Literature DB >> 9458248

5- to 13-year follow-up study on cementless femoral components in revision surgery.

A B Krishnamurthy1, S J MacDonald, W G Paprosky.   

Abstract

The 5- to 13-year follow-up data on 297 cementless revision arthroplasties with extensively coated components (Anatomic Medullary Locking femoral component, DePuy, Warsaw, IN) are reported. A basic classification of the femoral defects was developed. All patients were evaluated clinically and radiographically at a minimum of 60 months. Clinically, the average Postel-d'Aubigné score improved from 4.8 before to a 10.2 after surgery. Definite radiographic instability was noted in seven hips. Five patients were symptomatic and were revised. The mechanical failure rate was 2.4%. The overall complication rate was 5.7%, with a 2.6% dislocation rate. In the presence of bone loss in the proximal metaphyseal region of the femur, fixation of the femoral component is best achieved in the diaphyseal region of the femur using an extensively coated femoral component.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9458248     DOI: 10.1016/s0883-5403(97)90152-2

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  29 in total

1.  Are short fully coated stems adequate for "simple" femoral revisions?

Authors:  Matthew W Tetreault; Sanjai K Shukla; Paul H Yi; Scott M Sporer; Craig J Della Valle
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

2.  Femoral revision with an extensively hydroxyapatite-coated femoral component.

Authors:  Lawrence V Gulotta; Andreas Baldini; Kristin Foote; Stephen Lyman; Bryan J Nestor
Journal:  HSS J       Date:  2007-12-01

3.  The long modified extended sliding trochanteric osteotomy.

Authors:  Dror Lakstein; Yona Kosashvili; David Backstein; Oleg Safir; Paul Lee; Allan E Gross
Journal:  Int Orthop       Date:  2009-10-16       Impact factor: 3.075

4.  Femoral revision hip arthroplasty: a comparison of two stem designs.

Authors:  Corey J Richards; Clive P Duncan; Bassam A Masri; Donald S Garbuz
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

5.  Increase of cortical bone after a cementless long stem in periprosthetic fractures.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo; Ana Cruz-Pardos; Rosário Madero
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

6.  Bone stock in revision femoral arthroplasty: a new evaluation.

Authors:  François Canovas; Julien Girard; Olivier Roche; Henri Migaud; François Bonnomet; Mathias Goldschild; Pierre Le Béguec
Journal:  Int Orthop       Date:  2015-01-08       Impact factor: 3.075

7.  Bone remodeling after a mean of 10 years in diaphyseal cortical defects repaired with femoral revision using bypass fixation of extensively porous-coated stems with high stiffness.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Tadami Matsumoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-01-04

8.  Revision hip arthroplasty using a cementless modular tapered stem.

Authors:  Christophe Pattyn; Alexander Mulliez; René Verdonk; Emmanuel Audenaert
Journal:  Int Orthop       Date:  2011-06-24       Impact factor: 3.075

9.  Distal femoral stem-bone anchorage of a cementless revision total hip arthroplasty: evaluation of 14 patients by CT.

Authors:  Rüdiger J Weiss; Fredrik Strömwall; Mats O Beckman; Karl A Hansson; André Stark
Journal:  Acta Orthop       Date:  2009-06       Impact factor: 3.717

10.  Femoral revision surgery using a fully hydroxyapatite-coated stem: a cohort study of twenty two to twenty seven years.

Authors:  Olav Reikerås
Journal:  Int Orthop       Date:  2016-04-30       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.