Literature DB >> 9607213

Perfusion quantitation in transplanted rat kidney by MRI with arterial spin labeling.

J J Wang1, K S Hendrich, E K Jackson, S T Ildstad, D S Williams, C Ho.   

Abstract

The purpose of this study was to determine the feasibility of using quantitative magnetic resonance imaging (MRI) with non-invasive arterial spin labeling to assess perfusion of transplanted kidneys in rats. MRI studies were performed on five groups of rats: normal Fisher 344 rats, Fisher 344 rats that had received a syngeneic kidney transplant either 3 or seven days prior to study, and Fisher 344 rats that had received an allogeneic kidney (ACI rat as the donor) either three or seven days prior to study. The contralateral native kidney remained in place for comparison. Cortical perfusion was quantitated from a slice through the center of each kidney in anesthetized rats at 4.7 Tesla with a fast gradient-echo MRI sequence following the arterial spin labeling. The spin-lattice relaxation time was measured within the cortex, and the cross sectional area of the kidney was also determined within the same MRI plane. Immediately after the perfusion imaging measurement, transplanted kidneys were removed and scored for rejection using the Banff histological criteria. Renal cortical perfusion in normal kidneys was 7.5 +/- 0.8 ml/g/min (N = 12 rats, 24 kidneys). At the third day post-transplantation, that is, before marked acute rejection, the renal cortical perfusion rate was similar in both syngeneic and allogeneic kidneys [3.3 +/- 1.7 (N = 6) and 3.0 +/- 2.4 ml/g/min (N = 6), respectively]. In contrast, at the seventh day post-transplantation, that is, during severe rejection, the renal cortical perfusion rate in allogeneic kidneys was very low (undetectable) compared to the value in syngeneic kidneys [that is, < or = 0.3 (N = 6) versus 5.2 +/- 2.0 ml/g/min (N = 6), respectively]. Moreover, the renal cortical perfusion rate determined by MRI was significantly (P < 0.05, r = -0.82) correlated with histological rejection. We conclude that the quantitative measurement of renal cortical perfusion by MRI with arterial spin-labeling could provide a non-invasive diagnostic method for monitoring the status of renal transplants without requiring the administration of a contrast agent.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9607213     DOI: 10.1046/j.1523-1755.1998.00945.x

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  11 in total

1.  Noninvasive measurement of renal blood flow by magnetic resonance imaging in rats.

Authors:  Cesar A Romero; Glauber Cabral; Robert A Knight; Guangliang Ding; Edward L Peterson; Oscar A Carretero
Journal:  Am J Physiol Renal Physiol       Date:  2017-10-04

2.  Comparing kidney perfusion using noncontrast arterial spin labeling MRI and microsphere methods in an interventional swine model.

Authors:  Nathan S Artz; Andrew L Wentland; Elizabeth A Sadowski; Arjang Djamali; Thomas M Grist; Songwon Seo; Sean B Fain
Journal:  Invest Radiol       Date:  2011-02       Impact factor: 6.016

3.  MR elastography in renal transplant patients and correlation with renal allograft biopsy: a feasibility study.

Authors:  Christine U Lee; James F Glockner; Kevin J Glaser; Meng Yin; Jun Chen; Akira Kawashima; Bohyun Kim; Walter K Kremers; Richard L Ehman; James M Gloor
Journal:  Acad Radiol       Date:  2012-04-13       Impact factor: 3.173

4.  Sensitivity of arterial spin labeling perfusion MRI to pharmacologically induced perfusion changes in rat kidneys.

Authors:  Huan Tan; Jon Thacker; Tammy Franklin; Pottumarthi V Prasad
Journal:  J Magn Reson Imaging       Date:  2014-05-06       Impact factor: 4.813

5.  Quantitative characterization of glomerular fibrosis with magnetic resonance imaging: a feasibility study in a rat glomerulonephritis model.

Authors:  Christopher C Conlin; Yufeng Huang; Brian Adam Jamison Gordon; Jeff L Zhang
Journal:  Am J Physiol Renal Physiol       Date:  2018-01-03

6.  Arterial spin labeling MRI for assessment of perfusion in native and transplanted kidneys.

Authors:  Nathan S Artz; Elizabeth A Sadowski; Andrew L Wentland; Thomas M Grist; Songwon Seo; Arjang Djamali; Sean B Fain
Journal:  Magn Reson Imaging       Date:  2010-09-17       Impact factor: 2.546

Review 7.  Functional MRI of the kidney: tools for translational studies of pathophysiology of renal disease.

Authors:  Pottumarthi V Prasad
Journal:  Am J Physiol Renal Physiol       Date:  2006-05

8.  Quantification of renal allograft perfusion using arterial spin labeling MRI: initial results.

Authors:  Rotem S Lanzman; Hans-Jörg Wittsack; Petros Martirosian; Panagiota Zgoura; Philip Bilk; Patric Kröpil; Fritz Schick; Adina Voiculescu; Dirk Blondin
Journal:  Eur Radiol       Date:  2009-12-01       Impact factor: 5.315

9.  Engraftment of syngeneic and allogeneic endothelial cells, hepatocytes and cholangiocytes into partially hepatectomized rats previously treated with mitomycin C.

Authors:  Kate E Brilliant; David R Mills; Helen M Callanan; Douglas C Hixson
Journal:  Transplantation       Date:  2009-08-27       Impact factor: 4.939

10.  Quantitative MR measures of intrarenal perfusion in the assessment of transplanted kidneys: initial experience.

Authors:  Andrew L Wentland; Elizabeth A Sadowski; Arjang Djamali; Thomas M Grist; Bryan N Becker; Sean B Fain
Journal:  Acad Radiol       Date:  2009-06-17       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.