Literature DB >> 9587999

Validation of a new blood-mimicking fluid for use in Doppler flow test objects.

K V Ramnarine1, D K Nassiri, P R Hoskins, J Lubbers.   

Abstract

A blood-mimicking fluid (BMF) suitable for use in Doppler flow test objects is described and characterised. The BMF consists of 5 microns diameter nylon scattering particles suspended in a fluid base of water, glycerol, dextran and surfactant. The acoustical properties of various BMF preparations were measured under uniform flow to study the effects of particle size, particle concentration, surfactant concentration, flow rate and stability. The physical properties, (density, viscosity and particle size), and acoustical properties (velocity, backscatter and attenuation) of the BMF are within draft International Electrotechnical Commission requirements.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9587999     DOI: 10.1016/s0301-5629(97)00277-9

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  42 in total

1.  Pulsatile flow phantom for ultrasound image-guided HIFU treatment of vascular injuries.

Authors:  Robyn Greaby; Vesna Zderic; Shahram Vaezy
Journal:  Ultrasound Med Biol       Date:  2007-04-27       Impact factor: 2.998

2.  A System for Simple Real-Time Anastomotic Failure Detection and Wireless Blood Flow Monitoring in the Lower Limbs.

Authors:  Michael A Rothfuss; Nicholas G Franconi; Jignesh V Unadkat; Michael L Gimbel; Alexander Star; Marlin H Mickle; Ervin Sejdic
Journal:  IEEE J Transl Eng Health Med       Date:  2016-08-25       Impact factor: 3.316

3.  Evaluation of distal turbulence intensity for the detection of both plaque ulceration and stenosis grade in the carotid bifurcation using clinical Doppler ultrasound.

Authors:  Emily Y Wong; Hristo N Nikolov; Richard N Rankin; David W Holdsworth; Tamie L Poepping
Journal:  Eur Radiol       Date:  2012-12-18       Impact factor: 5.315

4.  Coded Spectral Doppler Imaging: From Simulation to Real-Time Processing.

Authors:  Alessandro Ramalli; Enrico Boni; Alessandro Dallai; Francesco Guidi; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-26       Impact factor: 2.725

5.  Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties.

Authors:  Alvin I Chen; Max L Balter; Melanie I Chen; Daniel Gross; Sheikh K Alam; Timothy J Maguire; Martin L Yarmush
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

6.  Easy Pulsatile Phantom for Teaching and Validation of Flow Measurements in Ultrasound.

Authors:  M B Rominger; E-M Müller-Stuler; M Pinto; A S Becker; K Martini; T Frauenfelder; V Klingmüller
Journal:  Ultrasound Int Open       Date:  2016-07-13

Review 7.  Current understanding of intimal hyperplasia and effect of compliance in synthetic small diameter vascular grafts.

Authors:  YeJin Jeong; Yuan Yao; Evelyn K F Yim
Journal:  Biomater Sci       Date:  2020-07-09       Impact factor: 6.843

8.  Development of a flexible implantable sensor for postoperative monitoring of blood flow.

Authors:  Jonathan M Cannata; Thomas Chilipka; Hao-Chung Yang; Sukgu Han; Sung W Ham; Vincent L Rowe; Fred A Weaver; K Kirk Shung; David Vilkomerson
Journal:  J Ultrasound Med       Date:  2012-11       Impact factor: 2.153

9.  Role of ultrasonic shear rate estimation errors in assessing inflammatory response and vascular risk.

Authors:  Jean K Tsou; Jie Liu; Abdul I Barakat; Michael F Insana
Journal:  Ultrasound Med Biol       Date:  2008-01-22       Impact factor: 2.998

10.  Poly(vinyl alcohol) gel ultrasound phantom with durability and visibility of internal flow.

Authors:  Kenichi Funamoto; Osamu Yamashita; Toshiyuki Hayase
Journal:  J Med Ultrason (2001)       Date:  2014-08-05       Impact factor: 1.314

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.