Literature DB >> 18751863

Femoral revision with an extensively hydroxyapatite-coated femoral component.

Lawrence V Gulotta1, Andreas Baldini, Kristin Foote, Stephen Lyman, Bryan J Nestor.   

Abstract

Between December 1996 and April 2003, 26 consecutive femoral component revisions in 24 patients were performed with an extensively hydroxyapatite-coated femoral stem. Two patients were lost to follow-up, and two patients died of unrelated causes. Of the 22 femoral revisions in 20 patients, there was a 0% incidence of mechanical loosening at average follow-up of 3.2 years (2-6.3 years). The Harris Hip Score improved from 59 (36 to 83) to 95 (84 to 100) postoperatively (p < 0.001). Rate of revision was 18.2% (4.5% for sepsis, 9.1% for instability, and 4.5% for polyethelene wear). All 22 femoral components had evidence of bone ingrowth. The extensively coated hydroxyapatite stem in this series produced excellent clinical results with a low incidence of thigh pain (4.5%) and severe stress shielding (4.5%).

Entities:  

Year:  2007        PMID: 18751863      PMCID: PMC2504273          DOI: 10.1007/s11420-007-9068-x

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  33 in total

1.  Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty.

Authors:  W G Paprosky; N V Greidanus; J Antoniou
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

2.  A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem.

Authors:  M J Coathup; G W Blunn; N Flynn; C Williams; N P Thomas
Journal:  J Bone Joint Surg Br       Date:  2001-01

3.  Is the Harris hip score system useful to study the outcome of total hip replacement?

Authors:  P Söderman; H Malchau
Journal:  Clin Orthop Relat Res       Date:  2001-03       Impact factor: 4.176

4.  Stem design and dislocation after revision total hip arthroplasty: clinical results and computer modeling.

Authors:  R L Barrack; R A Butler; D R Laster; P Andrews
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

5.  A titanium cementless calcar replacement prosthesis in revision surgery of the femur: 13-year experience.

Authors:  W C Head; R H Emerson; L L Higgins
Journal:  J Arthroplasty       Date:  2001-12       Impact factor: 4.757

6.  Hydroxyapatite-coated femoral implant in metal-on-metal resurfacing hip arthroplasty: minimum of two years follow-up.

Authors:  Anastasios K Lilikakis; Sarah L Vowler; Richard N Villar
Journal:  Orthop Clin North Am       Date:  2005-04       Impact factor: 2.472

7.  The Harris hip score: comparison of patient self-report with surgeon assessment.

Authors:  N N Mahomed; D C Arndt; B J McGrory; W H Harris
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

8.  Cementless femoral revision arthroplasty of the hip: minimum 5 years followup.

Authors:  J R Moreland; M A Moreno
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

9.  Clinical and radiographic analysis of the Mallory-Head femoral component in revision total hip arthroplasty. A minimum 8.8-year and average eleven-year follow-up study.

Authors:  Roger H Emerson; William C Head; Linda L Higgins
Journal:  J Bone Joint Surg Am       Date:  2003-10       Impact factor: 5.284

10.  Clinical consequences of stress shielding after porous-coated total hip arthroplasty.

Authors:  C Anderson Engh; Anthony M Young; Charles A Engh; Robert H Hopper
Journal:  Clin Orthop Relat Res       Date:  2003-12       Impact factor: 4.176

View more
  2 in total

1.  Mechanical, in vitro antimicrobial, and biological properties of plasma-sprayed silver-doped hydroxyapatite coating.

Authors:  Mangal Roy; Gary A Fielding; Haluk Beyenal; Amit Bandyopadhyay; Susmita Bose
Journal:  ACS Appl Mater Interfaces       Date:  2012-02-28       Impact factor: 9.229

2.  Bone remodeling after a mean of 10 years in diaphyseal cortical defects repaired with femoral revision using bypass fixation of extensively porous-coated stems with high stiffness.

Authors:  Kiyokazu Fukui; Ayumi Kaneuji; Tanzo Sugimori; Toru Ichiseki; Tadami Matsumoto
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-01-04
  2 in total