space closure: A systematic review and meta-analysis.

Authors:  H Mohammed; M Z Rizk; K Wafaie; M Almuzian
Journal:  Orthod Craniofac Res       Date:  2017-12-19       Impact factor: 1.826

6.  Force decay of elastomeric chain--a serial study. Part II.

Authors:  T C Lu; W N Wang; T H Tarng; J W Chen
Journal:  Am J Orthod Dentofacial Orthop       Date:  1993-10       Impact factor: 2.650

7.  A randomized clinical trial to compare three methods of orthodontic space closure.

Authors:  V Dixon; M J F Read; K D O'Brien; H V Worthington; N A Mandall
Journal:  J Orthod       Date:  2002-03

8.  A clinical investigation of force delivery systems for orthodontic space closure.

Authors:  C Nightingale; S P Jones
Journal:  J Orthod       Date:  2003-09

9.  In-vivo force decay of nickel-titanium closed-coil springs.

Authors:  Crystal Cox; Tung Nguyen; Lorne Koroluk; Ching-Chang Ko
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-04       Impact factor: 2.650

10.  Pain and discomfort associated with orthodontic separator placement in patients attending the Lagos University Teaching Hospital, Lagos, Nigeria.

Authors:  I L Utomi; O O Odukoya
Journal:  Odontostomatol Trop       Date:  2013-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.