Literature DB >> 9553570

Jumbo cups and morsalized graft.

M Jasty1.   

Abstract

Revision of failed acetabular components presents a formidable problem due to associated loss of bone and sclerosis of the remaining bone. Uncemented acetabular components with porous surfaces have revolutionized acetabular revision surgery. They can be stabilized into the existing host bone with supplemental screws even in the face of major bone loss. Nonstructural particulate bone grafts can then be used to supplement the bone stock. With large defects, jumbo acetabular components ranging in sizes from 70 to 80 millimeter outer diameters can be stabilized on the acetabular rim while the defects can be grafted with morsalized bone. Nineteen of such revisions performed for major bone loss without pelvic discontinuity between February 1986 and December 1988 were evaluated at a mean follow-up period of ten years (range eight to eleven years). One component had been revised for sepsis. None of the others had been revised. Definite radiographic failure of fixation of the acetabular component was not seen on any of the other hips. These results strongly support the use of jumbo uncemented acetabular components with morsalized bone grafts even in the face of major acetabular bone loss.

Entities:  

Mesh:

Year:  1998        PMID: 9553570     DOI: 10.1016/s0030-5898(05)70323-0

Source DB:  PubMed          Journal:  Orthop Clin North Am        ISSN: 0030-5898            Impact factor:   2.472


  15 in total

1.  Do jumbo cups cause hip center elevation in revision THA? A computer simulation.

Authors:  Chima Nwankwo; Nick N Dong; Christopher D Heffernan; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

2.  A review of the treatment of pelvic discontinuity.

Authors:  M Villanueva; A Rios-Luna; J Pereiro De Lamo; H Fahandez-Saddi; M P G Böstrom
Journal:  HSS J       Date:  2008-07-15

3.  Segmental acetabular rim defects, bone loss, oversizing, and press fit cup in total hip arthroplasty evaluated with a probabilistic finite element analysis.

Authors:  Farid Amirouche; Giovanni F Solitro; Amit Walia; Mark Gonzalez; Aimee Bobko
Journal:  Int Orthop       Date:  2016-12-23       Impact factor: 3.075

4.  Acetabular cup positioning in revision total hip arthroplasty with Paprosky type III acetabular defects: Martell radiographic analysis.

Authors:  Ho-Rim Choi; David Anderson; Scott Foster; Matthew Beal; Jo Ann Lee; Christopher Barr; Henrik Malchau; Joseph McCarthy; Young-Min Kwon
Journal:  Int Orthop       Date:  2013-07-24       Impact factor: 3.075

5.  Results of the cementless Plasmacup in revision total hip arthroplasty: a retrospective study of 72 cases with an average follow-up of eight years.

Authors:  Stefan Lakemeier; Guenter Aurand; Nina Timmesfeld; Thomas J Heyse; Susanne Fuchs-Winkelmann; Markus D Schofer
Journal:  BMC Musculoskelet Disord       Date:  2010-05-27       Impact factor: 2.362

6.  Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup.

Authors:  Martín A Buttaro; Fernando Comba; Rodolfo Pusso; Francisco Piccaluga
Journal:  Clin Orthop Relat Res       Date:  2008-08-13       Impact factor: 4.176

7.  Do jumbo cups cause hip center elevation in revision THA? A radiographic evaluation.

Authors:  Chima D Nwankwo; Michael D Ries
Journal:  Clin Orthop Relat Res       Date:  2014-04-18       Impact factor: 4.176

8.  Cementless jumbo cups for revision of failed Furlong prosthesis. A case series.

Authors:  Ahmed Salem Eid; Ahmed Kotb; Waleed Elshabrawy
Journal:  J Clin Orthop Trauma       Date:  2018-08-11

Review 9.  Rationale for one stage exchange of infected hip replacement using uncemented implants and antibiotic impregnated bone graft.

Authors:  Heinz Winkler
Journal:  Int J Med Sci       Date:  2009-09-04       Impact factor: 3.738

10.  Two stage cementation and screw augmentation of large acetabular defects in low demand patients: Early results and surgical technique.

Authors:  Mohamed Mussa; Varun Dewan; Eric Isbister
Journal:  J Orthop       Date:  2019-09-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.