Literature DB >> 23814706

Biologic stability of plasma ion-implanted miniscrews.

Young-Chae Cho1, Jung-Yul Cha, Chung-Ju Hwang, Young-Chel Park, Han-Sung Jung, Hyung-Seog Yu.   

Abstract

OBJECTIVE: To gain basic information regarding the biologic stability of plasma ion-implanted miniscrews and their potential clinical applications.
METHODS: Sixteen plasma ion-implanted and 16 sandblasted and acid-etched (SLA) miniscrews were bilaterally inserted in the mandibles of 4 beagles (2 miniscrews of each type per quadrant). Then, 250 - 300 gm of force from Ni-Ti coil springs was applied for 2 different periods: 12 weeks on one side and 3 weeks contralaterally. Thereafter, the animals were sacrificed and mandibular specimens including the miniscrews were collected. The insertion torque and mobility were compared between the groups. The bone-implant contact and bone volume ratio were calculated within 800 µm of the miniscrews and compared between the loading periods. The number of osteoblasts was also quantified. The measurements were expressed as percentages and analyzed by independent t-tests (p < 0.05).
RESULTS: No significant differences in any of the analyzed parameters were noted between the groups.
CONCLUSIONS: The preliminary findings indicate that plasma ion-implanted miniscrews have similar biologic characteristics to SLA miniscrews in terms of insertion torque, mobility, bone-implant contact rate, and bone volume rate.

Entities:  

Keywords:  Histology; Orthodontic mini-implant; Stability; Surface treatment

Year:  2013        PMID: 23814706      PMCID: PMC3694203          DOI: 10.4041/kjod.2013.43.3.120

Source DB:  PubMed          Journal:  Korean J Orthod            Impact factor:   1.372


  13 in total

1.  Intrusion of posterior teeth using mini-screw implants.

Authors:  Young-Chel Park; Seung-Yeon Lee; Doo-Hyung Kim; Sung-Hoon Jee
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-06       Impact factor: 2.650

2.  A prospective study of the risk factors associated with failure of mini-implants used for orthodontic anchorage.

Authors:  Shih-Jung Cheng; I-Yun Tseng; Jang-Jaer Lee; Sang-Heng Kok
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Jan-Feb       Impact factor: 2.804

3.  Load-related implant reaction of mini-implants used for orthodontic anchorage.

Authors:  André Büchter; Dirk Wiechmann; Stefan Koerdt; Hans Peter Wiesmann; Josef Piffko; Ulrich Meyer
Journal:  Clin Oral Implants Res       Date:  2005-08       Impact factor: 5.977

4.  The use of microimplants in orthodontic anchorage.

Authors:  Chung-Ho Chen; Chao-San Chang; Chi-Hsin Hsieh; Yu-Chuan Tseng; Yee-Shyong Shen; I-Yueh Huang; Chia-Fu Yang; Chun-Ming Chen
Journal:  J Oral Maxillofac Surg       Date:  2006-08       Impact factor: 1.895

5.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.

Authors:  D Buser; R K Schenk; S Steinemann; J P Fiorellini; C H Fox; H Stich
Journal:  J Biomed Mater Res       Date:  1991-07

6.  Preparation of bioactive Ti and its alloys via simple chemical surface treatment.

Authors:  H M Kim; F Miyaji; T Kokubo; T Nakamura
Journal:  J Biomed Mater Res       Date:  1996-11

7.  Quantitative and qualitative investigations of surface enlarged titanium and titanium alloy implants.

Authors:  C H Han; C B Johansson; A Wennerberg; T Albrektsson
Journal:  Clin Oral Implants Res       Date:  1998-02       Impact factor: 5.977

8.  Pull-out strength of monocortical screws placed in the maxillae and mandibles of dogs.

Authors:  Sarandeep S Huja; Alan S Litsky; F Mike Beck; Kenneth A Johnson; Peter E Larsen
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-03       Impact factor: 2.650

9.  Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides.

Authors:  Young-Taeg Sul; Carina B Johansson; Youngsoo Jeong; Ann Wennerberg; Tomas Albrektsson
Journal:  Clin Oral Implants Res       Date:  2002-06       Impact factor: 5.977

10.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981
View more
  6 in total

1.  Modified titanium implant as a gateway to the human body: the implant mediated drug delivery system.

Authors:  Young-Seok Park; Joo-Youn Cho; Shin-Jae Lee; Chee Il Hwang
Journal:  Biomed Res Int       Date:  2014-07-22       Impact factor: 3.411

2.  Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles.

Authors:  Sung-Hwan Choi; Seong-Jin Kim; Kee-Joon Lee; Sang-Jin Sung; Youn-Sic Chun; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2016-07-25       Impact factor: 1.372

3.  Incorporation of silver nanoparticles on the surface of orthodontic microimplants to achieve antimicrobial properties.

Authors:  Adith Venugopal; Nallal Muthuchamy; Harsh Tejani; Anantha-Iyengar Gopalan; Kwang-Pill Lee; Heon-Jin Lee; Hee Moon Kyung
Journal:  Korean J Orthod       Date:  2016-12-19       Impact factor: 1.372

4.  Effect of surface treatment on the mechanical stability of orthodontic miniscrews.

Authors:  Yousef Al-Thomali; Sakeenabi Basha; Roshan Noor Mohamed
Journal:  Angle Orthod       Date:  2022-01-01       Impact factor: 2.079

5.  Tooth movement out of the bony wall using augmented corticotomy with nonautogenous graft materials for bone regeneration.

Authors:  Kye-Bok Lee; Dong-Yeol Lee; Hyo-Won Ahn; Seong-Hun Kim; Eun-Cheol Kim; Igor Roitman
Journal:  Biomed Res Int       Date:  2014-08-27       Impact factor: 3.411

6.  Effects of recycling on the biomechanical characteristics of retrieved orthodontic miniscrews.

Authors:  Soon-Dong Yun; Sung-Hwan Choi; Jung-Yul Cha; Hyung-Seog Yu; Kwang-Mahn Kim; Jin Kim; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2017-05-26       Impact factor: 1.372

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.