Surface-marker cluster design criteria for 3-D bone movement reconstruction.

A Cappozzo1, A Cappello, U Della Croce, F Pensalfini.   

Abstract

When three-dimensional (3-D) human or animal movement is recorded using a photogrammetric system, bone-embedded frame positions and orientations are estimated from reconstructed surface marker trajectories using either nonoptimal or optimal algorithms. The effectiveness of these mathematical procedures in accommodating for both photogrammetric errors and skin movement artifacts depends on the number of markers associated with a given bone as well as on the size and shape characteristics of the relevant cluster. One objective of this paper deals with the identification of marker-cluster design criteria aimed at the minimization of error propagation from marker coordinates to bone-embedded frame position and orientation. Findings allow for the quantitative estimation of these errors for any given cluster configuration and suggest the following main design criteria. A cluster made up of four markers represents a good practical compromise. Planar clusters are acceptable, provided in quasi-isotropic distribution. The root mean square distance of the markers from their centroid should be greater than ten times the standard deviation of the marker position error. The second objective of this paper deals with the identification of the optimal cluster position and orientation on the limb aimed at the minimization of error propagation to anatomical landmark laboratory coordinates. Cluster position should be selected to minimize skin movement artifacts. The longest principal axis of the marker distribution should be oriented toward the relevant anatomical landmark position.

Entities:  

Mesh:

Year:  1997        PMID: 9401217     DOI: 10.1109/10.649988

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  46 in total

1.  Foot placement alters the mechanisms of postural control while standing and reaching.

Authors:  Jason C Gillette; James J Abbas
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2003-12       Impact factor: 3.802

2.  Theoretical accuracy of model-based shape matching for measuring natural knee kinematics with single-plane fluoroscopy.

Authors:  Benjamin J Fregly; Haseeb A Rahman; Scott A Banks
Journal:  J Biomech Eng       Date:  2005-08       Impact factor: 2.097

3.  Alternative foot placements for individuals with spinal cord injuries standing with the assistance of functional neuromuscular stimulation.

Authors:  Jason C Gillette; Catherine A Stevermer; Nancy E Quick; James J Abbas
Journal:  Gait Posture       Date:  2007-05-15       Impact factor: 2.840

4.  Effects of different technical coordinate system definitions on the three dimensional representation of the glenohumeral joint centre.

Authors:  Amity Cree Campbell; J A Alderson; D G Lloyd; B C Elliott
Journal:  Med Biol Eng Comput       Date:  2009-03-13       Impact factor: 2.602

5.  THE ASSOCIATIONS BETWEEN HIP STRENGTH AND HIP KINEMATICS DURING A SINGLE LEG HOP IN RECREATIONAL ATHLETES POST ACL RECONSTRUCTION COMPARED TO HEALTHY CONTROLS.

Authors:  Jeremiah Tate; Tell Suckut; Jensen Wages; Heather Lyles; Benjamin Perrin
Journal:  Int J Sports Phys Ther       Date:  2017-06

6.  In vitro quantification of the performance of model-based mono-planar and bi-planar fluoroscopy for 3D joint kinematics estimation.

Authors:  Luca Tersi; Arnaud Barré; Silvia Fantozzi; Rita Stagni
Journal:  Med Biol Eng Comput       Date:  2012-11-11       Impact factor: 2.602

7.  EFFECTS OF THE GENIUM MICROPROCESSOR KNEE SYSTEM ON KNEE MOMENT SYMMETRY DURING HILL WALKING.

Authors:  M Jason Highsmith; Tyler D Klenow; Jason T Kahle; Matthew M Wernke; Stephanie L Carey; Rebecca M Miro; Derek J Lura
Journal:  Technol Innov       Date:  2016-09-01

8.  Pelvis and lower limb anatomical landmark calibration precision and its propagation to bone geometry and joint angles.

Authors:  U della Croce; A Cappozzo; D C Kerrigan
Journal:  Med Biol Eng Comput       Date:  1999-03       Impact factor: 2.602

9.  Design and Development of a Quasi-Passive Transtibial Biarticular Prosthesis to Replicate Gastrocnemius Function in Walking.

Authors:  Andrea M Willson; Chris A Richburg; Joseph Czerniecki; Katherine M Steele; Patrick M Aubin
Journal:  J Med Device       Date:  2020-02-18       Impact factor: 0.582

10.  Error performances of a model-based biplane fluoroscopic system for tracking knee prosthesis during treadmill gait task.

Authors:  Arnaud Barré; Kamiar Aminian
Journal:  Med Biol Eng Comput       Date:  2017-07-18       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.