SPECT quantification: a simplified method of attenuation and scatter correction for cardiac imaging.

J R Galt1, S J Cullom, E V Garcia.   

Abstract

The quantitative and visual interpretation of SPECT myocardial perfusion images is limited by physical factors such as photon attenuation, Compton scatter, and finite resolution effects. A method of attenuation correction is described for use in nonhomogeneous media and applied to cardiac SPECT imaging. This method, termed multiplicative variable attenuation compensation (MVAC), uses tissue contours determined from segmentation of a transmission scan to assign a priori determined attenuation coefficients to different tissue regions of the transaxial images. An attenuation correction map is then constructed using a technique inspired by Chang's method that includes regionally dependent attenuation within the chest cavity and is applied after reconstruction by filtered backprojection. Scatter correction using the subtraction of a simultaneously acquired scatter window image enables the use of narrow beam attenuation coefficients. Experimental measurements to evaluate these methods were conducted for 201Tl and 99mTc SPECT using a homomorphic cardiac phantom. Finite resolution effects were included in the evaluation of results by computer simulation of the three-dimensional activity distribution. The correction methodology was shown to substantially improve both relative and absolute quantification of uniform and nonuniform regions of activity in the phantom's myocardial wall.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1460522

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  17 in total

1.  Estimation of attenuation maps from scatter and photopeak window single photon-emission computed tomographic images of technetium 99m-labeled sestamibi.

Authors:  T S Pan; M A King; D S Luo; S T Dahlberg; B J Villegas
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

Review 2.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

3.  Application of reconstruction-based scatter compensation to thallium-201 SPECT: implementations for reduced reconstructed image noise.

Authors:  D J Kadrmas; E C Frey; B M Tsui
Journal:  IEEE Trans Med Imaging       Date:  1998-06       Impact factor: 10.048

Review 4.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.

Authors:  M A King; B M Tsui; T S Pan; S J Glick; E J Soares
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

5.  A Monte Carlo investigation of artifacts caused by liver uptake in single-photon emission computed tomography perfusion imaging with technetium 99m-labeled agents.

Authors:  M A King; W Xia; D J deVries; T S Pan; B J Villegas; S Dahlberg; B M Tsui; M H Ljungberg; H T Morgan
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

6.  Emission-based attenuation correction of myocardial perfusion studies.

Authors:  M T Madsen; P T Kirchner; M Grover-McKay; R Aktay; J S Seabold; K Rezai; G Kelly
Journal:  J Nucl Cardiol       Date:  1997 Nov-Dec       Impact factor: 5.952

Review 7.  What is the current status of quantification and nuclear medicine in cardiology?

Authors:  G Hör
Journal:  Eur J Nucl Med       Date:  1996-07

Review 8.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 1. Impact of attenuation and methods of estimating attenuation maps.

Authors:  M A King; B M Tsui; T S Pan
Journal:  J Nucl Cardiol       Date:  1995 Nov-Dec       Impact factor: 5.952

Review 9.  Multiheaded rotating gamma cameras in cardiac single-photon emission computed tomographic imaging.

Authors:  T L Faber
Journal:  J Nucl Cardiol       Date:  1994 May-Jun       Impact factor: 5.952

10.  Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease.

Authors:  P Chouraqui; S Livschitz; T Sharir; N Wainer; M Wilk; I Moalem; J Baron
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.