Literature DB >> 9430576

Tibial component positioning in total knee arthroplasty: bone coverage and extensor apparatus alignment.

P Lemaire1, D P Pioletti, F M Meyer, R Meuli, J Dörfl, P F Leyvraz.   

Abstract

Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.

Entities:  

Mesh:

Year:  1997        PMID: 9430576     DOI: 10.1007/s001670050059

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  17 in total

1.  Anthropometric difference of the knee on MRI according to gender and age groups.

Authors:  Hyuksoo Han; Sohee Oh; Chong Bum Chang; Seung-Baik Kang
Journal:  Surg Radiol Anat       Date:  2015-08-08       Impact factor: 1.246

2.  Primary stability of tibial components in TKA: in vitro comparison of two cementing techniques.

Authors:  Adrian Skwara; J Figiel; T Knott; J R J Paletta; S Fuchs-Winkelmann; C O Tibesku
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-02       Impact factor: 4.342

3.  The fibular head projection is of limited use as a radiographic landmark in preoperative planning of total knee arthroplasty.

Authors:  Doerte Matziolis; Marius Meiser; Norbert Sieber; Ulf Teichgräber; Georg Matziolis
Journal:  Skeletal Radiol       Date:  2017-06-29       Impact factor: 2.199

4.  No benefit of patient-specific instrumentation in TKA on functional and gait outcomes: a randomized clinical trial.

Authors:  Matthew P Abdel; Sébastien Parratte; Guillaume Blanc; Matthieu Ollivier; Vincent Pomero; Elke Viehweger; Jean-Noël A Argenson
Journal:  Clin Orthop Relat Res       Date:  2014-03-07       Impact factor: 4.176

5.  [Diagnosis specific differences in knee joint geometry. A challenge for the correct axial implantation of long stems in total knee arthroplasty].

Authors:  M Goebel; R Burgkart; L Gerdesmeyer; P Diehl; M Schmitt-Sody; W Plötz; R Gradinger
Journal:  Orthopade       Date:  2005-11       Impact factor: 1.087

6.  Oversizing the tibial component in TKAs: incidence, consequences and risk factors.

Authors:  Michel P Bonnin; Mo Saffarini; David Shepherd; Nadine Bossard; Emmanuelle Dantony
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-01-21       Impact factor: 4.342

7.  Fluoroscopic Intraoperative Images Produce Higher Image Quality and Decrease Total Radiation Exposure Compared to Radiographic X-ray Images in Patients After Primary Total Knee Arthroplasty.

Authors:  Tilman Graulich; Julius Gerhardy; Marcus Örgel; Tarek Omar-Pacha; Mohamed Omar; Christian Krettek; Daniel Guenther
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

8.  Lateral versus medial tibial plateau: morphometric analysis and adaptability with current tibial component design.

Authors:  E Servien; M Saffarini; S Lustig; S Chomel; Ph Neyret
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-09-09       Impact factor: 4.342

9.  Influence of mediolateral tibial baseplate position in TKA on knee kinematics and retropatellar pressure.

Authors:  Arnd Steinbrück; Andreas Fottner; Christian Schröder; Matthias Woiczinski; Markus Schmitt-Sody; Tatjana Müller; Peter E Müller; Volkmar Jansson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2015-11-03       Impact factor: 4.342

10.  Rotation in total knee arthroplasty: no difference between patient-specific and conventional instrumentation.

Authors:  Sébastien Parratte; Guillaume Blanc; Thomas Boussemart; Matthieu Ollivier; Thomas Le Corroller; Jean-Noël Argenson
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-14       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.