The accuracy and reproducibility of a global method to correct for geometric image distortion in the x-ray imaging chain.

E Gronenschild1.   

Abstract

A method to correct for geometric image distortion in the x-ray imaging chain, so-called dewarping, has been developed. A global two-dimensional polynomial model of which the degree is optimized is used. The performance of the method has been tested in a number of experiments using images of a plate with a 1 cm spaced wire grid put against the input screen of the x-ray image intensifier (14/17/27 cm). Both offline cine film and online video images were analyzed. The accuracy of the dewarp method was derived from the acquired images and from computer-simulated distorted images. The robustness and reproducibility of the dewarp method was evaluated by means of imaging the grid in various random orientations. Three parameters describing the behavior of the algorithm were considered. One is the reproducibility of the location of a dewarped position. The second parameter is the reproducibility of the distance between two adjacent dewarped positions as a measure of the reproducibility of the size of an object under investigation. The third parameter is the reproducibility of the pixel size in the plane of the calibration plate. The major results are: the reproducibility of the location of a dewarped position was 0.01-0.04 mm for cine film and 0.04-0.07 mm for video images. The coefficient of variation of the distance between two dewarped positions was 0.04%-0.11% for cine film and 0.15%-0.18% for video images. The dewarp algorithm turned out to be fast and accurate and the distortion was removed over the whole image field down to a low random residual level. It was found that a random orientation of the grid did not affect the assessment of the distortion nor its correction. The dewarp method proved to be intrinsically robust and highly reliable. Time instability of the imaging chain was the main source of variability in the dewarp results.

Entities:  

Mesh:

Year:  1997        PMID: 9434970     DOI: 10.1118/1.598101

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  9 in total

1.  Active and passive drag: the role of trunk incline.

Authors:  P Zamparo; G Gatta; D Pendergast; C Capelli
Journal:  Eur J Appl Physiol       Date:  2009-02-18       Impact factor: 3.078

2.  A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system.

Authors:  Luis F Gutiérrez; Cengizhan Ozturk; Elliot R McVeigh; Robert J Lederman
Journal:  Med Phys       Date:  2008-03       Impact factor: 4.071

3.  Effects of distance specialization on the backstroke swimming kinematics.

Authors:  Matteo Cortesi; Silvia Fantozzi; Giorgio Gatta
Journal:  J Sports Sci Med       Date:  2012-09-01       Impact factor: 2.988

4.  Geometric calibration and correction for a lens-coupled detector in x-ray phase-contrast imaging.

Authors:  Alex George; Peter Y Chen; Alejandro Morales-Martinez; Alireza Panna; Andrew A Gomella; Eric E Bennett; Han Wen
Journal:  J Med Imaging (Bellingham)       Date:  2017-03-24

5.  In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Authors:  Luca Tersi; Arnaud Barré; Silvia Fantozzi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-11-11       Impact factor: 2.602

6.  Evaluation of RSA set-up from a clinical biplane fluoroscopy system for 3D joint kinematic analysis.

Authors:  Tommaso Bonanzinga; Cecilia Signorelli; Marco Bontempi; Alessandro Russo; Stefano Zaffagnini; Maurilio Marcacci; Laura Bragonzoni
Journal:  Joints       Date:  2016-08-18

7.  Hierarchical radial basis function networks and local polynomial un-warping for X-ray image intensifier distortion correction: a comparison with global techniques.

Authors:  P Cerveri; C Forlani; A Pedotti; G Ferrigno
Journal:  Med Biol Eng Comput       Date:  2003-03       Impact factor: 3.079

8.  Image intensifier distortion correction for fluoroscopic RSA: the need for independent accuracy assessment.

Authors:  Angela E Kedgley; Anne-Marie V Fox; Thomas R Jenkyn
Journal:  J Appl Clin Med Phys       Date:  2012-01-05       Impact factor: 2.102

9.  Six degree-of-freedom knee joint kinematics in obese individuals with knee pain during gait.

Authors:  Jing-Sheng Li; Tsung-Yuan Tsai; David T Felson; Guoan Li; Cara L Lewis
Journal:  PLoS One       Date:  2017-03-24       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.