Literature DB >> 9474623

Validity of radiographic measurement of interproximal bone loss.

P Eickholz1, T S Kim, D K Benn, H J Staehle.   

Abstract

The aim of the present study was to compare radiographic assessment of interproximal bone loss using a loupe with a 0.1 mm calibrated grid and a computer-assisted analysis system (LMSRT). In 35 patients suffering from untreated advanced periodontal disease, 62 standardized radiographs were taken presurgically. The horizontal and vertical angulation difference of the central beam from the orthoradial projection was calculated for each radiograph. At the time of surgery, for 115 interproximal defects, the distances from the cementoenamel junction (CEJ) to alveolar crest (AC), and CEJ to bottom of the bony defect (BD) were measured. In all radiographs, the linear distances CEJ to AC, and CEJ to BD were assessed using a loupe and LMSRT. Comparison between radiographic and intrasurgical assessments was performed using paired t-tests. A stepwise multiple linear regression analysis was used to evaluate factors that influence the discrepancy between radiographic and intrasurgical measurements. Both analyzing techniques underestimated interproximal bone loss as compared with intrasurgical measurements (CEJ-AC: loupe: 0.86 +/- 1.84 mm [p < 0.001]; LMSRT: 0.58 +/- 1.86 mm [p < 0.005]; CEJ-BD: loupe: 1.22 +/- 2.33 mm [p < 0.001]; LMSRT: 0.80 +/- 2.09 mm [p < 0.001]). LMSRT underestimated interproximal bone loss significantly less than the loupe (p < 0.001). The difference between LMSRT and intrasurgical assessments was modulated by the factors of vertical and horizontal angulation difference and defect depth (p < 0.1). Orthoradial projection reduced underestimation of radiographic assessment of bone loss. LMSRT underestimated interproximal bone loss to a lesser extent than conventional evaluation by loupe.

Entities:  

Mesh:

Year:  1998        PMID: 9474623     DOI: 10.1016/s1079-2104(98)90406-1

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  17 in total

1.  A method for segmentation of dental implants and crestal bone.

Authors:  Pedro Cunha; Miguel A Guevara; Ana Messias; Salomão Rocha; Rita Reis; Pedro M G Nicolau
Journal:  Int J Comput Assist Radiol Surg       Date:  2012-12-02       Impact factor: 2.924

2.  Effectiveness of a personalized device in the evaluation of mandibular second molar periodontal healing after surgical extraction of adjacent third molar.

Authors:  Roberto Pippi
Journal:  Ann Stomatol (Roma)       Date:  2014-02-04

3.  Detection of simulated periodontal defects using cone-beam CT and digital intraoral radiography.

Authors:  Samaneh Bayat; Ahmad Reza Talaeipour; Fatemeh Sarlati
Journal:  Dentomaxillofac Radiol       Date:  2016-05-18       Impact factor: 2.419

4.  Comparison of diagnostic accuracy of conventional intraoral periapical and direct digital radiographs in detecting interdental bone loss.

Authors:  S R Ashwinirani; Girish Suragimath; H P Jaishankar; Prasad Kulkarni; Shobha C Bijjaragi; Varsha Ajit Sangle
Journal:  J Clin Diagn Res       Date:  2015-02-01

Review 5.  Precision of cone beam CT to assess periodontal bone defects: a systematic review and meta-analysis.

Authors:  Letícia Fernanda Haas; Glaucia Santos Zimmermann; G De Luca Canto; Carlos Flores-Mir; Márcio Corrêa
Journal:  Dentomaxillofac Radiol       Date:  2017-10-27       Impact factor: 2.419

6.  Pose determination of a blade implant in three dimensions from a single two-dimensional radiograph.

Authors:  Paolo Toti; Antonio Barone; Simone Marconcini; Giovanni Battista Menchini-Fabris; Ranieri Martuscelli; Ugo Covani
Journal:  Dentomaxillofac Radiol       Date:  2018-01-11       Impact factor: 2.419

7.  Detection of periodontal bone loss using cone beam CT and intraoral radiography.

Authors:  K de Faria Vasconcelos; K M Evangelista; C D Rodrigues; C Estrela; T O de Sousa; M A G Silva
Journal:  Dentomaxillofac Radiol       Date:  2012-01       Impact factor: 2.419

8.  Influence of image filters on the reproducibility measurements of alveolar bone loss.

Authors:  Wivian Eiras Garcia Wong Alves; Evelise Ono; Jefferson Luis Oshiro Tanaka; Titular Edmundo Medici Filho; Luiz César de Moraes; Mari Eli Leonelli de Moraes; Julio Cezar de Melo Castilho
Journal:  J Appl Oral Sci       Date:  2006-12       Impact factor: 2.698

9.  Measurements of simulated periodontal bone defects in inverted digital image and film-based radiograph: an in vitro study.

Authors:  Rafael Scaf de Molon; Juliana Aparecida Najarro Dearo Morais-Camillo; Celso Eduardo Sakakura; Mauricio Goncalves Ferreira; Leonor Castro Monteiro Loffredo; Gulnara Scaf
Journal:  Imaging Sci Dent       Date:  2012-12-23

10.  Comparison of CBCT with different voxel sizes and intraoral scanner for detection of periodontal defects: an in vitro study.

Authors:  Murat Icen; Kaan Orhan; Çiğdem Şeker; Gediz Geduk; Fethiye Cakmak Özlü; Murat İnanç Cengiz
Journal:  Dentomaxillofac Radiol       Date:  2020-03-10       Impact factor: 2.419

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.