Literature DB >> 19089241

Influence of image filters on the reproducibility measurements of alveolar bone loss.

Wivian Eiras Garcia Wong Alves1, Evelise Ono, Jefferson Luis Oshiro Tanaka, Titular Edmundo Medici Filho, Luiz César de Moraes, Mari Eli Leonelli de Moraes, Julio Cezar de Melo Castilho.   

Abstract

The reproducibility of measurements of alveolar bone loss on radiographs may be a problem on epidemiologic studies, as they are based on comparisons of the diagnosis of various examiners. The aim of the present research paper was to assess the inter- and intra-examiner reproducibility of measurements of the interproximal alveolar bone loss on non-manipulated digital radiographs and after the application of image filters. Five Oral Radiologists measured the distance between the cementoenamel junction (CEJ) to the alveolar crest or to the deepest point of the bony defect on 12 interproximal digital radiographs of molars and bicuspids of a dry human skull. The digital manipulation and the linear measurements were obtained with the Trophy Windows software (Throphy). For each image, six different versions were created: 1) non-manipulated; 2) bright-contrast adjustment; 3) negative; 4) negative with brightness-contrast adjustment; 5) pseudo-colored; 6) pseudo-colored with brightness-contrast adjustment. In order to prevent interpretation bias because of the repetition of measurements, the examiners measured the radiographs in a random sequence. The two-way ANOVA test at 5% level of significance to compare the means of readings of the same operator with each filter indicated p<0.05 for the majority of operators, while the comparison between the mean values of operators using the same filter indicated p>0.05 for all filters. Based on the results, we concluded that linear measurements of interproximal alveolar bone loss on digital radiographs are highly reproducible among examiners. Nevertheless, the application of image filters significantly influenced the degree of intra-examiner reproducibility. Some filters even reduced the reproducibility of intra-examiner readings.

Entities:  

Year:  2006        PMID: 19089241      PMCID: PMC4327293          DOI: 10.1590/s1678-77572006000600006

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  17 in total

Review 1.  Radiographic and digital imaging in periodontal practice.

Authors:  E Hausmann
Journal:  J Periodontol       Date:  2000-03       Impact factor: 6.993

2.  Digital radiography of interproximal bone loss; validity of different filters.

Authors:  P Eickholz; T Riess; M Lenhard; S Hassfeld; H J Staehle
Journal:  J Clin Periodontol       Date:  1999-05       Impact factor: 8.728

3.  Periodontal disease morbidity quantification. II. Validation of alveolar bone loss measurements and vertical defect diagnosis from digital bite-wing images.

Authors:  C F Hildebolt; M W Vannier; M K Shrout; T K Pilgram; M Province; E P Vahey; D W Rietz
Journal:  J Periodontol       Date:  1990-10       Impact factor: 6.993

4.  Effect of x-ray beam vertical angulation on radiographic alveolar crest level measurement.

Authors:  E Hausmann; K Allen; L Christersson; R J Genco
Journal:  J Periodontal Res       Date:  1989-01       Impact factor: 4.419

5.  Diagnostic accuracy of direct digital dental radiography for the detection of periapical bone lesions. II. Effects on diagnostic accuracy after application of image processing.

Authors:  B Kullendorff; M Nilsson
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1996-11

6.  Validity of radiographic measurement of interproximal bone loss.

Authors:  P Eickholz; T S Kim; D K Benn; H J Staehle
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-01

Review 7.  Radiographic diagnosis in periodontics.

Authors:  M K Jeffcoat; I C Wang; M S Reddy
Journal:  Periodontol 2000       Date:  1995-02       Impact factor: 7.589

8.  Accuracy of caries diagnosis in digital images from charge-coupled device and storage phosphor systems: an in vitro study.

Authors:  A Wenzel; E Borg; H Hintze; H G Gröndahl
Journal:  Dentomaxillofac Radiol       Date:  1995-11       Impact factor: 2.419

9.  The effects of incremental brightness and contrast adjustments on radiographic data: a quantitative study.

Authors:  P Güneri; G Lomçali; H Boyacioğlu; S Kendir
Journal:  Dentomaxillofac Radiol       Date:  2005-01       Impact factor: 2.419

10.  Reliability of linear alveolar bone loss measurements of mandibular posterior teeth from digitized bitewing radiographs.

Authors:  C F Hildebolt; T K Pilgram; N Yokoyama-Crothers; G Fletcher; J L Helbig; T Q Bartlett; M Gravier; M W Vannier; M K Shrout
Journal:  J Clin Periodontol       Date:  1998-11       Impact factor: 8.728

View more
  3 in total

1.  Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography.

Authors:  Wilton Mitsunari Takeshita; Lilian Cristina Vessoni Iwaki; Mariliani Chicarelli Da Silva; Liogi Iwaki Filho; Alfredo De Franco Queiroz; Lucas Bachegas Gomes Geron
Journal:  Contemp Clin Dent       Date:  2013-07

2.  Assessment of diagnostic accuracy of a direct digital radiographic-CMOS image with four types of filtered images for the detection of occlusal caries.

Authors:  Rohit Kumar Sahu; Jagadish P Rajguru; Naina Pattnaiak; Debajyoti Bardhan; Bikash Nayak
Journal:  J Family Med Prim Care       Date:  2020-01-28

3.  Image enhancement of digital periapical radiographs according to diagnostic tasks.

Authors:  Jin-Woo Choi; Won-Jeong Han; Eun-Kyung Kim
Journal:  Imaging Sci Dent       Date:  2014-03-19
  3 in total