Literature DB >> 15191085

Natural frequency assessment of stability of root keeper magnetic devices.

H M Huang1, D Z Liu, Y Y Shiau, C Y Yeh, C T Lin, S Y Lee.   

Abstract

The aim of the study was to evaluate the potential for using natural frequency (NF) as an indicator for assessing the stability of a magnetic keeper device used in prosthodontic treatment. A three-dimensional finite element (FE) model of a root keeper-cement-dentine system was established for NF analysis. The model was first validated against a series of in vitro experiments. Then, NF values of the first vibrational mode of the FE model with various boundary conditions were calculated. The in vitro results showed that the measured NF values of the root keeper-incisor units decreased significantly (p<0.01) from 9.07 +/- 0.37 to 5.73 +/- 0.10 kHz when the units were embedded in simulated bony tissue. Results obtained from FE simulations demonstrated that the root keeper would fully loosen when the constant values of the spring elements were lower than 10(4) N-m(-1). Furthermore, a linear increase in the NF values of the model was observed from 6.16 to 15.52 kHz, when the constant was increased from 10(4) to 10(7) N-m(-1), and the values then reached a plateau. The results indicate that the NF value of a root keeper has the potential to be used for monitoring the stability of such a device.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15191085     DOI: 10.1007/bf02344715

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  35 in total

Review 1.  The use of low-frequency vibration measurement in orthopaedics.

Authors:  L D Nokes
Journal:  Proc Inst Mech Eng H       Date:  1999       Impact factor: 1.617

Review 2.  Magnets in prosthetic dentistry.

Authors:  M A Riley; A D Walmsley; I R Harris
Journal:  J Prosthet Dent       Date:  2001-08       Impact factor: 3.426

3.  Nondestructive estimation of the strength of dental ceramic materials.

Authors:  H Fischer; G Dautzenberg; R Marx
Journal:  Dent Mater       Date:  2001-07       Impact factor: 5.304

4.  Axial vibration of threaded external fixation pins: detection of pin loosening.

Authors:  M W Kay; S C Roe; L F Stikeleather; A Mahmoud; C F Abrams
Journal:  Ann Biomed Eng       Date:  1998 May-Jun       Impact factor: 3.934

5.  The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia.

Authors:  N Meredith; F Shagaldi; D Alleyne; L Sennerby; P Cawley
Journal:  Clin Oral Implants Res       Date:  1997-06       Impact factor: 5.977

6.  Retentive characteristics of different magnetic systems for dental applications.

Authors:  R Highton; A A Caputo; M Pezzoli; J Matyas
Journal:  J Prosthet Dent       Date:  1986-07       Impact factor: 3.426

7.  Magnetic force in orthodontics.

Authors:  A M Blechman; H Smiley
Journal:  Am J Orthod       Date:  1978-10

8.  Three-dimensional finite element analysis of the effects of posts on stress distribution in dentin.

Authors:  M H Ho; S Y Lee; H H Chen; M C Lee
Journal:  J Prosthet Dent       Date:  1994-10       Impact factor: 3.426

9.  Magnetic retention for overdentures. Part II.

Authors:  B R Gillings
Journal:  J Prosthet Dent       Date:  1983-05       Impact factor: 3.426

10.  Magnetic retention for complete and partial overdentures. Part I.

Authors:  B R Gillings
Journal:  J Prosthet Dent       Date:  1981-05       Impact factor: 3.426

View more
  2 in total

1.  Radiofrequency heating and magnetically induced displacement of dental magnetic attachments during 3.0 T MRI.

Authors:  K Miyata; M Hasegawa; Y Abe; T Tabuchi; T Namiki; T Ishigami
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  Non-destructive natural frequency tests of cyclic fatigue-loaded nickel-titanium rotary instruments.

Authors:  Sung-Chih Hsieh; Sheng-Yang Lee; Chun-Yu Ciou; Haw-Ming Huang
Journal:  Med Biol Eng Comput       Date:  2010-06       Impact factor: 2.602

  2 in total