Stethoscopes and otoscopes--a potential vector of infection?

H A Cohen1, J Amir, A Matalon, R Mayan, S Beni, A Barzilai.   

Abstract

OBJECTIVES: We aimed to determine whether stethoscopes and otoscopes used in community paediatric clinics harboured pathogenic micro-organisms, and, if so, which measures could prevent this.
METHODS: Fifty-five stethoscopes belonging to paediatric physicians working in 12 community clinics were sampled for bacterial cultures by two methods: (i) direct impression of the diaphragm and bell section of each stethoscope for 5 seconds onto blood agar plates and a mannitol-salt-agar plate; (ii) swabbing the entire surface of the diaphragm of the stethoscope with a sterile cotton-tipped applicator. Forty-two otoscopes from the same physicians were sampled by rubbing the handles of the otoscopes with cotton-tipped swabs. The plates were incubated at 37 degrees C for 48 hours and examined for colony growth at 24 and 48 hours of incubation. Culture results were recorded as mean numbers of colony-forming units (CFUs). Eight additional stethoscope diaphragms were chosen at random at the participating clinics and cultured as described above. They were then wiped with alcohol swabs (isopropyl alcohol 70%), allowed to air dry for approximately 10 minutes and cultured a second time.
RESULTS: All the stethoscopes and 90% of the otoscope handles were colonized by microorganisms. Staphylococci were isolated from 85.4% of the stethoscopes and 83.3% of the otoscopes, with 54.5% and 45.2% respectively being S. Aureus. Methicillin-resistant S. aureus were found in four each of the stethoscopes (7.3%) and otoscopes (9.5%). Cleaning with alcohol reduced the colony count by an average of 96.3%.
CONCLUSIONS: Fomites can harbour potentially pathogenic bacteria, and with the increasing trend for children with more complex medical problems to be managed in an ambulatory setting, often by physicians who also work in hospitals, there is a real risk of spreading potentially serious infections to such patients. Simple cleansing with alcohol effectively eliminates the bacterial contamination of the fomites, and should be encouraged.

Entities:  

Mesh:

Year:  1997        PMID: 9476074     DOI: 10.1093/fampra/14.6.446

Source DB:  PubMed          Journal:  Fam Pract        ISSN: 0263-2136            Impact factor:   2.267


  18 in total

Review 1.  MRSA and the environment: implications for comprehensive control measures.

Authors:  N Cimolai
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2008-02-14       Impact factor: 3.267

2.  Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital.

Authors:  Teklu Shiferaw; Getenet Beyene; Tesfaye Kassa; Tsegaye Sewunet
Journal:  Ann Clin Microbiol Antimicrob       Date:  2013-12-13       Impact factor: 3.944

3.  A prospective study of the case-notes of MRSA-positive patients: a vehicle of MRSA spread.

Authors:  N Hamza; G Bazoua; Y Al-Shajerie; E Kubiak; P James; C Wong
Journal:  Ann R Coll Surg Engl       Date:  2007-10       Impact factor: 1.891

4.  Testing wound dressings using an in vitro wound model.

Authors:  C Lipp; K Kirker; A Agostinho; G James; P Stewart
Journal:  J Wound Care       Date:  2010-06       Impact factor: 2.072

5.  Contamination and decontamination of Doppler probes.

Authors:  Emma J Whitehead; John F Thompson; David R Lewis
Journal:  Ann R Coll Surg Engl       Date:  2006-09       Impact factor: 1.891

6.  Using marker pens on patients: a potential source of cross infection with MRSA.

Authors:  S Tadiparthi; K Shokrollahi; A Juma; J Croall
Journal:  Ann R Coll Surg Engl       Date:  2007-10       Impact factor: 1.891

7.  The risk of cross-infection when marking surgical patients prior to surgery - review of two types of marking pens.

Authors:  M S G Ballal; N Shah; M Ballal; M O'Donoghue; D J Pegg
Journal:  Ann R Coll Surg Engl       Date:  2007-04       Impact factor: 1.891

8.  Comparing the auscultatory accuracy of health care professionals using three different brands of stethoscopes on a simulator.

Authors:  Mansoor Mehmood; Hazem L Abu Grara; Joshua S Stewart; Faisal A Khasawneh
Journal:  Med Devices (Auckl)       Date:  2014-08-14

9.  Knowledge, Attitude, and Practices of Healthcare Personnel Regarding the Transmission of Pathogens via Fomites at a Tertiary Care Hospital in Karachi, Pakistan.

Authors:  Hassaan Bin Aftab; Bushra Zia; Mohammad Faizan Zahid; Ahmed Raheem; Mohammad Asim Beg
Journal:  Open Forum Infect Dis       Date:  2015-12-22       Impact factor: 4.423

10.  The bacterial contamination rate of glucose meter test strips in the hospital setting.

Authors:  Khalid A Al-Rubeaan; Amr T M Saeb; Dhekra M AlNaqeb; Hamid M AlQumaidi; Turki A AlMogbel
Journal:  Saudi Med J       Date:  2016-09       Impact factor: 1.484

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.