| Literature DB >> 23323182 |
Ah Mirhashemi1, A Saffarshahroudi, A Sodagar, M Atai.
Abstract
OBJECTIVE: An ideal orthodontic force system should exert continuous light force. Thus, many efforts have been made to improve the memory characteristics of elastomeric chains. The aim of this study was to compare elastomeric chains (ECs) claimed by their manufacturers to offer high memory with traditional ones according to their force-extension diagrams.Entities:
Keywords: Elastomeric; Orthodontic Appliance Design
Year: 2012 PMID: 23323182 PMCID: PMC3536455
Source DB: PubMed Journal: J Dent (Tehran) ISSN: 1735-2150
Custom made device comprising six rows of 40 pairs of pins which kept the elastomers stretched at the length of 25mm
| C1 | E-chain | 850–235 | American orthodontics | |
| C2 | E-chain | KI-30-01-25 | GAC | |
| C3 | E-chain | 35444 | Ortho Technology | |
| M1 | Memory chain | 854–255 | American orthodontics | |
| M2 | Super elastic chain | KIT-34-012-068 | GAC | |
| M3 | Memory chain | 430–902 | Ortho Technology |
Fig 1Custom made device comprising six rows of 40 pairs of pins which kept the elastomers stretched at the length of 25mm
Mean and Standard Deviation of Force Values (gf) for the Studied Elastomeric Chains After Specific Time Intervals
|
| ||||||
|---|---|---|---|---|---|---|
|
| ||||||
| M(SD) | M(SD) | M(SD) | M(SD) | M(SD) | M(SD) | |
| 683.9(17.2) | 489.3(6.5) | 679.8(10.7) | 436.5(23.5) | 835.3(18.5) | 667.0(26.7) | |
| 549.8(15.3) | 459.2(10.8) | 585.1(16.7) | 418.8(5.8) | 666.3(16.7) | 638.9(16.3) | |
| 533.4(13.6) | 481.5(7.3) | 561.7(23.2) | 419.3(17.2) | 631.8(21.2) | 638.0(22.0) | |
| 504.8(10.9) | 444.1(9.2) | 539.1(15.3) | 382.4(5.1) | 574.9(49.2) | 625.3(46.0) | |
| 491.8(33.6) | 479.7(20.6) | 473.9(42.0) | 409.5(2.7) | 534.1(30.5) | 634.2(40.6) | |
| 488.1(28.6) | 430.3(29.5) | 501.6(7.09) | 380.6(14.2) | 499.7(48.0) | 548.8(7.6) | |
| 367.2(32.7) | 406.8(40.3) | 396.8(23.0) | 404.0(17.8) | 480.3(97.7) | 527.2(57.0) | |
| 271.0(7.6) | 295.5(12.2) | 180.5(31.9) | 279.4(17.0) | 350.6(35.9) | 357.9(19.1) | |
M = Mean; SD = Standard deviation; C= Conventional type; M = Memory type; 1=American orthodontics; 2=GAC; 3=Ortho Technology
Categorization of the Studied Elastomeric Chains Determined by Their Initial Force Value (gf) Based on Tukey’s Test Results
| 436.47 | |||
| 489.34 | |||
| 667.03 | |||
| 679.78 | |||
| 684.00 | |||
| 835.28 | |||
| 0.622 | 0.995 | 1.000 |
Subset for α=0.05
C= Conventional type; M = Memory type; 1=American orthodontics; 2=GAC; 3=Ortho Technology
Mean Difference and Standard Deviation of Force Values (gf) Between Studied Elastomeric Chains After Specific Time Intervals Using the Tukey’s Test
| 4(30.0) | −35.2(8.9) | −28.4(11.5) | −34.3(19.0) | 17.9(19.9) | −13.5(19.2) | −30.0(35.5) | 90.5(17.3) | |
| −151.2(30.0) | −116.5(9.5) | −98.5(11.5) | −70.2(19.0) | −42.2(23.0) | −11.6(18.2) | −113.2(35.5) | −80.0(18.5) | |
| 194.7(33.5) | 90.7(8.9) | 51.9(11.5) | 60.7(20.2) | 12.0(19.9) | 57.8(19.2) | −40.0(35.5) | −24.5(17.3) | |
| 247.5(33.6) | 131.1(8.9) | 114.1(11.5) | 122.4(20.2) | 82.3(19.9) | 107.5(18.2) | −36.9(35.5) | −8.3(17.3) | |
| 17.0(33.5) | −89.1(8.9) | −104.6(12.2) | −120.5(19.0) | −142.4(19.9) | −60.7(18.2) | −160.0(35.5) | −86.9(17.3) | |
| −155.3(30.0) | −81.3(9.5) | −70.1(11.5) | −36.0(19.0) | −60.1(23.0) | 1.8(18.2) | −83.5(33.5) | −170.1 (17.3) | |
| 190.7(33.6) | 126.0(8.9) | 80.2(11.5) | 95.0(20.2) | −5.8(19.9) | 71.3(19.2) | −10.0(33.5) | −114.9(16.0) | |
| 243.5(33.7) | 166.3(8.9) | 142.4(11.5) | 156.7(20.2) | 64.4(19.9) | 121.0(18.2) | −7.2(33.5) | −98.8(16.0) | |
| 13.0(33.5) | −54.0(8.9) | −76.3(12.2) | −86.2(19.0) | −160.3(19.9) | −47.2(18.2) | −130.4(33.5) | −177.4(17.3) | |
| 346.0(33.6) | 207.2(9.5) | 150.3(11.5) | 131.0(20.2) | 54.3(23.0) | 69.5(18.2) | 73.5(33.5) | 55.1(17.3) | |
| 398.8(33.6) | 248.0(9.5) | 212.6(11.5) | 193.0(20.2) | 124.5(23.0) | 119.2(17.2) | 76.3(33.5) | 71.3(17.3) | |
| 168.3(33.6) | 27.4(9.5) | −6.2(12.2) | −50.3(19.0) | −100.2(23.0) | −49.0(17.2) | −46.9(33.5) | −7.3(17.3) | |
| 52.8(36.8) | 40.4(8.9) | 62.2(11.5) | 61.7(21.3) | 70.3(19.9) | 49.7(18.2) | 2.8(33.5) | 16.2(16.0) | |
| −177.7(36.8) | −179.8(8.9) | −156.5(12.2) | −181.2(20.2) | −154.5(19.9) | −118.5(18.2) | −120.4(33.5) | −62.4(16.0) | |
| −230.5(36.8) | −220.2(8.9) | −218.7(12.2) | −242.9(20.2) | −224.7(19.9) | −168.2(17.2) | −123.2(33.5) | −79.0(16.0) |
C= Conventional type; M = Memory type; 1=American orthodontics; 2=GAC; 3=Ortho Technology;
Significance level of 5% (p < 0.05)
Percentages of Force Loss of Initial Forces for Studied Elastomeric Chains in Different Time Intervals
| 19.7 | 13.9 | 20.2 | 4.2 | |||||
| 22.1 | 17.4 | 24.4 | 4.4 | |||||
| 26.2 | 20.7 | 31.2 | 6.3 | |||||
| 28.2 | 30.3 | 36.1 | 4.9 | |||||
| 28.6 | 26.2 | 40.2 | 12.1 | 12.8 | 17.7 | |||
| 46.3 | 41.4 | 42.5 | 16.9 | 7.4 | 21 | |||
| 60.4 | 73.4 | 58.0 | 39.6 | 36.0 | 46.3 |
C= Conventional type; M = Memory type; 1=American orthodontics; 2=GAC; 3=Ortho Technology; MC= mean of conventional types; MM= mean of memory types
Comparison of Initial and Final Force Values for Each Elastomeric Group Based on Tukey’s Test
| 412.94 (15.5) | 499.2 (15.1) | 484.63 (46.9) | 193.8 (14.8) | 157.1 (10.2) | 309.1 (24.3) |
Significance level of 5% (p < 0.05)
Mean (SD) of Percentage of Elongation Required to Deliver 200 g Force in Different Time Intervals
| 23.3(1.7) | 45.8(1.7) | 47.8(1.6) | 45.0(1.0) | 39.9(4.5) | 37.4(2.1) | 39.9(5.2) | 30.2(0.8) | |
| 27.6(3.8) | 43.8(3.5) | 42.6(2.8) | 44.0(3.0) | 39.5(5.3) | 34.4(2.0) | 41.8(3.0) | 33.9(3.3) | |
| 23.9(4.5) | 33.7(4.4) | 38.1(1.5) | 30.7(4.0) | 29.5(3.0) | 29.1(2.4) | 33.0(5.8) | 25.1(1.1) | |
| 31.3(0.5) | 58.0(3.8) | 61.0(3.6) | 59.7(0.8) | 58.4(2.1) | 61.9(5.3) | 57.9(3.4) | 37.2(1.8) | |
| 38.1(3.6) | 52.5(3.7) | 56.9(5.6) | 58.8(3.9) | 56.1(1.6) | 56.2(6.0) | 54.4(4.6) | 38.4(4.0) | |
| 23.6(3.7) | 37.1(2.5) | 48.3(6.1) | 46.5(1.7) | 45.4(0.9) | 46.9(1.3) | 35.1(3.1) | 27.9(0.9) |
Fig 2Force degradation pattern of all studied specimens. C1: Conventional chain of American orthodontics, C2: Conventional chain of GAC, C3: Conventional chain of Ortho Technology, M1: Memory chain of American orthodontics, M2: Super elastic chain of GAC, M3: Extreme chain of Ortho Technology. In horizontal axis time intervals of 1–8 represents 0, 1, 8, 24 and 72 hours and 1, 2 and 4 weeks, respectively