Literature DB >> 9589548

Anatomic considerations of pedicle screw placement in the thoracic spine. Roy-Camille technique versus open-lamina technique.

R Xu1, N A Ebraheim, Y Ou, R A Yeasting.   

Abstract

STUDY
DESIGN: In this cadaveric study, the outcomes of two techniques for pedicle screw placement in the thoracic spine were compared.
OBJECTIVES: To assess the Roy-Camille technique, and to determine whether pedicle screw placement, aided by partial laminectomy, could decrease the incidence of pedicle violations. SUMMARY OF BACKGROUND DATA: Pedicle screw fixation in the thoracic spine remains technically challenging. The Roy-Camille method may be one of the leading techniques of thoracic pedicle screw placement. However, there are few studies evaluating this technique and determining methods to decrease the incidence of thoracic pedicle penetration with screw insertion.
METHODS: Ten cadaveric thoracic spines from T1 to T10 were used for pedicle screw placement. Two techniques of transpedicular screw placement were used, the Roy-Camille technique (screw placed on the right side; used in 95 screw placements) and the open-lamina technique screw placement with combined partial laminectomy (screw placed on the left side; used in 94 screw placements). After screw placement, all specimens were evaluated visually to determine violation of the pedicle.
RESULTS: The screw placement with the Roy-Camille technique had a higher percentage of pedicle violation (54.7%) than did that with the open-lamina technique (15.9%). No Grade III violation was seen in the screw placement with the open-lamina technique.
CONCLUSIONS: The Roy-Camille technique was associated with a high incidence of pedicle violation, whereas screw placement with a partial laminectomy significantly reduced the incidence of pedicle violation. Pedicle screw fixation in the thoracic spine remains a technical challenge and should not be used routinely. Screw placement with the open-lamina technique is recommended if pedicle screw fixation is strongly indicated in the thoracic spine.

Mesh:

Year:  1998        PMID: 9589548     DOI: 10.1097/00007632-199805010-00021

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  40 in total

1.  [Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique].

Authors:  K J Schnake; B König; U Berth; R J Schroeder; F Kandziora; U Stöckle; M Raschke; N P Haas
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

2.  A new 3-dimensional method for measuring precision in surgical navigation and methods to optimize navigation accuracy.

Authors:  Christopher J Kleck; Ian Cullilmore; Matthew LaFleur; Emily Lindley; Mark E Rentschler; Evalina L Burger; Christopher M J Cain; Vikas V Patel
Journal:  Eur Spine J       Date:  2015-09-22       Impact factor: 3.134

3.  Comparison of pullout strength of the thoracic pedicle screw between intrapedicular and extrapedicular technique: a meta-analysis and literature review.

Authors:  Hua Wang; Huafeng Wang; Shilabant Sen Sribastav; Fubiao Ye; Chunxiang Liang; Zemin Li; Jianru Wang; Hui Liu; Xin Wang; Zhaomin Zheng
Journal:  Int J Clin Exp Med       Date:  2015-12-15

4.  A preliminary study of reliability of impedance measurement to detect iatrogenic initial pedicle perforation (in the porcine model).

Authors:  Ciaran Bolger; C Carozzo; T Roger; Linda McEvoy; Jabir Nagaria; Gerard Vanacker; Maurice Bourlion
Journal:  Eur Spine J       Date:  2005-10-13       Impact factor: 3.134

5.  Alignment of pedicle screws with pilot holes: can tapping improve screw trajectory in thoracic spines?

Authors:  Serkan Erkan; Brian Hsu; Chunhui Wu; Amir A Mehbod; John Perl; Ensor E Transfeldt
Journal:  Eur Spine J       Date:  2009-06-14       Impact factor: 3.134

Review 6.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

7.  Pedicle morphometry for thoracic screw fixation in ethnic koreans : radiological assessment using computed tomographic myelography.

Authors:  Yong Soo Choi; Young Jin Kim; Hyeong-Joong Yi; Young-Joon Kim
Journal:  J Korean Neurosurg Soc       Date:  2009-10-31

8.  Recording triggered EMG thresholds from axillary chest wall electrodes: a new refined technique for accurate upper thoracic (T2-T6) pedicle screw placement.

Authors:  Ignacio Regidor; Gema de Blas; Carlos Barrios; Jesús Burgos; Elena Montes; Sergio García-Urquiza; Edurado Hevia
Journal:  Eur Spine J       Date:  2011-04-22       Impact factor: 3.134

9.  Technical Report of Free Hand Pedicle Screw Placement using the Entry Points with Junction of Proximal Edge of Transverse Process and Lamina in Lumbar Spine: Analysis of 2601 Consecutive Screws.

Authors:  Chang Hyun Oh; Seung Hwan Yoon; Yongjung J Kim; Dongkeun Hyun; Hyeong-Chun Park
Journal:  Korean J Spine       Date:  2013-03-31

10.  Inserting pedicle screws in lumbar spondylolisthesis - The easy bone conserving way.

Authors:  Hitesh Lal; Lalit Kumar; Ramesh Kumar; Tankeshwar Boruah; Pankaj Kumar Jindal; Vinod Kumar Sabharwal
Journal:  J Clin Orthop Trauma       Date:  2017-03-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.